6GHz intelligent series radar level meter is suitable for non-contact continuous measurement of level of liquid, slurry, granule and lump material, suitable for temperature and pressure changes; occasions where inert gas and volatilization exist.
It adopts the measurement method of microwave pulse, and can work normally in the industrial frequency band range. Low beam energy, can be installed in a variety of metal, non-metallic containers or pipes, no harm to human body and the environment.
Very short microwave pulses of very low energy are transmitted and received through an antenna system. The radar wave travels at the speed of light. The running time can be converted into a level signal by means of electronic components. A special time-stretching method ensures stable and accurate measurements in a very short time. Even in the case of complex conditions and spurious echoes, the level echoes can be accurately analyzed using microprocessor technology and commissioning software.
The antenna receives the reflected microwave pulses and transmits them to the electronics. The microprocessor processes this signal and identifies the echoes generated by the micropulses on the material surface. The correct identification of the echo signal is done by the pulse software with an accuracy of millimeters.
The distance D from the material surface is proportional to the time travel T of the pulse: D=C×T/2; where C is the speed of light. Since the distance E from the empty tank is known, the level L is: L = E - D.
It is set by entering the empty tank height E (=zero), full tank height F (=full range) and some application parameters, which will automatically adapt the instrument to the measurement environment. Corresponds to 4-20mA output.
This instrument fully meets the requirements of protection class IP66/67. Please make sure
that the cable sealing head is waterproof. As shown
How to ensure that the installation meets the requirements of IP67:
Please make sure that the sealing head is not damaged.
Please ensure that the cable is not damaged.
Please ensure that the cable used meets the requirements of the electrical connection specification.
Before entering the electrical connection, bend the cable downwards to
ensure that water does not flow into the housing, see ①
Please tighten the cable sealing head, see ②
Please plug the unused electrical connections with blind plugs, see ③
Applicable medium: Liquid, especially suitable for strong corrosive liquid
Applications: level measurement with pressure; level measurement of sewage;
level measurement of volatile acid and alkali
Explosion-proof certification: Exia IIC T6 Ga/Exd IIC T6 Gb
Measuring range: 20m
Antenna: Rod antenna (PTFE)
Frequency: 6 GHz
Process temperature: -40 to 130°C (standard type) / -40 to 180°C (high temperature type)
Measurement accuracy: ±10mm
Process pressure: (-0.1 to 1.6) MPa
Signal output: (4~20)mA/HART
Field display: four-digit LCD programmable
Power supply: two-wire (DC24V) four-wire (DC24V/AC220V)
Repeatability: ± 1mm
Housing: Aluminum single chamber/aluminum double chamber/plastic/stainless steel single chamber
Process connection: Flanged flange
Datos generales: Material Antena PTFE, PP
Carcasa: Aluminio, plástico, PP antiestático, acero inoxidable 316
Junta entre la carcasa y la caja: Goma de silicona
Mirilla de la carcasa: Policarbonato
Terminal de tierra: acero inoxidable
Conexión de proceso: KD-801 G1½″A rosca o 1½″NPT rosca / bridaKD-802 Brida de PTFEKD-803 Brida de acero inoxidable
KD-804 Brida de acero inoxidableKD-805 Brida de acero inoxidableKD-806 Brida de acero inoxidable
Tensión de alimentación: 2 hilos tipo estándar (16-26)V DCSeguridad intrínseca (21,6 a 26,4)V CCConsumo máx. 22,5 mA
Ondulación admisible- <100Hz Uss < lV- (100 a 100K)Hz Uss < l0mV
A prueba de explosiones (22. 8 a 26. 4) V CC 2 hilos (198 a 242) V AC 4 hilos / 110V AC 4 hilosConsumo máx. 1VA, 1W
Parámetros del cable: Entrada de cable/enchufe 1 entrada de cable M20xl.5 (diámetro del cable de 5 a 9 mm)1 tapón ciego M20xl.5
Regleta de bornes de resorte: para sección de conductor de 2,5 mm².
Parámetros de salida: Señal de salida (4 a 20)mA/HART
Resolución: 1,6 µA
Señal de fallo: Salida de corriente constante; 20,5mA; 22mA; 3,9mA
Resistencia de carga a dos hilos: ver diagrama inferior
Resistencia de carga a cuatro hilos: 500Ω máx.
Tiempo de integración: (0 a 36) s, ajustable
Parámetros característicos: Área ciega Extremo de la antenaKD-801 20m (líquido)KD-802 20m (líquido)
KD-803 35mKD-804 35mKD-805 20mKD-806 15m
Intervalo de medición: aprox. 1s (dependiendo del ajuste de los parámetros)
Tiempo de ajuste: aprox. 1s (dependiendo de la configuración de los parámetros)
Resolución: 1mm
Precisión: 10mm o <0,1% (ver diagrama de precisión más abajo)
Temperatura de almacenamiento y transporte: (-40 a 80) °C
Temperatura de proceso: (temperatura de la sección de la antena)KD-801 -40 a 130 °CKD-802 -40 a 130 °C (tipo estándar) / -40 a 180 °C (tipo alta temperatura)
KD-803 -40~130℃ (tipo estándar) / -40~180℃ (tipo alta temperatura)KD-804 -40~130℃ (tipo estándar) / -40~180℃ (tipo alta temperatura)
KD-805 -40~130℃ (tipo estándar) / -40~180℃ (tipo alta temperatura)KD-806 (-40~400)°C
Humedad relativa: <95%.
Presión en el interior del depósito: máx. 4 MPa
Resistencia a las vibraciones : Vibración mecánica l0m/s² , (10~150)Hz
La posición recomendada (2) es desde la pared del depósito hasta la pared exterior del tubo de instalación para cumplir los siguientes requisitos: la distancia óptima desde la pared del depósito es 1/4 o 1/6 del diámetro del depósito y la distancia mínima de instalación desde la pared del depósito es 1/10 del rango de medición. por ejemplo, para un depósito de 10 m de nivel, la distancia mínima de instalación desde la pared del depósito debe ser de 1 m.
● No se puede instalar por encima de la entrada (4).
● No puede instalarse en el centro (3), si se instala en el centro, se generarán múltiples ecos espurios y los ecos de interferencia provocarán la pérdida de la señal verdadera.
Si no se mantiene la distancia entre el instrumento y la pared del tanque, el medio en la pared del tanque se adherirá y causará ecos falsos, que deben guardarse al poner en servicio el instrumento.