loading
Kaidi Sensors | Level gauge & level indicator manufacturer
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 1
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 2
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 3
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 4
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 5
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 1
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 2
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 3
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 4
Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 5

Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement

5.0
Application:
Various corrosive liquids
Measuring Range::
0~10meters
Protection Grade::
IP67
Accuracy::
±5mm
Frequency:
26GHz
Process Pressure::
-0.1~0.3MPa
Process Temperature::
-40~130℃
Process Connection::
Thread, Flange
Explosion proof certification:
Exia IIC T6 Ga / Exd ia IIC T6 Gb
Outer Covering::
Aluminum single chamber / aluminum double chamber / plastic single chamber / stainless steel single chamber
Power supply:
Two-wire system(DC24V) Four-wire system(DC24V / AC220V)
MOQ:
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
design customization

    oops...!

    no product data.

    Go to homepage

    1.  Product  Overview

    High Frequency Radar Level Meter 901 adopted 26G high frequency radar sensor, the maximum measurement range can reach up to 30 meters. Antenna is optimized further processing, the new fast microprocessors have higher speed and efficiency can be done signal analysis, the instrumentation can be used for reactor, solid silo and very complex measurement environment.

     

    Principle

    Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous).

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 6


          A    Range set

          B    Low adjustment

          C    High

          D    Blind area 




    Datum measurement:  Screw thread bottom or the sealing surface of the flange.

    Note: Make sure the radar level meter the highest level cannot enter the measuring blind area (Figure D shown below).


    •  The characteristics of 26G radar level meter:

    Ø Small antenna size, easy to install; Non-contact radar, no wear, no pollution.

    Ø Shorter wavelength, and there is better reflection on the solid surface.

    Ø The measurement blind zone is smaller, and good results can be obtained for the measurement of small tanks.

    Ø Hardly affected by corrosion and slight foam.

    Ø Hardly affected by water vapor, temperature and pressure changes.

    Ø Severe dust environment will not affect electromagnetic wave work.

    Ø High signal-to-noise ratio, better performance can be obtained even with fluctuations.

    Ø The wave speed gathering effect is very good, with various types of antennas, it can meet 90% of the working conditions.


    2. Product  Introduction 

    901

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 7

    Application: All kinds of corrosive liquid

    Measuring Range:0~10 meters

    Process Connection: Thread, Flange

    Process  Temperature: -40℃~130℃

    Process Pressure: -0.1~0.3MPa

    Accuracy: ± 5mm     

    Protection Grade: IP67  

    Frequency Range: 26GHz

    Supply:2-wire(DC24V)/ 4-wire(DC24V /AC220V)

    Signal Output:4~20mA /HART (2-wire / 4-wire)

    Modbus-RS485

    Outer Covering:Aluminum / Plastic / Stainless steel

    Explosion-proof Grade:ExiaⅡC T6 Ga/ Exd ⅡC T6 Gb


    3. The  Installation Requirements

     Installation notes:

    There should be no obstacles between the bottom of the antenna and the surface of the measured medium, and the installation in the tank should be avoided as much as possible, such as: human ladders, limit switches, heating equipment, brackets, etc. Also note that the microwave beam must not intersect the material flow.

    When installing, pay attention to the maximum liquid level not to enter the blind area of the measurement; the instrument must be kept a certain distance from the tank wall; the installation of the instrument should make the antenna emission direction perpendicular to the surface of the measured medium as much as possible.

    Instruments installed in explosion-proof areas must comply with the national installation regulations for explosion-proof hazardous areas. Explosion-proof instruments can be installed in places with explosion-proof requirements, and the instruments must be connected to the ground. The shell of the explosion-proof instrument is made of cast aluminum.


    Installation location:

    Radar level meter can be mounted using a threaded connection and flange connection, typically used for the measurement of corrosive liquids in smaller tanks.

    The instrument is installed at 1/4 or 1/6 of the diameter and the PTFE rod is to be inserted into the measuring tank.

              Note: The minimum distance from the tank wall should be 300mm.

                                                                                                                                                                        ① datum    ②The container center or axis of symmetry

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 8

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 9

     


    • For conical tanks, the top is flat, and the meter needs to be installed in the middle of the tank top. It can be guaranteed to measure to the bottom of the cone.


      Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 10





    • Typical installation errors

    Ø Conical tank

    The instrument cannot be installed above the inlet. 

