loading
Kaidi Sensors | Level gauge & level indicator manufacturer
Kaidi KD-908 26GHz Radar Level Meter 1
Kaidi KD-908 26GHz Radar Level Meter 2
Kaidi KD-908 26GHz Radar Level Meter 3
Kaidi KD-908 26GHz Radar Level Meter 4
Kaidi KD-908 26GHz Radar Level Meter 5
Kaidi KD-908 26GHz Radar Level Meter 1
Kaidi KD-908 26GHz Radar Level Meter 2
Kaidi KD-908 26GHz Radar Level Meter 3
Kaidi KD-908 26GHz Radar Level Meter 4
Kaidi KD-908 26GHz Radar Level Meter 5

Kaidi KD-908 26GHz Radar Level Meter

26GHz Radar Level Meter
5.0
Application:
Rivers, Lakes, Shoal
Measuring Range::
30~70meters
Protection Grade::
IP67 / IP65
Accuracy::
± 3mm
Frequency:
26 GHz
Process Pressure::
Normal pressure
Process Temperature::
-40℃ ~ 100℃
Process Connection::
Thread G1½ A″ /Frame /Flange
Outer Covering::
Aluminum /Plastic /Stainless steel
Power supply:
(6 - 24V) DC / Four-wire 、 24V DC / Two wire
Signal output:
4~20mA/HartTwowire(24VDC)
MOQ:
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
design customization

    oops...!

    no product data.

    Go to homepage

    Characteristics of water conservancy industry application:

    Ø  Radar level meter adopts a recommended industry emission frequency of 26GHz, so it has beam angle is small, concentrated energy, has stronger anti-interference ability and greatly improves the precision and reliability of measurement.

    Ø  Small antenna size, easy to install and dustproof cover antenna protection device.

    Ø  Light weight about 1KG, easy to install.

    Ø  The measurement range of up to 70 meters, covering a large reservoir water level measurement.

    Ø  With a variety of output circuit interface and data acquisition system.

    Ø  The pulse working mode, radar level meter transmit power is very low, no harm to human body and environment.

    908 :

    ApplicationRivers, Lakes, Shoal
    Measuring   Range: 30 meters
    Process   ConnectionThread G1½ A /Frame /Flange
    Process  Temperature -40 ~ 100
    Process   Pressure:Normal pressure
    Accuracy ± 3mm
    Protection   GradeIP67 / IP65
    Frequency   Range:26 GHz
    The signal   Output:  RS485 / Modbus  ( 6~24V  DC) 4~20mA / Hart  Two  wire ( 24V DC) 
    Power Supply   : (6 - 24V)   DC  / Four-wire    24V DC / Two  wire
    The Scene   DisplayOptional
    Outer Covering   : Aluminum /Plastic   /Stainless steel 
    Outer   Covering: Aluminum /   Plastic /Single chamber



    909 :

    ApplicationRivers, Lakes, Shoal
    Measuring   Range: 70 meters
    Process   ConnectionThread G1½ A /Frame /Flange
    Process  Temperature -40 ~ 100
    Process   Pressure:Normal pressure
    Accuracy ± 10mm
    Protection   GradeIP67 / IP65
    Frequency   Range:26 GHz
    The signal   Output:  RS485 / Modbus  ( 6~24V  DC) 4~20mA / Hart  Two  wire ( 24V DC) 
    Power Supply   : (6 - 24V)   DC  / Four-wire    24V DC / Two  wire
    The Scene   DisplayOptional
    Outer Covering   : Aluminum /Plastic   /Stainless steel 
    Outer   Covering: Aluminum /   Plastic /Single chamber

    1611813813.jpg


    1.   Installation

    l  Preparation before installation:

    Ø  Please pay attention to the following matters, to ensure that the instrument can be installed correctly:

    Ø  Please reserve enough space for installation.

