Application:
All kinds of corrosive liquid
Measuring Range::
10m
Protection Grade::
IP67
Accuracy::
±5mm
Frequency:
26GHz
Process Pressure::
(-0.1~0.3)Mpa
Process Temperature::
-40℃~130℃
Process Connection::
Thread, Flange
Explosion proof certification:
ExiaⅡCT6Ga/ExdⅡCT6Gb
Outer Covering::
Aluminum / Plastic / Stainless steel
Power supply:
Two-wire system (DC24V) Four-wire system (DC24V/AC220V)
Signal output:
(4~20)mA/HART
MOQ:
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
design customization

    oops...!

    no product data.

    Go to homepage

    I. Product  Overview

    This series of radar level meter adopted 26G high frequency radar sensor, the maximum measurement range can reach up to 10 meters. Antenna is optimized further processing, the new fast microprocessors have higher speed and efficiency can be done signal analysis, the instrumentation can be used for reactor, solid silo and very complex measurement environment.

    • Principle

    Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous).

    product-Kaidi Sensors-img

      Range set

    B    Low adjustment

    C    High

                      D    Blind area

    Datum measurement:  Screw thread bottom or the sealing surface of the flange.

    Note: Make sure the radar level meter the highest level cannot enter the measuring blind area (Figure D shown below).


    • The characteristics of 26G radar level meter:

    Ø  Small antenna size, easy to install; Non-contact radar, no wear, no pollution.

    Ø  Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure changes.

    Ø  Serious dust environment on the high level meter work has little effect.

    Ø  A shorter wavelength, the reflection of solid surface inclination is better.

    Ø  Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.

    Ø  The measuring range is smaller, for a measurement will yield good results.

    Ø  High signal-to-noise ratio, the level fluctuation state can obtain better performance.

    Ø  High frequency, measurement of solid and low dielectric constant of the best choice.


    II. Product  Introduction

    901 Model 

    product-Kaidi Sensors-img


    ApplicationAll kinds of   corrosive liquid
    Measuring   Range: 10 meters
    Process Connection Thread, Flange
    Process  Temperature -40~130
    Process Pressure -0.1~0.3 Mpa
    Accuracy ± 5mm     
    Protection Grade IP67  
    Frequency Range 26GHz 
    Supply2-wireDC24V/ 4-wireDC24V   /AC220V
    Signal Output4... 20mA /HART2-wire / 4-wireRS485/ Modbus
    Outer CoveringAluminum / Plastic /   Stainless steel
    Explosion-proof   GradeExiaC T6 Ga/ Exd C T6 Gb

    III. The  Installation Requirements

    • Installation guide:

    The 901 radar level gauge can be mounted using a threaded connection and flange connection, typically used for the measurement of corrosive liquids in smaller tanks. The instrument is installed at 1/4 or 1/6 of the diameter and the PTFE rod is to be inserted into the measuring tank.

    Note: The minimum distance from the tank wall should be 300mm.

    Note:   datum

        ②The container center or axis of symmetry

    product-Kaidi Sensors-imgproduct-Kaidi Sensors-Kaidi - 26GHz Radar Level Meter Model 901-img

    • The top conical tank level, can be installed at the top of the tank is intermediate, can guarantee the measurement to the conical bottom.

    product-Kaidi Sensors-img

    Typical installation errors

    Ø  Conical tank cannot be installed above the feed port.

    Note: outdoor installation should adopt sunshade. 

    product-Kaidi - 26GHz Radar Level Meter Model 901-Kaidi Sensors-img

    Ø  The instrument cannot be installed in the arched or domed roof intermediate. In addition to produce indirect echo is also affected by the echoes. Multiple echo can be larger than the real value of signal echo, because through the top can concentrate multiple echo. So cannot be installed in a central location. 

    product-Kaidi Sensors-img-1

    Ø  There are obstacles affecting measurement needed reflection plate.

    product-Kaidi Sensors-img-1

    • Height of nozzle:

    Antenna extends into the tank at least 10mm distance.

    product-Kaidi Sensors-img-1

    IV. The Electrical Connection

    • The power supply voltage:

    (4~20)mA/HART (Two wire system)    The power supply and the output current signal sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument.

    (4~20)mA/HART (Four wire system)   Separate power supply and the current signal, respectively using a two-core shielded cable. The supply voltage range see technical data.

    RS485 / Modbus                                  Power supply and Modbus signal line separated  respectively using a two-core shielded cable, the power supply voltage range see technical data.

    • Connection  mode:

    Ø  24V two wire wiring diagram as follows:

    product-Kaidi Sensors-Kaidi - 26GHz Radar Level Meter Model 901-img-1

    Ø  6~24V RS485/Modbus wiring diagram as follows:

    product-Kaidi Sensors-img-1

    • Explosion Proof Connection

    The intrinsic safety version sensors (Exia IIc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia IIc T6.

    A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: Exia IIC, voltage of power supply: 24V DC±5%, short-circuit current: 135mA, operating current: 4...20mA.

    All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor0.1μF/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used.

    product-Kaidi - 26GHz Radar Level Meter Model 901-Kaidi Sensors-img-1

    product-Kaidi Sensors-img-2

    • Safety  instructions:

    Ø  Please observe the local electrical code requirements!

    Ø  Please comply with local requirements for personnel health and safety regulations.

    All electrical components of instrument operation must be completed by the formal training of professionals.

