loading
Kaidi Sensors | Level gauge & level indicator manufacturer
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 1
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 2
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 3
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 4
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 5
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 1
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 2
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 3
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 4
Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 5

Kaidi KD-806 6GHz Intelligent Radar Level Meter 20+ Years Experience

6GHz OEMService First-Class Radar Level Meter China Supplier
5.0
Application:
Charge level measurement of high furnace,Measurement of solids, especially media at high temperatures
Measuring Range::
15m
Accuracy::
±20mm
Frequency:
6 GHz
Process Pressure::
(-0.1~0.3)Mpa
Process Temperature::
-40°C~400°C
Process Connection::
Flange
Explosion proof certification:
Exia IIC T6 GA/Exd IIC T6 GB
Outer Covering::
Single chamber/aluminum Double chamber/plastic/stainless steel Single chamber
Power supply:
Two-wire (DC24V) / four-wire (DC24V / AC220V)
Signal output:
(4~20)mA/HART
MOQ:
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
design customization

    oops...!

    no product data.

    Go to homepage
    KD R806 6GHz Intelligent Radar Level Meter 80X.pdf
    KD R806 6GHz Intelligent Radar Level Meter 80X.pdf

    PRODUCT OVERVIEW

    6GHz intelligent series radar level meter is suitable for non-contact continuous measurement of level of liquid, slurry, granule and lump material, suitable for temperature and pressure changes; occasions where inert gas and volatilization exist.


    It adopts the measurement method of microwave pulse, and can work normally in the industrial frequency band range. Low beam energy, can be installed in a variety of metal, non-metallic containers or pipes, no harm to human body and the environment.


    Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 6

    THE PRODUCT PRINCIPLE

    Very short microwave pulses with very low energy are transmitted and received through the antenna system. The radar wave travels at the speed of light. The running time can be converted into a level signal by means of electronic components. A special time-stretching method ensures stable and accurate measurements in a very short time. Even in the case of complex conditions and spurious echoes, the level echoes can be accurately analyzed using microprocessor technology and commissioning software.

    Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 7

    The antenna receives the reflected microwave pulses and transmits them to the electronics. The microprocessor processes this signal and identifies the echoes generated by the micropulses on the material surface. The correct identification of the echo signal is done by the pulse software with an accuracy of millimeters.


    The distance D from the material surface is proportional to the time travel T of the pulse: D=C×T/2; where C is the speed of light. Since the distance E from the empty tank is known, the level L is: L = E - D.


    It is set by entering the empty tank height E (=zero), full tank height F (=full range) and some application parameters, which will automatically adapt the instrument to the measurement environment. Corresponds to 4-20mA output.


    PROTECTION GRADE

    Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 8This instrument fully meets the requirements of protection class IP66/67.

     Please make sure that the cable sealing head is waterproof. As shown

    How to ensure that the installation meets the requirements of IP67.

    Please make sure that the sealing head is not damaged.

    Please make sure that the cable is not damaged.

    Please ensure that the cable used meets the requirements of the electrical connection specification.

    Before entering the electrical connection, bend the cable downwards to ensure that water 

    does not flow into the housing, see ①

    Please tighten the cable sealing head, see ②

    Please plug the unused electrical connections with blind plugs, see ③


    PRODUCT SPECIFICATION

    Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 9Applicable media: Solids, especially high temperature environment media measurement

    Application: Blast furnace level measurement

    Explosion-proof certification: Exia IIC T6 Ga/Exd IIC T6 Gb

    Measuring range: 15m

    Antenna: Horn antenna

    Frequency: 6 GHz

    Process temperature: (-40 to 400)°C

    Measurement accuracy: ±20mm

    Process pressure: (-0.1~0.3)MPa

    Signal output: (4 to 20)mA/HART

    Field display: four-digit LCD programmable

    Power supply: two-wire (DC24V) four-wire (DC24V/AC220V)

    Repeatability: ± 1mm

    Housing: Single chamber/aluminum Double chamber/plastic/stainless steel Single chamber

