Field Calibration Method of Intelligent Electromagnetic Flow Meter

by:Kaidi Sensors     2022-08-27
Abstract: The information on the field calibration method of the intelligent electromagnetic flowmeter meter is provided by the excellent flowmeter and flowmeter production and quotation manufacturers. When Huai'an Yuanneng Instrument Co., Ltd. produces electromagnetic flowmeters, its accuracy is already calibrated by the calibration line. However, in the field of use, the operation of the instrument may fail due to environmental conditions, fluid characteristics, and the instrument itself, such as damage to components. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following is the details of the article on the field calibration method of intelligent electromagnetic flowmeters. When Huai'an produces the electromagnetic flowmeter, its accuracy is already calibrated by the calibration line. However, in the field of use, due to environmental conditions, fluid characteristics, and the instrument itself, such as damage to components, etc., it is necessary to perform a routine on-site calibration for the flowmeter after long-term use. Since the sensor of the intelligent electromagnetic flowmeter is installed on the pipeline, it is difficult to remove it and send it to the calibration line for inspection. At present, within the range of flow measurement, the state and local governments have not yet implemented regulations and other regulations for online inspection of large-diameter flowmeters under field conditions. Regulatory documents. In order to ensure the accuracy and reliability of the electromagnetic flowmeter after fault repair and long-term use, without affecting daily production, there are 6 methods for on-site calibration of the electromagnetic flowmeter: 1. Conduct a safety insulation test on the electromagnetic flowmeter excitation coil, Should be greater than 20MΩ. 2. The copper resistance test of the excitation coil of the electromagnetic flowmeter should be the same as the original factory value (when the ambient temperature is the same). 3. Test the electrode-to-ground resistance of the electromagnetic flowmeter sensor. If the resistance value is between 2 and 20kf, accompanied by charging and discharging, and the resistances of the two electrodes are similar, it is considered good. 4. Test the excitation current of the electromagnetic flowmeter converter, observe the value of its output and the original current of the converter, and the error does not exceed ±0.25mA. 5. Test the analog output and frequency output of the electromagnetic flowmeter converter, observe the linear change, and calculate the maximum linear error, which should not exceed ±0.5%. 6. For electromagnetic flowmeters above DN1200mm, the push-level NB should be tested, and the current error should not exceed 12mA. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Intelligent electromagnetic flow meter field calibration method'
At the same time, as the recent research of KAIDI shows, the benefits of improved productivity and firm performance can make implementing basic management practices worth it.
If you are looking for an excellent service in the UK then you can go to Guangdong Kaidi Energy Technology Co., Ltd.. They have almost everything what you might require for your customized level indicator.
Making a few technical tweaks to the way you structure and distribute level gauge could be the difference between an engaging, thought-provoking product and a perfunctory one.
Our company is professional in selling level gauge as well as providing a series of relevant services.