loading
Kaidi Sensors | Level gauge & level indicator manufacturer
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 1
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 2
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 3
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 4
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 5
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 1
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 2
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 3
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 4
Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 5

Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter

5.0
Application:
Water
Measuring Range::
0~30 meters
Protection Grade::
IP68
Accuracy::
±5mm
Frequency:
26GHz
Process Pressure::
-0.1~0.3MPa
Process Temperature::
-40~80℃
Process Connection::
Gantry / locking flange from DN 80/ 3
Outer Covering::
PP fully sealed housing
Cable specifications:
M20 x 1.5
Power supply:
Two wire system (DC24V) Four wire system (6~24vdc / ac220v)
Signal output:
4...20ma/hart ( two wire / four wire ) RS485-Modbus
MOQ:
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
design customization

    oops...!

    no product data.

    Go to homepage

    1.  Product  Overview

    Principle


    The radar water level antenna emits extremely narrow microwave pulses that travel at the speed of light, and part of the energy is reflected back when it encounters the surface of the measured medium and is received by the same antenna. The time interval between the transmitted pulse and the received pulse is proportional to the distance from the antenna to the surface of the measuring medium. Due to the extremely high propagation speed of electromagnetic waves, the time interval between the transmitted pulse and the received pulse is very small (nanosecond order) and it is difficult to confirm. The high-frequency radar water level gauge uses a special demodulation technology that can accurately identify the transmitted pulse and the received pulse The distance between the antenna and the surface of the measured medium can be further calculated.

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 6





    A    Range set

    B    Low adjustment

    C    High adjustment

    D    Blind area

    Datum measurement:  Screw thread bottom or the sealing surface of the flange.

    Note: Make sure the radar level meter the highest level cannot enter the measuring blind area (Figure D shown below).


    Application characteristics

    The radar water level gauge uses a 26GHz transmitting frequency and has:

    Ø Small beam angle, concentrated energy, stronger anti-interference ability, greatly improved measurement accuracy

    Ø The antenna is small in size, easy to install, and easy to add dust cover and other antenna protection devices

    Ø Lighter weight, about 1KG, easy to install

    Ø The maximum measurement range can reach 70 meters, which can cover water level measurement such as large reservoirs

    Ø With a variety of output circuit interface and data acquisition system.

    Ø The pulse working mode, radar level meter transmit power is very low, no harm to human body and environment.


    2. Product  Introduction 

    908F

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 7

    Application: sewers, manholes, and waterways

    Measuring Range: 0~30 meters

    Process Connection: Gantry frame / locking flange from DN 80/ 3"

    Temperature: -40℃ ~ 80℃

    Process Pressure: -0.1~0.3MPa

    Precision: ± 5mm

    Frequency : 26GHz

    Protection Grade: IP68

    Power Supply:  DC(6~24VDC/AC220V)  / 4-wire

                             DC 24V / 2-wire

    The Signal output:  Modbus-RS485  

                                   4~20mA / Hart  (2-wire / 4-wire)

    The Scene Display: Optional

    Outer Covering: PP


    3. The  Installation Requirements

     Installation Precautions:

    The 908F is generally used for installation in water wells, mainly connected by a gantry frame or locking flange. Connected with a gantry frame, it can be installed on the side wall and top of the water well; When installed on the top, lifting is also used, as shown in the following figure.


    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 8Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 9


    Precautions during installation:

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 10Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 11Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 12


    4. The Electrical Connection  

    • The power supply voltage:

    (4~20)mA/HART (Two wire system)

    The power supply and output current signal share a two core shielded cable. Please refer to the technical data for the specific power supply voltage range. For intrinsically safe types, a safety barrier must be added between the power supply and the instrument.

    (4~20)mA/HART (Four wire system)The power supply and current signal are separated and each uses a two core shielded cable. Please refer to the technical data for the specific power supply voltage range.
    Modbus - RS485

    Power supply and Modbus signal lines separated respectively using a shielded cable, the power supply voltage range of see technical data.

    • Connection method

    The 24VDC two wire system wiring diagram is as follows:


    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 13

    The 6-24VDC four wire system wiring diagram is as follows:

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 14





     Safety  instructions:

    Ø Please observe the local electrical code requirements!

    Ø Please comply with local requirements for personnel health and safety regulations.

        All electrical components of instrument operation must be completed by the formal training of professionals.

    Ø Please check the instrument nameplate to provide product specifications meet your requirements. Please make sure that the power supply voltage and instrument nameplate on the requirements.