           Ø  Please check the instrument nameplate to provide product specifications meet your requirements. Please make sure that the power supply voltage and instrument nameplate on the requirements.

    • Protection  grade:

    This instrument meets the protection class IP66/67 requirements, please ensure the waterproof cable sealing head. The following diagram:

    product-Kaidi Sensors-img-2

    How to install to meet the requirements of IP67:

    Please make sure that the sealing head is not damaged.

    Please make sure that the cable is not damaged.

    Please make sure that the cable for use with electrical connection specification.

    Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the

    Tighten the cable seal head, see the

    Please electrical interface will not use blind plug tight, see the

    V. Instrument Commissioning

    • There are three kinds of debugging method:

      1) Display / Keyboard  

      2) Host debugging  

      3) HART handheld programmer

    • Display / Keyboard:

    Please debug the instrumentation by four buttons on the display screen. There are three debug menu languages optional. After debugging is generally used only for display, through the glass window can read measured value very clearly.

    Display / Keyboard

    product-Kaidi Sensors-img-2

    Liquid crystal display(LCD) 

    The key

    • PC debugging:

    Connected to PC by HART

    product-Kaidi Sensors-Kaidi - 26GHz Radar Level Meter Model 901-img-2

      RS232 interface or USB interface                     

      Radar level meter

    HART adapter

      250 Ω resistor

    HART  handheld  programmer:

    product-Kaidi Sensors-img-2

    HART handheld programmer

      Radar level meter

      250 Ωresistor

    VI. Structure Size   (Unit: mm)

    The outer shell:

    product-Kaidi - 26GHz Radar Level Meter Model 901-Kaidi Sensors-img-2

    • Appearance  size:

    901 

    product-Kaidi Sensors-img-3

    • Flange  type:

    product-Kaidi Sensors-img-3

    VII. Technical Parameters

    Process Connection             Thread G1½″A / Thread 1½″ NPT /  Flange

    Antenna Material                   Stainless Steel  /  PTFE

    The outer shell 

    The seal between the shell and the shell cover                 Silicone rubber

    Casing window                                                                   Polycarbonate

    The ground terminal                                                           Stainless steel

     

    The power supply voltage

    Two wire system              

      The standard type                   (16 ~ 26) V DC

    Intrinsically safe                      (21.6 ~ 26.4) V DC  

    Power dissipation                    max 22.5mA / 1W    

    Allowable ripple

    - <100Hz                                   Uss100K) Hz                      Uss

    Flameproof                            (22.8 ~ 26.4) V DC       2-wire system

    (198 ~242)V AC   4-wire system / 110V AC    4-wire system

     

    The cable parameters

    Cable entrance / plug           1  M20xl.5 cable entrance

                                                 1  blind plug

    Terminal                               Conductor cross section 2.5mm² 

     

    Output parameters

    The output signal                              (4 ~ 20) mA/RS485

    Communication protocol                   HART

    Resolution                                        1.6μA

    Fault signal                                       Constant current output; 20. 5mA

    22mA

    3.9mA

    The integral time                               (0 ~ 36) s, adjustable

     

    Blind area                                 the ends of the antenna

    The maximum distance measurement                 

    901                  10 meters   Liquid type

    Microwave frequency                    26GHz

    Communication interface               HART communication protocol

    The measurement interval       about 1 second (depending on the parameter settings)

     

    Adjust the time                          about 1 second (depending on the parameter settings)

    Display resolution                    1 mm

    Working storage and transportation temperature                          (-40100)

    Process temperature (the temperature of the antenna part)            (40130)

    Pressure                                     Max.4MPa

    Seismic                                       Mechanical vibration l0m/s², (10 ~ 150) Hz 


    VIII. Meter  Linearity

    901

    Emission angle 20° Precision See chart

    product-Kaidi Sensors-img-3


    VIV. Product  Model  Selection

    901

    License

    P    Standard (Non-explosion-proof)

    I     Intrinsically safe (Exia IIC T6 Ga)

    G    Flameproof (Exd  IIC T6 Gb)

    Antenna Type / Material / Temperature

    F Sealing horn / PTEE / -40... 130

    Process Connection / Material

    G   Thread G1½A

    N   Thread 1½″ NPT

     A    Flange  DN50 /PP          

     B    Flange  DN80 /PP

    C    Flange  DN100 /PP

    Y    Special custom

    The Outlet  Pipe  Length of the Container

    A    Outlet pipe 100mm         

    B    Outlet pipe 200mm

    The  Electronic Unit

    3   (4~20) mA / 24V DC / HART two wire system

    4   (4~20) mA / 220V AC / HART four wire system

    5    RS485  Modbus / 6~24V/ Four wire system

    Outer Covering / Protection  Grade

    L    Aluminum / Single chamber / IP67

    H    Aluminum / Double chamber / IP67

    G   Plastic / Single chamber / IP65

    K   Stainless steel / Single chamber / IP67

    Cable Line

    M    M 20x1.5

    N   ½NPT

    Field Display/The Programmer

    A   With

    X   Without


    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs.
    Related Products

    CONTACT US

    Attn: Mr. Joe Zou
    Email:info86kd@gmail.com | info@kaidi86.com
    Tel: +86 756 8652289
    Fax: +86 756 8652290
    Mob: +86 18198790863 (whatsapp/Wechat Same Number)
    Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

    BETTER TOUCH BETTER BUSINESS

    Contact Sales at KAIDI level gauge manufacturer.

    Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
    Customer service
    detect