Home  >  PRODUCT  >  Level Instrument  >  Magnetic Level Gauge  > 

kaidi KD UZC high temperature and high pressure magnetic level gauge

这里可以自定义设置
kaidi KD UZC high temperature and high pressure magnetic level gauge

kaidi KD UZC high temperature and high pressure magnetic level gauge
  • kaidi KD UZC high temperature and high pressure magnetic level gauge
  • 412·423·4.jpg
  • 412412·4.jpg
  • 41·42·314.jpg
  • %E5%9B%BE%E7%89%873W (2)_副本.png
kaidi KD UZC high temperature and high pressure magnetic level gauge
B站不支持收货地址
B站不支持库存规格
Measuring Range:
300- 15000mm
Accuracy:
±5mm
Process Pressure:
≤42MPa
Process Temperature:
≤450℃
MOQ
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
参数暂无数据
多属性暂无数据
B站不支持优惠卷

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障

1.Principle

UZC type high temperature and high pressure magnetic level gauge is a series of level gauges specially designed by our company for high temperature and high pressure measurement environment. This series of products has the following advantages:

1. The wall thickness simulation design software independently developed according to the pressure vessel design standard can scientifically design the wall thickness of the pressure chamber of the product and the specifications and dimensions of the floating ball according to the pressure and temperature range of the customer's working conditions, effectively improving The pressure-bearing performance and safety performance of this series of products.

2. The pressure-bearing chamber and the floating ball adopt the single-sided welding and double-sided forming process, which effectively guarantees the quality of the welding seam.

3. For different pressure levels, the flange connection sealing surface of this product adopts high pressure design. When the connecting flange sealing surface adopts the RJ ring connection surface, the maximum design pressure can reach 42MPa.

4. Flaw detection and inspection: This series of products will perform a series of flaw detection and inspection on the parts and chambers after welding according to different pressure levels to ensure the quality of the weld and zero defects of the material to the greatest extent.

5. The display panel adopts high temperature isolation technology for high temperature environment, which can effectively isolate the display panel from the high temperature chamber at high temperature, which improves the temperature resistance performance and service life of this product, and the maximum temperature resistance can reach 450 ℃.

6. Water pressure test: After the production is completed, this product will be subjected to a rigorous high-pressure water pressure simulation experiment. The high-pressure water pressure holding test is 1.25-1.5 times of the customer's site design pressure, which is higher than the customer's site use pressure. The water pressure test simulates the customer's on-site use pressure, guarantees the safety performance and sealing performance of this series of products to the greatest extent, and provides the safest and most reliable products for customers' safe production measurement.

product-Kaidi Sensors-img


2.Technical Parameter

product-Kaidi Sensors-img



3.Selection table


Model

illustrate

UZ

Kaidi Magnetic Level Gauge

Type of installation

C

Side loading

D

Top loading

Panel type

A1

-40-80℃ normal temperature

Z1

-190~-20℃ Vacuum

A2

80-180℃ medium temperature

Z2

-20-180℃ Vacuum

A3

180-350℃ high temperature

Z3

Vacuum at 180-350℃

A4

350-450℃ ultra high temperature

E

-40℃-450℃ magnetic sensitivity

Pressure Rating (MPa)

1.0

PN1.0

2.0

CL150LB

1.6

PN1.6

5.0

CL300LB

2.5

PN2.5

11.0

CL600LB

4

PN4.0

15.0

CL900LB

6.3

PN6.3

26.0

CL1500LB

10

PN10.0

42.0

CL2500LB

16

PN16.0



Range-Density

Range mm-density g/cm³

Flange Material

P

304

PF

304 lined with fluorine

PL

316L

C

Carbon steel

PP

PP

Ti

titanium

Flange Diameter

15

Side mounted DN15

50

Top loading DN50

20

Side mounted DN20

65

Top loading DN65

25

Side mounted DN25

80

Top loading DN80

32

Side mounted DN32

100

Top loading DN100

40

Side mounted DN40

125

Top loading DN125

50

Side mounted DN50

150

Top loading DN150

65

Side mounted DN65

200

Top loading DN200

80

Side mounted DN80

250

Top loading DN250

    Flange sealing           surface

Omit

Raised face

FM

Concave

F

Convex

FF

Full plane

Tube material

P

304

P1

321

PL

316L

P4

304L

PF

304 lined with fluorine

Ti

titanium

PP

PP



Insulation/anti-frost

Omit

No

C

Type C insulation pipe (recommended)

T1

Set vacuum insulation

T2

Jacket insulation

D1

40-90 constant temperature electric heating

D2

120°C temperature control adjustable electric heating

S1

Anti-frost below -40°C

S2

-40~-20℃ anti-frost

Accessories

Y

Remote transmission level gauge

K

Alarm switch




4.Product structure display 

product-kaidi KD UZC high temperature and high pressure magnetic level gauge-Kaidi Sensors-img




5.Dimensions

product-Kaidi Sensors-img





Please Send Us your Application details

Measuring range , medium, Installation method (flange, thread), Pressure range, Remote transmitter, Level alarm switch

Our technical team will check your specifications and make a best solution for you.

社媒暂无评论

More  Model available for all appication, different termperture and pressure!

Chat Online 编辑模式下无法使用
Leave Your Message inputting...