Home  >  PRODUCT  >  Temp & Press Transmitter  >  Pressure transmitter  > 

Kaidi KD YH 2088 Submersible Liquid Level Transmitter anti-impact and anti-lightning design

这里可以自定义设置
Kaidi KD YH 2088 Submersible Liquid Level Transmitter anti-impact and anti-lightning design

Kaidi KD YH 2088 Submersible Liquid Level Transmitter anti-impact and anti-lightning design
  • Kaidi KD YH 2088 Submersible Liquid Level Transmitter anti-impact and anti-lightning design
  • 16323626789301.jpg
  • Stnless-Steel-Integrated-Submersible-Liquid-Level-Transmitter.webp.jpg
  • `13`3`12`2`3.jpg
  • 52345`123123`.jpg
Kaidi KD YH 2088 Submersible Liquid Level Transmitter anti-impact and anti-lightning design
Application:
urbanwatersupplyandsewagetreatment,petroleum,chemicalindustry
Measuring Range:
0~1~200mH2O
Protection Grade:
IP68 (pressure sensor part), IP65 (junction box transmitter part)
Accuracy:
0.25% FS (typical) 0.5% FS (maximum
Process Pressure:
2 times full scale pressure
Process Temperature:
-20~80℃
Outer Covering:
4~20) mA (two/three wire system), (0~10/20) mA, (0~5)V, (1-5)V, (0~10)V
MOQ
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
参数暂无数据
B站不支持优惠卷

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障
PRODUCT INTRODUCTION

The YH2088 submersible liquid level transmitter uses a high-performance diffused silicon pressure sensor as the measuring element. After a high-reliability amplifying circuit and precise temperature compensation, the gauge pressure or absolute pressure of the measured medium is converted into a standard voltage or current. Signal. This product is small in size and easy to use and install. It can measure the height of the liquid level from the end of the transmitter to the liquid surface directly by putting it in the water.


FEATURES

1. Using advanced circuit processing technology, stable performance and high sensitivity;

2. A variety of ranges, up to 200m (water column pressure) can be measured;

3. 316L stainless steel isolation diaphragm is used, which is suitable for a variety of measuring media;

4. Flexible configuration, different configurations can be selected according to needs;

5. Integral type and split type are optional;

6. Reverse polarity and over-voltage protection;

7. Anti-impact and anti-lightning design;

8. Laser resistance adjustment temperature compensation, zero point and range can be adjusted on site;

9. Wide range of corrosion resistance, suitable for multi-pass media;

10. Strong overload and anti-interference ability, stable performance


PRODUCT USAGE

Industrial site liquid level measurement and control, urban water supply and sewage treatment, petroleum, chemical industry, power plants, hydrological monitoring, reservoirs, dams, hydropower construction and other fields of liquid level measurement


SCHEMATIC DIAGRAM OF STRUCTURE SIZE



TECHNICAL PARAMETER

Measurement form and range: 01200mH2O;

Allowed overload: 2 times full scale pressure;

Working temperature: -2080℃, temperature compensation: -1070℃, storage temperature: -4080℃;

Accuracy: 0.25% FS (typical) 0.5% FS (maximum);

Stability error: 0.25% FS (typical), 0.5% FS (maximum);

Temperature drift coefficient: 0.01%FS (typical, the range is not less than 5mH2O) 0.03%FS (typical, the range is less than 5mH2O);

Output signal: (420) mA (two/three wire system), (010/20) mA, (05)V, (1-5)V, (010)V;

Power supply: 1536VDC (rated voltage 24VDC);

Load : current output type(U-15V)/0.02A, current output type5K;

Housing material: alloy aluminum:

Diaphragm: 316L stainless steel:

Cable: dedicated waterproof and breathable cable;

Mechanical protection: IP68 (pressure sensor part), IP65 (junction box transmitter part)


SELECTION TABLE

Product

YH2088 Throw-in liquid level transmitter

structure type


1. One-piece type without junction box 2. Split type with junction box

E

Output signal


1. (05) VDC

2. Two-wire system (420) mA (default)

3. (010) VDC

4. Other indications

A□

Accuracy


10.1%F• S 20.25%F• S 30.5%F• S

C□

Probe type


1. The default is standard type (non-corrosive type)

2. Anti-corrosion type

D□

Display mode (only for split type with junction box type)


1. No display (default)

2. 0100% linear indication

3. LCD digital range display (liquid crystal)

4. LCD digital 0100% display (liquid crystal)

5. LED digital tube 0100% display


该产品后台详情无内容

Please Send Us your Application details

Measuring range , medium, Installation method (flange, thread), Pressure range, Remote transmitter, Level alarm switch

Our technical team will check your specifications and make a best solution for you.

社媒暂无评论

More  Model available for all appication, different termperture and pressure!

Chat Online 编辑模式下无法使用
Leave Your Message inputting...