Characteristics of water conservancy industry application:
Ø Radar level meter adopts a recommended industry emission frequency of 26GHz, so it has beam angle is small, concentrated energy, has stronger anti-interference ability and greatly improves the precision and reliability of measurement.
Ø Small antenna size, easy to install and dustproof cover antenna protection device.
Ø Light weight about 1KG, easy to install.
Ø The measurement range of up to 70 meters, covering a large reservoir water level measurement.
Ø With a variety of output circuit interface and data acquisition system.
Ø The pulse working mode, radar level meter transmit power is very low, no harm to human body and environment.
908 :
Application: | Rivers, Lakes, Shoal |
Measuring Range: | 30 meters |
Process Connection: | Thread G1½ A″ /Frame /Flange |
Process Temperature: | -40℃ ~ 100℃ |
Process Pressure: | Normal pressure |
Accuracy: | ± 3mm |
Protection Grade: | IP67 / IP65 |
Frequency Range: | 26 GHz |
The signal Output: | RS485 / Modbus ( 6~24V DC) 、 4~20mA / Hart Two wire ( 24V DC) |
Power Supply : | (6 - 24V) DC / Four-wire 、 24V DC / Two wire |
The Scene Display | Optional |
Outer Covering : | Aluminum /Plastic /Stainless steel |
Outer Covering: | Aluminum / Plastic /Single chamber |
909 :
Application: | Rivers, Lakes, Shoal |
Measuring Range: | 70 meters |
Process Connection: | Thread G1½ A″ /Frame /Flange |
Process Temperature: | -40℃ ~ 100℃ |
Process Pressure: | Normal pressure |
Accuracy: | ± 10mm |
Protection Grade: | IP67 / IP65 |
Frequency Range: | 26 GHz |
The signal Output: | RS485 / Modbus ( 6~24V DC) 、 4~20mA / Hart Two wire ( 24V DC) |
Power Supply : | (6 - 24V) DC / Four-wire 、 24V DC / Two wire |
The Scene Display | Optional |
Outer Covering : | Aluminum /Plastic /Stainless steel |
Outer Covering: | Aluminum / Plastic /Single chamber |
1. Installation
l Preparation before installation:
Ø Please pay attention to the following matters, to ensure that the instrument can be installed correctly:
Ø Please reserve enough space for installation.
Ø Please avoid installing occasions strong vibration.
l Illustration and installation position
Note: Radar antenna microwave pulse, have a certain emission angle. From the lower end of the antenna to be measured between the surface of the medium, and a transmitter shall be no obstruction in the region of the microwave beam radiation. Therefore, the installation should be avoided as far as possible shelter facilities, shall be carried out "false echo study" when necessary. Also note that when installing devices: the highest level measured shall enter blind; instrument must be connected to the earth, increasing the lightning protection measures; outdoor shade should be taken, rain measures.
Note: Radar antenna microwave pulse, have a certain emission angle. From the lower end of the antenna to be measured between the surface of the medium, and a transmitter shall be no obstruction in the region of the microwave beam radiation. Therefore, the installation should be avoided as far as possible shelter facilities, shall be carried out "false echo study" when necessary. Also note that when installing devices: the highest level measured shall enter blind; instrument must be connected to the earth, increasing the lightning protection measures; outdoor shade should be taken, rain measures.
2. The Electrical Connection
Power Supply voltage
RS485 / Modbus | power supply and Modbus signal lines separated respectively using a shielded cable, the power supply voltage range of see technical data. |
(4~20)mA/HART (Two wire system) | The power supply and the output current signal sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument. |
Connection mode
l The RS485/Modbus wiring diagram as follows:
l 24V two wire wiring diagram as follows:
Protection grade
This instrument meets the protection grade IP66/67 requirements, please ensure the waterproof cable sealing head.
How to install to meet the requirements of IP67:
Please make sure that the sealing head is not damaged.
Please make sure that the cable is not damaged.
Please make sure that the cable for use with electrical connection specification.
Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the①
Tighten the cable seal head, see the②
Please electrical interface will not use blind plug tight, see the③
3. Structure Size (Unit: mm)
lThe Outer Covering:
l Appearance size:
908 :
909 :
l Connection
² Standard bracket
² With rain cover bracket
² Thread G1½ "A connection
² G1½ mounting base connection
4. Technical Parameters
The outer shell | |
The seal between the shell and the shell cover | Silicone rubber |
Casing window | Polycarbonate |
The ground terminal | Stainless steel |
The power supply voltage | |
Four wire system | (6~24) V DC / RS485 Modbus / Power dissipation 90mW |
Two wire system | DC 24V / 4~20mA / Power dissipation 0.75W |
The cable parameters | |
Cable entrance / plug | 1 M20xl.5 cable entrance |
1 blind plug | |
Terminal | Conductor cross section1.0mm² |
Output parameters | |
The output signal | RS485 Modbus (6~24V DC) |
4~20mA / Hart Two wire ( 24V DC) | |
Communication protocol | Modbus control / HART |
Resolution | 1.6μA |
Fault signal | Constant current output; 20. 5mA |
22mA | |
3.9mA | |
The integral time | (0 ~ 36) s, adjustable |
Blind area | the ends of the antenna |
The maximum distance measurement | |
908 | 30 meters |
909 | 70 meters |
Microwave frequency | 26GHz |
The measurement interval | about 1 second (depending on the parameter settings) |
Adjust the time | about 1 second (depending on the parameter settings) |
Display resolution | 1 mm |
Working storage and transportation temperature | (-40~70)℃ |
Process temperature (the temperature of the antenna part | (-40~100)℃ |
Pressure | Normal atmospheric pressure |
Seismic | Mechanical vibration l0m/s², (10 ~ 150) Hz |
l Meter Linearity
908 :
Emission angle Depending on the size of the antenna
-¢76mm 12°
-¢96mm 18°
Precision See chart
909 :
Emission angle Depending on the size of the antenna
-¢76mm 12°
-¢96mm 18°
-¢121mm 6°
Precision See chart
We are here to help you! If you close the chatbox, you will automatically receive a response from us via email. Please be sure to leave your contact details so that we can better assist