Since the
flowmeter is a very precise device, especially the inside of the device will have very precise components, you must be careful and operate in accordance with the specifications when installing and using it. In particular, it is necessary to take into account the requirements of external conditions and take sun protection, rain protection and lightning protection measures, as well as avoid electromagnetic interference and so on. Specifically, the flowmeter's requirements for installation conditions include the following aspects. 1. Requirements for the bypass pipe: Because the flow may need to be overhauled during the life, in order not to affect the normal production during the overhaul, it is required to install a shut-off valve or a shut-off valve on the front and back pipes of the flowmeter. It is best to set up a bypass pipe. And it is required that the flow control valve must be installed downstream of the flowmeter, so that the measurement of the flowmeter will not be affected during the on-off control process, and all the shut-off valves should be opened when the meter is used for measurement to avoid flow instability. The phenomenon. 2. Requirements for straight pipe sections: circulating water pipeline flowmeter manufacturer introduced that in this type of pipeline, the flowmeter should be installed in a horizontal direction, and the axis of the flowmeter itself must be parallel to the flow direction during installation. Unanimous. It also requires that the upstream pipeline length of the pipeline where the equipment is installed must be within the specified range, and the installation point must take into account the inner diameter of the upstream and downstream pipelines. 3. Requirements for installation and welding: In some cases, welding work is required when installing the flowmeter. At this time, welding with the flowmeter is not allowed, and this work should be completed before installation. And the manufacturer of measuring gas flowmeter reminds that some debris left during welding must be cleaned up before installation, and when cleaning these housework, it is best to use equal-diameter pipes instead of flowmeters to purge the pipes to ensure The instrument is damaged if it is not used during use. The above are the aspects included in the requirements for the installation conditions of the flowmeter. In addition, you must ensure that you are within your range when selecting the model to prevent over-speed operation, so as to ensure the accuracy of the measurement and the service life of the equipment. . In addition, the explosion-proof flowmeter can't change the connection mode of the packet system at will during installation, so as to avoid self-defeating and make it lose the anti-theft function and cause dangerous hidden dangers.
In today's world, have risen to an unexpected level of customized level indicator. It has gained a lot of popularity and has come up with different kinds of variations in its content.
All of the experts Guangdong Kaidi Energy Technology Co., Ltd. consulted stressed that the best recovery plans are the ones made before you need them, not afterward.
The global market is estimated to reach a value of almost customized level indicator in the next decade. have a robust position in the customized level indicator market because of its proven high potency in customized level indicator.
We began investing in our workforce and negotiated deals with major suppliers and providers to lower the cost of equipment so the technicians could enhance the competitiveness of level gauge right away.
Innovative technology helped us produce a strong, reliable product as level gauge for customers, offer superior quality and dependability to our customers, and scale at a quicker pace.