    Note: Sun-shading and rain-proof measures should be taken during outdoor installation..              

                                                                                                                                        ①Correct  ②Error  rainproof measures

               

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 11

    Ø The meter cannot be installed in the middle of the top of an arched or round tank. In addition to producing indirect echoes, it will also be affected by multiple echoes. Multiple echoes may be larger than the signal threshold of true echoes, because multiple echoes can be concentrated through the top, so they cannot be installed in the center.  

                                                                                                                                                                              ①Correct  ②Error

                          

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 12

    Ø When there are obstacles in the tank that affect the measurement, it is necessary to install a reflector to measure normally.

                                                                                                                                                                                   ①Correct  ②Error

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 13


    Container takeover requirements: 

     Make sure that the antenna extends into the tank at least 10mm away.

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 14

    4. The Electrical Connection  

    • The power supply voltage:

    (4~20)mA/HART (Two wire system)

     The power supply and the output current signal sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument.

    (4~20)mA/HART(Four wire system)

    Separate power supply and the current signal, respectively using a two-core shielded cable. The supply voltage range see technical data.

    RS485 / Modbus 

    Power supply and Modbus signal line separated respectively using a two-core shielded cable, the power supply voltage range see technical data.


    • Cable Connection

    General Introduction

    Supply cable can use ordinary two-core cable,  the cable diameter should be (6~12) mm, to ensure that the cable entry seal. If electromagnetic interference exists, recommended to use shielded cable.

     (4~20) mA /HART(Two-wire)

    Supply cable can use ordinary two-core cable.

     (4~20) mA /HART(Four-wire)

    Supply cable should be used with a dedicated ground cable

    Modbus-RS485(Four-wire)

     Shielded cable should be used for the power supply cable.

    Shielding and wiring

    Both ends of the shielded cable should be grounded. Inside the sensor, the shield must be connected to the internal ground terminal. The external ground terminal on the enclosure must be connected to the ground.

    If there is ground current, the shielded cable must be grounded through a ceramic capacitor (for example: 1nF/1500V) far away from the shielding end of the instrument side to block direct and bypass high-frequency interference signals.


    • Connection  mode

    Ø  24V  two wire wiring diagram as follows:

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 15

     Ø  6~24V Modbus-RS485 wiring diagram as follows:

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 16

    • Explosion Proof Connection

    The explosion-proof form of this product is intrinsically safe.The intrinsic safety version sensors (Exia Ⅱc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia Ⅱc T6.

    A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: ExiaⅡc, voltage of power supply: 24V DC±5%, short-circuit current: 135mA, operating current: 4...20mA.

    All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor≤0.1μF/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used.

     


    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 17

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 18

     Safety  instructions:

    Ø Please observe the local electrical code requirements!

    Ø Please comply with local requirements for personnel health and safety regulations.

        All electrical components of instrument operation must be completed by the formal training of professionals.

    Ø Please check the instrument nameplate to provide product specifications meet your requirements. Please make sure that the power supply voltage and instrument nameplate on the requirements.


     Protection  grade:

    This meter fully meets the requirements of protection class IP66/IP67, please ensure the waterproof characteristics of the cable seal.  As shown below:

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 19

         How to install to meet the requirements of IP67:

         Please make sure that the sealing head is not damaged.

         Please make sure that the cable is not damaged.

         Please make sure that the cable for use with electrical connection specification.

         Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the①

         Tighten the cable seal head, see the②

         Please electrical interface will not use blind plug tight, see the③



                                  

                               

              




    5. Instrument Commissioning

    Three kinds of debugging method:

    1) Display / Button (With split display, you need to debug on the split)  

    2) Debug through computer software   

    3) HART Handheld programmer

     

    Display / Button: 

    Debug the meter through the 4 buttons on the display screen. The debugging menu has four languages to choose from. The measured value can be read very clearly through the glass window.