    Process connection: Flange


    APPEARANCE OF SIZE

    Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 10

    TECHNICAL PARAMETERS

    General data Material Antenna PTFE, PP

    Housing Aluminum, plastic, antistatic PP, stainless steel 316

    Seal between housing and enclosure Silicone rubber

    Housing sight glass Polycarbonate

    Grounding terminal Stainless steel

    Process connection HBRD801 G1½″A thread or 1½″NPT thread / flange

    KD-802 PTFE flanged flange

    KD-803 Stainless Steel Flange

    KD-804 Stainless Steel Flange

    KD-805 Stainless Steel Flange

    KD-806 Stainless Steel Flange

    Power supply voltage Two-wire system Standard type (16~26)V DC

    Intrinsically safe (21.6~26.4)V DC

    Power consumption max. 22.5mA

    Allowable ripple

    - <100Hz Uss < lV

    - (100~100K)Hz Uss < l0mV

    Flameproof type (22. 8 to 26. 4) V DC Two-wire system

      (198~242) V AC 4-wire / 110V AC 4-wire

    Power consumption max. 1VA, 1W

    Cable parameters Cable inlet/plug 1 M20xl.5 cable inlet (cable diameter 5 to 9 mm)

    1 blind plug M20xl.5

    Spring terminal block for wire cross section 2.5 mm²

    Output parameters Output signal (4 to 20)mA/HART

    Resolution 1.6μA

    Fault signal Current output constant; 20.5mA; 22mA; 3.9mA

    Two-wire load resistance See figure below

    Four-wire load resistance 500Ω max.

    Integration time (0 to 36)s, adjustable

    Characteristic parameters Blind area End of antenna

    KD-801 20m (liquid)

    KD-802 20m (liquid)

    KD-803 35m

    KD-804 35m

    KD-805 20m

    KD-806 15m

    Measurement interval approx. 1s (depending on parameter setting)

    Adjustment time approx. 1s (depending on parameter setting)

    Resolution 1mm

    Accuracy 10mm or <0.1% (see accuracy diagram below)

    Operating storage and transport temperature (-40 to 80) °C

    Process temperature (temperature of antenna section)

    KD-801 -40~130℃

    KD-802 -40~130℃ (standard type) / -40~180℃ (high temperature type)

    KID-803 -40~130℃ (Standard type) / -40~180℃ (High temperature type)

    KD-804 -40~130℃ (standard type) / -40~180℃ (high temperature type)

    KD-805 -40~130℃ (standard type) / -40~180℃ (high temperature type)

    KD-806 (-40~400)℃

    Relative humidity <95%

    Pressure inside the tank Max. 4MPa

    Shock resistance Mechanical vibration l0m/s² , (10~150)Hz


        INSTRUMENT LINEARITY


    Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 11

    Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 12

    INSTALLATION REQUIREMENTS

    Recommended location (2), the tank wall to the outer wall of the installation short pipe should meet the following requirements: the best distance from the tank wall is 1/4 or 1/6 of the tank diameter, the minimum installation distance from the tank wall is 1/10 of the measurement range. for example: 10m level tank, the minimum installation distance from the tank wall should be 1m.

    Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 13

    ● Cannot be installed above the inlet (4)


    ● It cannot be installed in the center (3). If it is installed in the center, multiple false echoes will be generated and the interference echoes will cause the real signal to be lost.


    ● If the distance between the instrument and the tank wall cannot be maintained, the medium on the tank wall will adhere to cause false echoes, and false echoes should be stored during the commissioning of the instrument.

                                                               Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 14      Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 15      Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 16

                                                                      Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 17               Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 18   Kaidi KD-806  6GHz Intelligent Radar Level Meter 20+ Years Experience 19        

    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs.
    Related Products

    CONTACT US

    Attn: Mr. Joe Zou
    Email:info86kd@gmail.com | info@kaidi86.com
    Tel: +86 756 8652289
    Fax: +86 756 8652290
    Mob: +86 18198790863 (whatsapp/Wechat Same Number)
    Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

    BETTER TOUCH BETTER BUSINESS

    Contact Sales at KAIDI level gauge manufacturer.

    Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
    Customer service
    detect