    Ø  Please avoid installing occasions strong vibration.

    l  Illustration and installation position

    Note: Radar antenna microwave pulse, have a certain emission angle. From the lower end of the antenna to be measured between the surface of the medium, and a transmitter shall be no obstruction in the region of the microwave beam radiation. Therefore, the installation should be avoided as far as possible shelter facilities, shall be carried out "false echo study" when necessary. Also note that when installing devices: the highest level measured shall enter blind; instrument must be connected to the earth, increasing the lightning protection measures; outdoor shade should be taken, rain measures.1611814741(1).png

    Note: Radar antenna microwave pulse, have a certain emission angle. From the lower end of the antenna to be measured between the surface of the medium, and a transmitter shall be no obstruction in the region of the microwave beam radiation. Therefore, the installation should be avoided as far as possible shelter facilities, shall be carried out "false echo study" when necessary. Also note that when installing devices: the highest level measured shall enter blind; instrument must be connected to the earth, increasing the lightning protection measures; outdoor shade should be taken, rain measures.


    2. The Electrical  Connection

    Power Supply voltage


    RS485 /   Modbuspower supply   and Modbus signal lines separated respectively using a shielded cable, the   power supply voltage range of see technical data.
    (4~20)mA/HART   (Two wire system)       The   power supply and the output current signal sharing a two core shield cable.   The supply voltage range see technical data. For intrinsically safe type must   be a safety barrier between the power supply and the instrument.



    Connection mode

    l  The RS485/Modbus wiring diagram as follows:

    1611814954(1).png

    l  24V two wire wiring diagram as follows:

    1611815011(1).png

    Protection grade

    This instrument meets the protection grade IP66/67 requirements,  please ensure the waterproof cable sealing head.

    1611815093(1).png


    How to install to meet the requirements of IP67:

    Please make sure that the sealing head is not damaged.

    Please make sure that the cable is not damaged.

    Please make sure that the cable for use with electrical connection specification.

    Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the

    Tighten the cable seal head, see the

    Please electrical interface will not use blind plug tight, see the


    3.   Structure  Size  (Unit: mm)

    lThe Outer Covering:

    1611816566(1).png

    l  Appearance  size:

    908 : 

    1611816646(1).png

    909 :

    1611816723(1).png

     Connection 

    ²  Standard bracket

    ²  With rain cover bracket

    ²  Thread G1½ "A connection

    ²  G1½ mounting base connection

    1611816851(1).png

    4.   Technical   Parameters

    The outer shell  
    The seal between the shell and the shell cover                 Silicone rubber
    Casing   window                                                                   Polycarbonate
    The ground   terminal                                                           Stainless steel
    The power supply voltage
    Four wire   system(624) V DC / RS485    Modbus  / Power dissipation   90mW
    Two wire   systemDC 24V /  4~20mA     / Power dissipation  0.75W
    The cable parameters 
    Cable entrance   / plug           1    M20xl.5 cable entrance

     1    blind plug
    Terminal                               Conductor cross section1.0mm²  
    Output parameters
    The output signal                              RS485  Modbus    (6~24V  DC)
    4~20mA /   Hart  Two  wire ( 24V DC)
    Communication   protocol                  Modbus  control / HART
    Resolution                                        1.6μA
    Fault   signal                                       Constant current   output; 20. 5mA

    22mA 

    3.9mA
    The integral   time                              (0 ~ 36) s,   adjustable
    Blind   area                                 the ends of the   antenna
    The maximum distance measurement      
    90830 meters  
    90970 meters  
     Microwave frequency                                              26GHz
    The   measurement interval       about 1 second   (depending on the parameter settings)
    Adjust the   time                         about 1 second   (depending on the parameter settings)
    Display   resolution                   1 mm
    Working storage and transportation temperature                          (-4070) 
    Process temperature (the temperature of the antenna part   (-40100)
    Pressure                                    Normal atmospheric   pressure
    Seismic                                       Mechanical vibration   l0m/s², (10 ~ 150) Hz

    Meter  Linearity

    908 :


    Emission angle                 Depending on the size of the antenna

    -76mm                          12°

    -96mm                          18°

    Precision                          See chart


    1611817551(1).png

    909 :


    Emission angle                 Depending on the size of the antenna

    -76mm                          12°

    -96mm                          18°

    -121mm                         6°

    Precision                          See chart

    1611817619(1).png

    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs.
    Related Products

    CONTACT US

    Attn: Mr. Joe Zou
    Email:info86kd@gmail.com | info@kaidi86.com
    Tel: +86 756 8652289
    Fax: +86 756 8652290
    Mob: +86 18198790863 (whatsapp/Wechat Same Number)
    Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

    BETTER TOUCH BETTER BUSINESS

    Contact Sales at KAIDI level gauge manufacturer.

    Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
    Customer service
    detect