Home  >  PRODUCT  >  Level Instrument  >  Radar Level Meter  >  120GFM Radar Level Meter  > 

Kaidi KD-FMF11 120GFM Radar Level Meter Grains Silos Level Indicator Radar Level Sensor

这里可以自定义设置
Kaidi KD-FMF11 120GFM Radar Level Meter Grains Silos Level Indicator Radar Level Sensor
B站不支持收货地址
B站不支持库存规格
Application:
Liquid
Measuring Range:
0.05m~30m
Protection Grade:
IP67
Accuracy:
±2mm
Frequency:
123GHz
Process Pressure:
-0.1~0.3MPa
Process Temperature:
-40~80℃
Process Connection:
G1 ½ A / 1 ½ NPT thread / flange ≥ Dn40
Explosion proof certification:
Exia IIC T6 Ga / Exd ia IIC T6 Gb / Ex ia D20 T85℃
Outer Covering:
Aluminum / Plastic / Stainless steel
Cable specifications
M20x1.5 1/2NPT
Power supply
Two wire system /dc24v Four wire system /dc12~24v Four wire system /ac220v
Signal output
Two wire system 4 20ma/hart protocol Four wire system 4 20mA/ RS485Modbus
MOQ
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
参数暂无数据
多属性暂无数据
B站不支持优惠卷

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障

1.Product Overview

The KD-FMF series sensor is a 120G frequency modulation radar type level measuring instrument with a measuring distance of up to 30 meters. The antenna is further optimized, and the new and fast microprocessor can perform higher-speed signal analysis and processing, so that the meter can be used for measuring high temperature and high pressure and other environmental liquids.

2.The Product Principle

The general principle of the FM continuous wave radar level gauge is that the radar emits electromagnetic waves on the top of the tank, and the electromagnetic waves are received by the radar after being reflected by the medium. The frequency difference δ f between the received signal and the transmitted signal is proportional to the distance R from the surface of the medium. : R= C (speed) *δ f (frequency difference) /2/K (frequency modulation slope). Because the speed of light C and the frequency modulation slope K are known, the frequency difference δ f can be estimated to obtain the distance R of the material surface at the radar installation position, and then through the known total height of the tank, subtract the spatial distance from the radar to the material surface ( Referred to as the air height), the height of the material level is obtained.

3.Protection Grade

This meter fully meets the requirements of protection class IP66/67, please ensure the waterproofness of the cable sealing head. As shown:

How to ensure that the installation meets the requirements of IP67:


Make sure that the sealing head is not damaged.

Make sure that the cable is not damaged.

Make sure that the cables used meet the requirements of the electrical connection specifications.

Before entering the electrical interface, bend the cable downward to ensure that water does not flow into the housing, see ①

Please tighten the cable sealing head, see ②

Please block the unused electrical interfaces with blind plugs, see ③


4.Product Specification

Measuring medium: liquid

Measuring range: 0.05m~75m

Process connection: G1½ A/1½NPT thread/flange ≥DN50

Process temperature: -40~80℃

Process pressure: -0.1~0.3MPa

Accuracy: ±2mm

Protection level: IP67

Frequency range: 120GHz

Power supply:

two-wire system (DC24V)/four-wire system (DC12V~24V)/four-wire system (AC220V)

Explosion-proof grade: Exia ⅡC T6 Ga / Exd IIC T6 Gb

Housing: Aluminum/Plastic/Stainless Steel

Signal output: two-wire system 4...20mA/HART protocol/four-wire system 4...20mA /RS485 Modbus



5.Appearance of Size

6.Technical Parameters

Process connection

Flange

Material

304 stainless steel, PP

Shell

Seal between housing and housing

Silicone Rubber

Shell window

Polycarbonate

Ground terminal

Stainless steel

Supply voltage

four-wire system

Standard

12~24)V DC

Power consumption

max80mA DC24V/2W

Allow ripple

100Hz

Uss<1V

100~100K)Hz

Uss<10mV

Shell

(198~242)V AC

four-wire system

100V AC

four-wire system

Cable parameters

Cable entry/plug

1 M20x1.5 cable entry

1 blind plug M20×15

Ground terminal

Conductor cross section 2.5mm2

Output parameters

output signal

4~20)mA/RS485Modbus

Resolution

1mm

Fault signal

Current output unchanged; 20.5mA; 22mA; 3.9mA

Integration time

(0~20)s, adjustable

Blind spot

0.1m/0.2m/0.3m

Maximum measurement interval

150 meters

Measuring distance

About 1 second (depending on parameter settings)

Adjust the time

About 1 second (depending on parameter settings)

Adjust time, working storage and transportation temperature

-40~80)℃

Process temperature

KD-FMF11

-40~80℃



KD-FMF12

-40~110℃



KD-FMF13

-40~110℃



KD-FMF15

-40~200℃



KD-FMF21

-40~110℃



Relative humidity

95%

pressure

Max2.5MPa

Shockproof

Mechanical vibration 10m/s2, (10~150)Hz



7.Instrument Linearity

8.Installation Requirements

When installing the instrument, avoid installing it above the inlet, and try to avoid various objects that affect the signal, such as stirring paddles, etc.

● Under extremely complex working conditions, the instrument can work normally without any obstacle in the area of 20cm radius centered on the radar installation point.


There can not be installed above the inlet, there can not be obstacles below the instrument

Under extremely complex working conditions, the instrument can work normally without any obstacle in a 20cm radius area centered on the radar installation point.

Product Message
社媒暂无评论
Chat Online 编辑模式下无法使用
Leave Your Message inputting...