loading
Kaidi Sensors | Level gauge & level indicator manufacturer

Daily Inspection Guide for Smart Electromagnetic Flow Meters

Abstract: Intelligent electromagnetic flow meter daily inspection guide information is provided by excellent flow meter and flow meter production and quotation manufacturers. Guide to Daily Inspection of Smart Magnetic Flowmeters The purpose of daily inspections is to assure or prove that the magnetic flowmeter is operating in a controlled state. There are generally two methods of daily inspection, online inspection and offline inspection, mainly to verify the flow measurement value of the electromagnetic flowmeter. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the article details of the daily inspection guide for intelligent electromagnetic flowmeters. Guide to Daily Inspection of Smart Magnetic Flowmeters The purpose of daily inspections is to assure or prove that the magnetic flowmeter is operating in a controlled state. There are generally two methods of daily inspection: online inspection and offline inspection, mainly to verify whether the flow measurement value of the electromagnetic flowmeter meets and maintains the expected measurement requirements. Electromagnetic flowmeters are mainly used in flow control in industry, and the measured fluids are mostly corrosive and abrasive. In practical applications, the failures of electromagnetic flowmeters are mostly caused by corrosion leakage, insulation degradation, electrode contamination or adhesion of foreign objects. The traditional periodic maintenance inspection of electromagnetic flowmeters is to remove the flow sensor from the line for cleaning and inspection, and then perform a flow calibration. In order to reduce the damage to the lining when the flow sensor is removed from the pipeline, first measure the insulation resistance on the pipeline to infer whether there is an abnormal phenomenon, and then decide whether to remove the pipeline for inspection or real-flow flow calibration in the next step. Generally qualified (truly implementing the ISO9001 quality management system) the general inspection method of the enterprise is: (1), 1/3 is only for online inspection; (2), 1/3 is removed from the pipeline for inspection after cleaning the wetted parts; (3) ), 1/3 off-line for flow calibration. 1. One of the specific operation methods The enterprise can conduct a comprehensive inspection of the electromagnetic flowmeter once a year. The inspection contents are: appearance inspection, converter characteristic test, measurement value calibration, voltage measurement of each part, insulation resistance measurement, circuit confirmation, etc. When the instrument is checked and adjusted, it is very important to adjust the zero point due to the zero point drift (“Online zero adjustment”It is necessary to stop the flow of the measured medium, which is actually difficult to do). Therefore, the online inspection often omits the inspection involving the operation of the sensor, and only carries out the calibration of the converter, so as to compare the online inspection result with the historical data to determine whether the instrument should continue to be used, repaired or updated. For the sensor, according to the measured excitation coil insulation resistance The degree of deterioration determines whether to update or not. 2. The second specific operation method is to verify whether the electromagnetic flowmeter has any abnormal phenomenon through online inspection. Check the flow sensor and the converter separately for the pipeline that cannot stop the flow of the medium. Test the converter with an analog annunciator and other general-purpose instruments with high calibration accuracy (this depends on the accuracy of the analog annunciator), and the sensor check is based on the test electrode Wet resistance, check the excitation coil, including the insulation resistance and copper resistance of the excitation connection cable, as well as indirect methods such as checking the excitation current output by the converter and checking the magnetic field strength. For pipelines that can stop the flow of the medium, it can be entered from a preset inlet near the sensor, and the electric level and lining contamination/deposition can be checked and cleaned. 3. Inspection content Check the electromagnetic flowmeter. In addition to the zero point inspection, the flow sensor, converter and connecting cable are also carried out separately. 1. Zero point inspection of the whole machine The technical requirements for the zero point inspection of the whole machine are: the flow sensor measuring tube is full of liquid and there is no flow, which is not available in many enterprise sites and gives up the zero point inspection and adjustment of the whole machine, but can be turned to the converter. Do a separate zero check and adjustment. Technically speaking, this has practical significance only after the sensor inspection is completed and the insulation resistance of the excitation circuit and the signal circuit of the sensor is guaranteed to be normal (both including cables), otherwise the whole machine cannot run normally. Usually the single zero point of the converter is a negative value, and the value is also small; if its absolute value is greater than 5% of the full scale, it needs to be checked first, and then adjusted after confirming the cause. Under normal circumstances, the difference between the zero point of the electromagnetic flowmeter and the individual zero point of the converter is less than 1%. There are many cases where the zero difference value greater than 5% is caused by the user's incorrect zero adjustment operation when the pipeline valve is not closed properly. 2. Inspection of connecting cables The inspection content is to check the continuity and insulation resistance of each core of the signal line and the excitation line, and to check whether the grounding of each shielding layer is in good condition. 3. Converter inspection The inspection content is to use the general instrument and the analog signal device matching the flowmeter model to replace the sensor to provide the flow signal for zero adjustment and calibration. Calibration includes zero check and adjustment, setpoint check, field current measurement, current/frequency output check, etc.

Technology is a foundational component of today's fast-paced business environment. Guangdong Kaidi Energy Technology Co., Ltd. who are digital natives are especially equipped to harness technology's power to establish, promote and grow our businesses.

If you would like to learn more about , be sure to visit Kaidi level indicator for more information!

Guangdong Kaidi Energy Technology Co., Ltd. is a new company that provides expertise in search marketing solutions for business on a worldwide basis.

GET IN TOUCH WITH Us
recommended articles
INFO CENTER FAQ NEWS
Introduction:

Tank operations in various industries require a high level of precision, efficiency, and safety.
For industries that rely on large storage tanks to store liquids or gases, monitoring the levels and conditions of these tanks is vital for operational efficiency and safety.
Conveyor Belt Safety Switches: Ensuring Worker Safety

Conveyor belts are an essential part of many industries, from manufacturing to logistics.
Gas grills have become an essential part of many households, providing a convenient way to enjoy delicious meals in the comfort of your backyard.
Flow transmitters are essential components in various industries, providing accurate measurements of fluid flow rates.
Level Instrumentation: The Future of Measurement Technology

Level instrumentation plays a crucial role in various industries, providing accurate measurements of liquids, solids, and gases in tanks, silos, and pipelines.
Level Instruments: Essential for Process Optimization

Level instruments play a crucial role in ensuring the smooth operation and efficiency of industrial processes.
Radar Level Meters: How They Enhance Measurement Accuracy

Radar level meters are advanced devices used to accurately measure levels of liquids and solids in various industrial applications.
3D Radar Level Scanners: Applications in Mining

Mining operations require precise and accurate monitoring of the levels of materials such as ore, coal, and other resources stored in silos, bunkers, and stockpiles.
Ultrasonic Level Meters: Benefits in Chemical Processing

Ultrasonic level meters have revolutionized the way chemical processing plants monitor and control liquid levels in various tanks and vessels.

CONTACT US

Attn: Mr. Joe Zou
Email:info86kd@gmail.com | info@kaidi86.com
Tel: +86 756 8652289
Fax: +86 756 8652290
Mob: +86 18198790863 (whatsapp/Wechat Same Number)
Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

BETTER TOUCH BETTER BUSINESS

Contact Sales at KAIDI level gauge manufacturer.

Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
Customer service
detect