Home  >  PRODUCT  >  Level Instrument  >  Radar Level Meter  > 

Kaidi KD-FMF11 FM radar level meter 120G FM radar type level measuring instrument 「anti-corrosion type」

这里可以自定义设置
Kaidi KD-FMF11 FM radar level meter 120G FM radar type level measuring instrument 「anti-corrosion type」
B站不支持收货地址
B站不支持库存规格
Application:
Liquid
Measuring Range:
0.05m~30m
Protection Grade:
IP67
Accuracy:
±2mm
Frequency:
123GHz
Process Pressure:
(-0.1~0.3)Mpa
Process Temperature:
-40℃~80℃
Process Connection:
G1½ A/1½NPT thread/flange ≥ DN50
Explosion proof certification:
ExiaⅡCT6Ga/ExdⅡCT6Gb
Outer Covering:
Aluminum/plastic/stainless steel
Power supply
Two-wire(DC24V)/Four-wire(DC12V~24V)/Four-wire(AC220V)
Signal output
2-wire 4... .20mA / HART protocol / 4-wire 4... .20mA /RS485 Modbus
MOQ
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
参数暂无数据
多属性暂无数据
B站不支持优惠卷

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障

  PRODUCT OVERVIEW

  Kaidi KD-FMF11 FM radar level meter is a 120G FM radar type level measuring instrument with a measuring distance of up to 30 meters. The antenna is further optimized for processing and the new fast microprocessor allows for higher speed signal analysis and processing, making the instrument available for measurement of high temperature and high pressure and other environmental liquids.

product-Kaidi Sensors-img


  

THE PRODUCT PRINCIPLE

  The general principle of frequency modulated continuous wave radar level meter is that the radar emits electromagnetic waves at the top of the tank, and the electromagnetic waves are received by the radar after hitting the medium and reflected. Because the speed of light C and FM slope K are known, so the frequency difference δ f is estimated, and the distance R of the material surface at the radar installation position can be obtained, and then the height of the material level is obtained by subtracting the spatial distance from the radar to the material surface (referred to as the empty height) from the known total height of the tank.

product-Kaidi Sensors-Kaidi KD-FMF11 FM radar level meter 120G FM radar type level measuring instrum

PROTECTION GRADE

  

This instrument fully meets the requirements of protection class IP66/67. Please make sure that the cable sealing head is waterproof. As shown

How to ensure that the installation meets the requirements of IP67.

Please make sure that the sealing head is not damaged.

Please make sure that the cable is not damaged.

Please ensure that the cable used meets the requirements of the electrical connection specification.

Before entering the electrical connection, bend the cable downwards to ensure that water does not flow into the housing, see ①

Please tighten the cable sealing head, see ②

Please plug the unused electrical connections with blind plugs, see ③

product-Kaidi Sensors-img

  PRODUCT SPECIFICATION

product-Kaidi Sensors-img


Measuring medium: liquid

Measuring range: 0.05m~30m 

Process connection: G1½ A/1½NPT thread/flange ≥ DN50 

Process temperature: -40~80℃

Process pressure: -0.1~0.3MPa

Accuracy: ±2mm 

Protection level: IP67

Frequency range:123GHz

Power supply:Two-wire(DC24V)/Four-wire(DC12V~24V)/Four-wire(AC220V)

Explosion-proof grade: Exia ⅡC T6 Ga / Exd IIC T6 Gb

Housing: Aluminum / Plastic / Stainless steel

Signal output: 2-wire 4.... .20mA / HART protocol / 4-wire 4.... .20mA /RS485 Modbus

APPEARANCE OF SIZE

product-Kaidi Sensors-img

TECHNICAL PARAMETERS

Process connectionFlange
Material304 stainless steel, PP
ShellSeal between housing and housingSilicone Rubber
Shell windowPolycarbonate
Ground terminalStainless steel
Supply voltagefour-wire systemStandard12~24)V DC
Power consumptionmax80mA DC24V/2W
Allow ripple100HzUss<1V

100~100K)HzUss<10mV
Shell(198~242)V ACfour-wire system
100V ACfour-wire system
Cable parametersCable entry/plug1 M20x1.5 cable entry
1 blind plug M20×15
Ground terminalConductor cross section 2.5mm2
Output parametersoutput signal4~20)mA/RS485Modbus
Resolution1mm
Fault signalCurrent output unchanged; 20.5mA; 22mA; 3.9mA
Integration time(0~20)s, adjustable
Blind spot0.1m/0.2m/0.3m
Maximum measurement interval150 meters
Measuring distanceAbout 1 second (depending on parameter settings)
Adjust the timeAbout 1 second (depending on parameter settings)
Adjust time, working storage and transportation temperature-40~80)℃
Process temperatureKD-FMF11-40~80
KD-FMF12-40~110
KD-FMF13-40~110
KD-FMF15-40~200
KD-FMF21-40~110
Relative humidity95%
pressureMax2.5MPa
ShockproofMechanical vibration 10m/s2, (10~150)Hz

INSTRUMENT LINEARITY

product-Kaidi KD-FMF11 FM radar level meter 120G FM radar type level measuring instrument 「anti-corr

INSTALLATION REQUIREMENTS

When installing the instrument, avoid installing it above the inlet, and try to avoid all kinds of objects that affect the signal, such as stirring paddles, etc.

product-Kaidi Sensors-img-1

Under extremely complicated working conditions, the instrument can work normally if there is no obstacle in the area of 500px radius with the radar installation point as the center.product-Kaidi Sensors-Kaidi KD-FMF11 FM radar level meter 120G FM radar type level measuring instrum-1product-Kaidi Sensors-img-1

Under extremely complicated working conditions, the instrument can work normally if there is no obstacle in the area of 500px radius with the radar installation point as the center.


Product Message
社媒暂无评论
Chat Online 编辑模式下无法使用
Leave Your Message inputting...