loading

The accuracy of the electromagnetic flow meter meter flow meter is reduced after field use

by:Kaidi Sensors     2022-08-01
Abstract: The information on the decrease in the accuracy of the electromagnetic flow meter after the field use of the flow meter is provided by the excellent flow meter and flow meter manufacturers and quotation manufacturers. ①In a certain device, more than 20 mass flow meters are used. Its accuracy should be 0.15% according to the instrument manufacturer's sample, but the field test results are all below 0.3%. Fault inspection and analysis: After calculation, the selection is correct, and all are fully filled, and the on-site inspection is found. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the article on the reduction of accuracy after the use of electromagnetic flowmeters. ①In a certain device, more than 20 mass flow meters are used. Its accuracy should be 0.15% according to the instrument manufacturer's sample, but the field test results are all below 0.3%. Fault inspection and analysis: After calculation, the model selection is correct, and all are fully filled. The on-site inspection found that there are problems in the installation: a. The mass flowmeter is installed near the pump, and the large vibration after the pump starts will interfere with the normal operation of the flowmeter. Work. b. The instrument support column of the flowmeter is generally thin, and some mass flowmeters have only one support frame on one side. When the pipeline stress is transmitted to the instrument installation section, its support is not enough to resist the pipeline stress, which will reduce the measurement accuracy of the mass flowmeter. c. The supports of the mass flowmeter are connected together. When one of the mass flow meters is subjected to vibration interference and stress, it will inevitably be transmitted to the other flow meters, and resonance may occur. d. Some vertically installed mass flow meters cannot stabilize the heavier and larger diameter mass flow meters. Vibration in the pipeline due to the passage of fluid or stress in the pipeline will affect the correct measurement of the mass flow meter. e. The support is installed at the flow tube or connecting flange of the flowmeter, which may also cause stress to interfere with the vibration frequency of the flow tube, resulting in accuracy deviation. Troubleshooting: In summary, the reason for the decline in the accuracy of the mass flowmeter is the interference of vibration and the influence of stress. In this regard, the measures taken are: a. Keep away from the vibration pump for more than 3m. b. The position of the support is within 15D upstream and downstream of the flow meter, and two fixed support brackets are set on both sides of the meter to resist the vibration and the stress of the pipeline when the fluid flows through the pipeline (especially when there are heavy valves nearby Time). The support bracket must be removed from the meter body and be of sufficient diameter to support the weight of the mass flow meter body and piping and isolate vibration. c. When the vertical pipe diameter is large and it is difficult to make the support, the pipe where the flowmeter is installed can be designed in a horizontal form. d. The supports of each mass flow meter cannot be shared or connected together, and must be separated. e. The outlet pipeline of the instrument should preferably be higher than the pipeline behind the second support frame of the flowmeter to generate a small back pressure and avoid siphon phenomenon. f. For areas with excessive vibration, shock absorbers should be installed or other vibration reduction measures should be adopted. ②The key process in the production of sodium gum methylcellulose (CMC)——In the alkalization reaction, it is necessary to precisely control the amount of various chemical raw materials participating in the reaction. Use Fisher-Rosemount R mass flowmeter to measure the quality of hydrochloric acid, concentrated alkali and alkalized mixture. Install 3 sets of flow meters (Figure 5-12). During the test run, it was found that there was a certain error in the comparison between the measured hydrochloric acid and the process experience value. Fault inspection and analysis: After inspection, it is found that the amount of hydrochloric acid added during trial production is less than that in normal production. When the stop valve at the rear of the mass flow meter is fully opened, the hydrochloric acid cannot completely fill the medium, which affects the measurement of the instrument. Troubleshooting: slightly close the rear stop valve and re-test, the result is consistent with the process experience value. After normal production, fully open the globe valve flowmeter also works normally. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Electromagnetic flow meter meter flow meter accuracy decreases after field use'
The single most important quality you'll need as Guangdong Kaidi Energy Technology Co., Ltd. is 'stick-to-it-iveness' or grit, a combination of perseverance, patience and adaptability.
Interested in the that create such effect? Come to Kaidi level indicator to see some items.
In terms of level gauge, why is it different than other production? How does it fit a true need or desire for your requires? Is it simple to use? Make life easier?
level gauge also offers several other customized level indicator that could potentially be useful for manufacturers.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...