loading
Kaidi Sensors | Level gauge & level indicator manufacturer
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 1
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 2
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 3
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 4
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 5
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 1
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 2
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 3
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 4
kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 5

kaidi KD-902T Radar level meter that generates heat "Anti-corrosion type

5.0
Application:
Corrosive liquids, vapors, volatile liquids
Measuring Range::
20m
Protection Grade::
IP67
Accuracy::
±3mm
Frequency:
26GHz
Process Pressure::
(-0.1~2.0)Mpa
Process Temperature::
-40~130℃( standard type ) / -40~250℃( high temperature type )
Process Connection::
Threads, flanges
Explosion proof certification:
Exia ⅡC T6 Ga / Exd IIC T6 Gb
Outer Covering::
Aluminum Single Chamber / Aluminum Double Chamber / Plastic / Stainless Steel Single Chamber
Power supply:
Two-wire (DC24V) / four-wire (DC24V / AC220V)
Signal output:
(4~20)mA/HART(2-wire/4-wire)RS485/Modbus
MOQ:
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
design customization

    oops...!

    no product data.

    Go to homepage

    PRODUCT OVERVIEW

    KD90X series sensors are 26G high frequency radar type level measuring instruments with measuring distance up to 80 meters. The antenna is further optimized and the new fast microprocessor allows for higher speed signal analysis and processing, making the instrument available for measurement of a variety of highly corrosive liquids.

    kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 6


    THE PRODUCT PRINCIPLE

    The radar level antenna emits narrow microwave pulses, which are transmitted downward by the antenna. Microwave contact with the measured media surface is reflected back again by the antenna system, the signal will be transmitted to the electronic circuit part automatically converted into a level signal (because the microwave propagation speed is very fast, electromagnetic waves to reach the target and return to the receiver by the reflection of the time used in this round trip is almost instantaneous).

    kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 7

                                                                                       A: range setting, B: low level adjustment, C: high level adjustment, D: blind range

    The reference surface for measurement is: the bottom surface of the thread or the sealing surface of the flange.


    Note: When using the radar level meter, make sure that the highest material level cannot enter the measurement blind zone (the area shown in D in the figure).

    PRODUCT FEATURES

    ● Level meter that will heat up, low temperature resistant, self-heating, non-freezing, and anti-crystallization.

    ● Virtually unaffected by corrosion, foam; virtually unaffected by water vapor, temperature and pressure changes in the atmosphere.

    ● Severe dusty environment has little effect on the work of high frequency level meter.

    ● Shorter wavelength, better reflection on inclined solid surfaces.

    ● Smaller beam angle and concentrated energy, which enhances the return capability and helps to avoid interfering objects at the same time.

    ● Smaller measurement blind spot, and good results for small tank measurements.

    ● High signal-to-noise ratio for better performance even under fluctuating conditions.

    ● High frequency, a better choice for measuring solids and low dielectric constant media.

    kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 8

    PRODUCT SPECIFICATION

    Applications: temperature- and pressure-resistant, slightly corrosive liquids

    Measuring range: 20 meters 

    Process connection: thread, flange 

    Process temperature:-40~130℃( standard type ) / -40~250℃( high temperature type )

    Process pressure: -0.1~2.0MPa 

    Accuracy:±3mm 

    Protection grade: IP67 

    Frequency range: 26GHz 

    Power supply: two-wire system (DC24V) / four-wire system (DC24V/AC220V )

    Explosion-proof grade: Exia ⅡC T6 Ga / Exd IIC T6 Gb 

    Housing: Aluminum single cavity / Aluminum double cavity / Plastic / Stainless steel single cavity

    Signal output: 4.... .20mA/HART ( two wire / four wire ) / RS485 Mod bus

    APPEARANCE OF SIZE

    kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 9

    TECHNICAL PARAMETERS

    Process connections: Thread G1½"A / Thread 1½"NPT / Flange

    Antenna profile: Stainless steel / PTFE

    Housing: Seal between housing and housing cover Silicone rubber

    Housing window: Polycarbonate

    Grounding terminal: Stainless steel

    Supply voltage: 2-wire Standard (16 to 26) V DC

    Intrinsically safe (21. 6 to 26. 4) V DC

    Power consumption: max 22. 5mA / 1W

    Allowable ripple

    Explosion-proof type: - <100Hz Uss < lV

    - (100 to 100K) Hz Uss < l0mV

    (22. 8 to 26. 4) V DC Two-wire system

    (198 to 242) V AC four-wire / 110V AC four-wire

    Cable parameters: Cable inlet/plug 1 M20xl.5 cable inlet

    1 blind plug M20xl.5

    Wiring terminals: Wire cross section 2.5 mm²

    Output parameters: Output signal (4 to 2 0) mA

    Communication protocol: HART

    Resolution: 1.6 µA

    Fault signal: Current output constant

    20. 5mA

    22mA;

    3.9mA

    Integration time: (0~36)s, adjustable

    Blind area End of antenna

    Maximum measuring distance: KD-901 10m (liquid type)

    KD-902 30m (liquid type)

    KD-902T 20m (liquid type)

    KD-903 70m (solid type)

    KD-904 80m (solid type)

    KD-905 30m (Solid type)

    KD-906 20m (Liquid type)

    Microwave frequency :26GHz

    Communication interface: HART communication protocol

    Measurement interval: approx. 1 second (depending on parameter settings)

    Adjustment time: approx. 1 second (depending on the parameter setting)

    Display resolution 1mm

    Operating storage and transport temperature : (-40~100) ℃

    Process temperature: (temperature of antenna section) KD-901 (-40 to 130) ℃

    KD-902 (-40~250)℃

    KD-902T (-40~250)℃

    KD-903 (-40~250)℃

    KD-904 (-40~250)℃

    KD-905 (-40~250)℃

    KD-906 (-40~200)℃

    Relative humidity :˂95%

    Pressure : Max. 4MPa

    Shock resistance : Mechanical vibration l0m/s² , (10~150)Hz

    INSTALLATION REQUIREMENTS

    kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 10

                                                                                                   

                              kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 11

    kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 12

                                                                                                         

    kaidi KD-902T Radar level meter that generates heat Anti-corrosion type 13

                                                                                     

    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs.
    Related Products

    CONTACT US

    Attn: Mr. Joe Zou
    Email:info86kd@gmail.com | info@kaidi86.com
    Tel: +86 756 8652289
    Fax: +86 756 8652290
    Mob: +86 18198790863 (whatsapp/Wechat Same Number)
    Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

    BETTER TOUCH BETTER BUSINESS

    Contact Sales at KAIDI level gauge manufacturer.

    Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
    Customer service
    detect