    Display / Button    

    ① Liquid crystal display(LCD)   ② Adjust by button

           

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 20

     PC software debugging:

    Connected to PC by HART

    ① USB interface      ②  Radar level meter    ③ HART converter    ④  250Ω resistor

           

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 21

     


     HART  handheld  programmer:

    ① HART handheld programmer    ②  Radar level meter    ③  250 Ω Resistor

           

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 22


    6. Structure Size   (Unit: mm)

    The outer shell

    Ø Cast aluminum shell

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 23

    Plastic shell

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 24

     

    Product  size:

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 25

     Flange  type:

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 26

    7. Technical Parameters

    General data


    Process Connection 

    Thread G1½″A / Thread 1½″NPT /  Flange

    Antenna Material

     PTFE

    The outer shell material 

    Cast aluminum, stainless steel, plastic 

    The seal between the shell and cover

    Silicone rubber

    Casing window

     Polycarbonate

    The ground terminal 

     Stainless steel


    The power supply voltage

    Two wire system

    24V DC

    Four wire system


    6~24V DC   ( Modbus-RS485 )

    198 ~242 VAC  (Flameproof type /Double chamber)

    110 VAC (Flameproof type /Double chamber)

    Power dissipation

    Max. 22.5mA / 1W

    Allowable ripple

    - <100Hz                                   Uss

    - (100~100K) Hz                      Uss


    The cable parameters


    Cable entrance / plug

    1  M20xl.5 cable entrance

    1  Blind plug (M20×l.5)

    Terminal

     The maximum usable wire is 2.5mm²


    Output parameters


    The output signal

    (4 ~ 20) mA / Modbus-RS485

    Resolution 

    1.6μA

    Fault signal

    Constant current output; 20. 5mA;22mA;3.9mA

    The integral time 

    (0 ~ 36) s, adjustable

    Two-wire load resistance

    See below

    Four-wire load resistance

    Max 500Ω

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 27


    Characteristic Parameters
    Blind area

    the ends of the antenna

    Maximum distance measuremen

    10 meters

    Microwave frequency

    26GHz

    Communication interface 

    HART communication protocol

    Modbus-RS485 communication protoco

    The measurement interval

    about 1 second (depending on the parameter settings)

    Adjust the time

    about 1 second (depending on the parameter settings)

    Display resolution

    1 mm

    Working storage and transportation temperature

     (-4080) 

    Process temperature (the temperature of the antenna part)

     (-40~130)℃ 

    Relative humidit

    ˂ 95%

    Pressure

     Max0.3MPa

    Shock resistance

    Vibration frequency (10~150) Hz,

    maximum vibration acceleration l0m/s²


    8.   Meter  Linearity

    901

    Launch angle         20°

    Accuracy                See below(±5mm) 

    Kaidi KD-901 High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 28

    9. Product  Model  Selection

    901

    License

    P    Standard (Non-explosion-proof)

    I    Intrinsically safe  (Exia C T6 Ga)

    D   Flameproof  (Exd C T6 Gb)

    Antenna Type / Material / Temperature

    F    Sealing horn / PTEE / -40... 13

    Process Connection Material

      Thread G1½″   / PP

    N   Thread 1½″ NPT / PP

    Y    Special custom

    Flange selection (specification / code / material)

    Specification

    PP

    PTFE

    Stainless steel 304

    Stainless steel316L

    DN50

    P1

    F1

    G1

    S1

    DN80

    P2

    F2

    G2

    S2

    DN100

    P3

    F3

    G3

    S3

      

    Container connecting pipe height

       Connecting pipe  100mm          

       Connecting pipe  150mm

    C    Connecting pipe  200mm          

    D    Connecting pipe  250mm      

    The  Electronic Unit

    3   (4~20) mA / 24V DC / HART 2-wire system

    4   (4~20) mA / 220V AC / HART 4-wire system

    5    Modbus-RS485 / 6~24V/ 4-wire system

    Outer Covering / Protection  Grade

       Aluminum / Single chamber / IP67

    H    Aluminum / Double chamber / IP67

    G   Plastic / Single chamber / IP65

    K   Stainless steel / Single chamber / IP67

    Cable Line

    M    M 20×1.5

    N   ½″ NPT

    Display/The Programmer

    A   With

    X   Without



    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs.
    Related Products

    CONTACT US

    Attn: Mr. Joe Zou
    Email:info86kd@gmail.com | info@kaidi86.com
    Tel: +86 756 8652289
    Fax: +86 756 8652290
    Mob: +86 18198790863 (whatsapp/Wechat Same Number)
    Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

    BETTER TOUCH BETTER BUSINESS

    Contact Sales at KAIDI level gauge manufacturer.

    Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
    Customer service
    detect