     Protection  grade:

    This instrument fully meets the requirements of protection level IP68, please ensure the waterproofing of the cable sealing head. As shown below:


    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 15

    How to ensure that the installation meets the requirements of IP68:

    Please ensure that the sealing head is not damaged.

    Please ensure that the cable is not damaged.

    Please ensure that the cables used comply with the electrical connection specifications.

    Before entering the electrical interface, bend the cable downwards to ensure that water does not flow into the casing.

    Please tighten the cable sealing head.

    Please plug unused electrical interfaces tightly with blind plugs.




    5. Instrument Commissioning

    There are three kinds of debugging method:

    ① Split display/buttons (if equipped with split display, debugging needs to be carried out on the split, and the connection method is shown in the attached connection diagram)

    ② Upper computer software debugging

    ③ HART handheld programmer (4-20mA output)

     

    Display / Button: 

    Debug the meter through the 4 buttons on the display screen. The debugging menu has four languages to choose from. The measured value can be read very clearly through the glass window.

    Display / Button    

                                                                                                        ① Liquid crystal display(LCD)   ② Adjust by button

           

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 16

     PC software debugging:

    Connected to PC by HART

    RS232 interface/USB interface      ②  Radar level meter    ③ HART converter    ④  250Ω resistor

         

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 17

     Connected to PC by RS485

    RS232 interface/USB interface     Radar level meter     ③RS485 converter

        

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 18

    Programming of a HART handheld programmer

    ① HART handheld programmer   ② Radar water level gauge   250 Ω resistor

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 19

    6. Structure Size   (Unit: mm) 

    Product  size:

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 20

    Gantry frame size:

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 21

    7. Technical Parameters

    General data

    The outer shell material 

    PP fully sealed

    Process connectiongantry frame/  locking flange starting from DN 80/3 "


    The power supply

    Two wire system

    DC 24V /  4~20mA   / Power dissipation  0.75W

    Four wire system

    (6~24) V DC / Modbus-RS485 / Power dissipation   90mW

    Allowable ripple

    - <100Hz                                   Uss

    - (100~100K) Hz                      Uss


    Output parameters

    The output signal

    (4 ~ 20) mA / Modbus-RS485

    Communication protocol

    Modbus / HART

    Resolution 

    1.6μA

    Fault signal

    Constant current output; 20. 5mA;22mA;3.9mA

    The integral time 

    (0 ~ 36) s, adjustable


    Characteristic Parameters
    Blind area

    the ends of the antenna

    Maximum distance measuremen

    30 meters

    Microwave frequency

    26GHz

    The measurement interval

    about 1 second (depending on the parameter settings)

    Adjust the time

    about 1 second (depending on the parameter settings)

    Display resolution

    1mm

    Working storage and transportation temperature

     (-40~80) 

    Process temperature (the temperature of the antenna part)

     (-20~100)℃

    Relative humidity ˂ 95%

    Pressure

    Normal atmospheric pressure

    Seismic

    Vibration frequency (10~150) Hz,

    maximum vibration acceleration l0m/s²


    8.   Meter  Linearity

    908F

    The launch angle depends on the antenna size

    -¢76mm                          12°

    Precision                          See chart

    Kaidi KD-908F Rivers, lakes, shoals Cost-Effective High Frequency Radar Level Meter High Quality Silo Radar Level Meter 22

    9. Product  Model  Selection

    908F

    License

    P    standard (non-explosion-proof)

    Process connection / materials

    A gantry frame

    B locking flange from DN 80/3 "

    Y   Special custom

    Seal / process temperature

    V   Viton/(-40~80) ℃

    The electronic unit

    V      Modbus-RS485 / ( 6~24V )DC  4-wire system

    4~20mA / 24V DC / HART  2-wire system

    Shell / protection class

    G   Plastic  Single chamber /IP68

    Cable line

    H aviation connector, can be equipped with leads

    I Lead length 5 meters

    J lead length 10 meters

    K Special Customization

    The scene shows / programming

    A      With

    X     Without



    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs.
    Related Products

    CONTACT US

    Attn: Mr. Joe Zou
    Email:info86kd@gmail.com | info@kaidi86.com
    Tel: +86 756 8652289
    Fax: +86 756 8652290
    Mob: +86 18198790863 (whatsapp/Wechat Same Number)
    Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

    BETTER TOUCH BETTER BUSINESS

    Contact Sales at KAIDI level gauge manufacturer.

    Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
    Customer service
    detect