Home   |   INFO CENTER   |   NEWS   |  

How does the magnetic flap level gauge achieve antifreeze and heat preservation?

Home  >  INFO CENTER  >  NEWS  > 

How does the magnetic flap level gauge achieve antifreeze and heat preservation?

How does the magnetic flap level gauge achieve antifreeze and heat preservation?

2022-01-13

As a widely used liquid level detection equipment, magnetic flap liquid level gauge is widely used in food, chemical, pharmaceutical and other industries. However, in the case of freezing in winter, it is difficult to measure the liquid level with the magnetic flap level gauge working on the principle of the communicating device. At this time, the magnetic flap liquid level gauge needs to be insulated. So, how does the magnetic flap level gauge prevent freezing and keep warm? In general, there are two main methods for thermal insulation of the magnetic flap level gauge:

news-Kaidi Sensors-How does the magnetic flap level gauge achieve antifreeze and heat preservation-i

One is electric heating/electric tracing heat preservation

 

One is vacuum jacket insulation

 

The two thermal insulation methods of the magnetic flap level gauge are described as follows:

 

1. Electric heating/electrical tracing heat preservation: Electric heating/electrical tracing heat preservation is to use the resistance wire wound on the main pipeline of the magnetic flap level gauge to heat the pipeline so that the liquid in the pipeline is above the freezing point to ensure that the tank is inside the tank. The liquid will not freeze because the temperature is too low.

news-Kaidi Sensors-img

2.Vacuum jacket insulation: The vacuum jacket insulation level gauge is to install an insulation jacket outside the main body of the main pipeline, and pass heat medium such as steam to maintain the normal flow of the liquid in the main body. In this way, It is more suitable for liquid level measurement and control of easily solidified liquids. For low-boiling liquids, the stability of the liquid level can be ensured by adding refrigerants such as cold water, so that the instrument can measure the liquid level. In order to ensure the vacuum state of the vacuum jacket, we need to regularly check the vacuum state of the vacuum jacket. When the vacuum value of the vacuum jacket rises, a vacuum pump needs to be installed at the valve of the vacuum jacket to re-pump the vacuum to ensure that the detected liquid will not It freezes because the temperature is too low, so as to ensure the normal measurement of the liquid level.

news-How does the magnetic flap level gauge achieve antifreeze and heat preservation-Kaidi Sensors-i

Chat Online 编辑模式下无法使用
Leave Your Message inputting...