The remote pressure/level transmitter is used to prevent the medium in the pipeline from directly entering the transmitter. The pressure-sensitive diaphragm and the transmitter are connected by a capillary filled with fluid. It is used to measure the level, flow and pressure of liquid, gas or steam, and then convert it into a 4-20mA DC signal output.
After the YH1151/3351 pressure transmitter is equipped with the remote transmission sealing device, it becomes the YH1151/3351GP remote transmission pressure transmitter. It has the various characteristics of the YH1151/3351 pressure transmitter and can be used to perform pressure and liquid level Measurement. It can communicate with the HART handheld communicator, and set up and monitor through it.
YH1151/3351GP remote flange pressure/level transmitter is suitable for the following measurement and control situations:
①The measured medium has a corrosive effect on the sensitive components of the transmitter;
② It is necessary to isolate the high-temperature measured medium from the transmitter;
③There are suspended solids or high-viscosity media in the measured medium;
④The measured medium is easy to solidify or crystallize at the same time when it is led by the pressure pipe;
⑤The measuring head must be strictly purified to replace the measured medium
⑥The measuring head must be kept hygienic and pollution is strictly prohibited. Use object: corrosive or viscous liquid.
The YH1151/3351GP remote pressure/level transmitter has four types of remote transmission devices:
①1191PFW flat remote transmission device;
②1191RTW threaded remote transmission device;
③1191RFW flange-mounted remote transmission device;
④1191EFW inserting barrel type remote transmission device.
YH1151/3351GP | Remote pressure/level transmitter | |
Code | Range KPa | |
3 | 0-1.3~7.5 | |
4 | 0-6.2~37.4 | |
5 | 0-31.1~186.8 | |
6 | 0-117~690 | |
7 | 0-345~2068 | |
8 | 0-117KPa~1MPa | |
9 | 0-0.4~2.5MPa | |
0 | 0-1.6~10MPa | |
Code | Output | |
E | 4-20mADC | |
S | Intelligent | |
Code | Flange material | |
22 | 316SST | |
Code | Additional features | |
S1 | A remote transmission device | |
S2 | Two remote transmission devices | |
Code | Options | |
M1 | 0-100% linear indicator | |
M3 | 3 1/2 digit LCD display meter | |
M4 | Smart meter display | |
B1 | Tube bending bracket | |
B2 | Board-mounted bending bracket | |
B3 | Tube mounted flat bracket | |
d | Flameproof dⅡBT4 | |
i | Intrinsically safe type iaⅡCT6 |
Note:
1. According to user requirements, the use temperature of 200 series silicone oil is -40~+149℃; the temperature of high temperature resistant silicon oil is -20~+315℃.
2. For corrosive media, select the material of the isolation diaphragm.
Flat remote transmission device order specification table
Thread-mounted remote transmission device order specification table
Insert the barrel type remote transmission device order specification table
Please Send Us your Application details
Measuring range , medium, Installation method (flange, thread), Pressure range, Remote transmitter, Level alarm switch
More Model available for all appication, different termperture and pressure!
We are here to help you! If you close the chatbox, you will automatically receive a response from us via email. Please be sure to leave your contact details so that we can better assist
Our technical team will check your specifications and make a best solution for you.