loading
Home  >  PRODUCT  >  Level Instrument  >  Radar Level Meter  > 

Kaidi KD-FMF15 FM 120GHz 35 meters Radar Level Gauge for high temperature and high pressure

这里可以自定义设置
product-Kaidi Sensors-Kaidi KD-FMF15 FM 120GHz 35 meters Radar Level Gauge for high temperature and
product-Kaidi KD-FMF15 FM 120GHz 35 meters Radar Level Gauge for high temperature and high pressure--1
product-Kaidi Sensors-img-1
product-Kaidi Sensors-img-1
product-Kaidi Sensors-img-1
product-Kaidi Sensors-img-1
Kaidi KD-FMF15 FM 120GHz 35 meters Radar Level Gauge for high temperature and high pressure
Application:
igh temperature and high pressure and other environmental liquids
Measuring Range:
0.1m~35m
Protection Grade:
IP67
Accuracy:
±2mm
Frequency:
123GHz
Process Pressure:
-0.1~2.5MPa
Process Temperature:
-40~200℃
Process Connection:
flange ≥DN80
Explosion proof certification:
Exia ⅡC T6 Ga / Exd IIC T6 Gb
Outer Covering:
two-wire system 4...20mA/HART protocol/four-wire system 4...20mA /RS485 Modbus
MOQ
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
参数暂无数据
B站不支持优惠卷

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障
PRODUCT OVERVIEW

The KD-FMF series sensor is a 120G frequency modulation radar type level measuring instrument with a measuring distance of up to 35 meters. The antenna is further optimized, and the new and fast microprocessor can perform higher-speed signal analysis and processing, so that the meter can be used for measuring high temperature and high pressure and other environmental liquids.


product-Kaidi KD-FMF15 FM 120GHz 35 meters Radar Level Gauge for high temperature and high pressure--2

PRODUCT PRINCIPLE

The general principle of the FM continuous wave radar level gauge is that the radar emits electromagnetic waves on the top of the tank, and the electromagnetic waves are received by the radar after being reflected by the medium. The frequency difference δ f between the received signal and the transmitted signal is proportional to the distance R from the surface of the medium. : R= C (speed) *δ f (frequency difference) /2/K (frequency modulation slope). Because the speed of light C and the frequency modulation slope K are known, the frequency difference δ f can be estimated to obtain the distance R of the material surface at the radar installation position, and then through the known total height of the tank, subtract the spatial distance from the radar to the material surface ( Referred to as the air height), the height of the material level is obtained.


product-Kaidi Sensors-img-2

PROTECTION GRADE

This meter fully meets the requirements of protection class IP66/67, please ensure the waterproofness of the cable sealing head. As shown

How to ensure that the installation meets the requirements of IP67:

Make sure that the sealing head is not damaged.

Make sure that the cable is not damaged.

Make sure that the cables used meet the requirements of the electrical connection specifications.

Before entering the electrical interface, bend the cable downward to ensure that water does not flow into the housing, see ①

Please tighten the cable sealing head, see ②

Please block the unused electrical interfaces with blind plugs, see ③


product-Kaidi Sensors-img-2

PRODUCT SPECIFICATION

product-Kaidi Sensors-img-2

Measuring medium: liquid

Measuring range: 0.1m~35m

Process connection: flange ≥DN80

Process temperature: -40200℃

Process pressure: -0.12.5MPa

Accuracy: ±2mm

Protection level: IP67

Frequency range: 123GHz

Power supply: two-wire system (DC24V)/four-wire system (DC12V~24V)/four-wire system (AC220V)

Explosion-proof grade: Exia ⅡC T6 Ga / Exd IIC T6 Gb

Shell: Aluminum/Plastic/Stainless Steel

Signal output: two-wire system 4...20mA/HART protocol/four-wire system 4...20mA /RS485 Modbus


APPEARANCE OF SIZE


product-Kaidi Sensors-img-2

Standard Type


product-Kaidi Sensors-Kaidi KD-FMF15 FM 120GHz 35 meters Radar Level Gauge for high temperature and -2

High Temperature Type


TECHNICAL PARAMETERS


Process connectionFlange
Material304 stainless steel, PP
ShellSeal between housing and housingSilicone Rubber
Shell windowPolycarbonate
Ground terminalStainless steel
Supply voltageFour-wire systemStandard12~24V DC
Power consumptionmax80mA DC24V/2W
Allow ripple100HzUss1V
100~100KHzUss10mV
Double chamber housing(198~242)V ACFour-wire system
100V ACFour-wire system
Cable parametersCable entry/plug1 M20x1.5 cable entry
1 blind plug M20×15
Ground terminalConductor cross section 2.5mm2
Output parametersoutput signal4~20mA/RS485Modbus
Resolution1mm
Fault signalCurrent output unchanged; 20.5mA; 22mA; 3.9mA
Integration time(0~20)s, adjustable
Blind spot0.1m/0.2m/0.3m
Maximum measurement interval150 meters
Measuring distanceAbout 1 second (depending on parameter settings)
Adjust the timeAbout 1 second (depending on parameter settings)
Adjust time, working storage and transportation temperature-40~80)℃
Process temperatureKD-FMF11-40~80
KD-FMF12-40~110
KD-FMF13-40~110
KD-FMF15-40~200
KD-FMF21-40~110
Relative humidity95%
PressureMax2.5MPa
ShockproofMechanical vibration 10m/s2, (10~150)Hz


INSTRUMENT LINEARITY


product-Kaidi KD-FMF15 FM 120GHz 35 meters Radar Level Gauge for high temperature and high pressure--3

INSTALLATION REQUIREMENTS

When installing the instrument, avoid installing it above the inlet, and try to avoid all kinds of objects that affect the signal, such as stirring paddles, etc.


product-Kaidi Sensors-img-3

● Under extremely complicated working conditions, the instrument can work normally if there is no obstacle in the area of 500px radius with the radar installation point as the center.


product-Kaidi Sensors-img-3


product-Kaidi Sensors-img-3

Under extremely complicated working conditions, the instrument can work normally if there is no obstacle in the area of 500px radius with the radar installation point as the center.


PRODUCT SHOW

product-Kaidi Sensors-img-3

该产品后台详情无内容
Product Message
社媒暂无评论
Chat Online 编辑模式下无法使用
Leave Your Message inputting...