Kaidi KD-905 High Frequency Radar Sensor With Display High Temperature Protection Grade For Liquids

这里可以自定义设置
Kaidi KD-905 High Frequency Radar Sensor With Display High Temperature Protection Grade For Liquids
B站不支持收货地址
B站不支持库存规格
Application:
Solid particles, powder
Measuring Range:
Liquid 0 ~ 30m / solid block 0 ~ 20m / solid powder 0 ~ 15m
Protection Grade:
IP67
Accuracy:
±15mm
Frequency:
26GHz
Process Pressure:
-0.1 ~ 4.0 Mpa ( flat flange ) / -0.1 ~ 0.3 MPa ( Universal flange)
Process Temperature:
-40 ~ 130℃ ( standard type ) / -40 ~ 230℃ ( high temperature type )
Process Connection:
Thread, Universal Flange, Flat Flange
Explosion proof certification:
Exia IIC T6 Ga / Exd ia IIC T6 Gb
Outer Covering:
Aluminum single chamber / aluminum double chamber / plastic single chamber / stainless steel single chamber
Power supply
Two-wire system (DC24V) / Four-wire system (DC24V / AC220V)
Signal output
4~20ma (two wire / four wire) Mod bus-RS485
MOQ
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
参数暂无数据
多属性暂无数据
B站不支持优惠卷

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障

1.  Product  Overview

High Frequency Radar Level Meter 905 adopted 26G high frequency radar sensor, the maximum measurement range can reach up to 30 meters. Antenna is optimized further processing, the new fast microprocessors have higher speed and efficiency can be done signal analysis, the instrumentation can be used for reactor, solid silo and very complex measurement environment.

 

Principle

Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous).


      A    Range set

      B    Low adjustment

      C    High adjustment

      D    Blind area 




Datum measurement:  Screw thread bottom or the sealing surface of the flange.

Note: Make sure the radar level meter the highest level cannot enter the measuring blind area (Figure D shown below).


  •  The characteristics of 26G radar level meter:

Ø Small antenna size, easy to install; Non-contact radar, no wear, no pollution.

Ø Shorter wavelength, and there is better reflection on the solid surface.

Ø The measurement blind zone is smaller, and good results can be obtained for the measurement of small tanks.

Ø Hardly affected by corrosion and slight foam.

Ø Hardly affected by water vapor, temperature and pressure changes.

Ø Severe dust environment will not affect electromagnetic wave work.

Ø High signal-to-noise ratio, better performance can be obtained even with fluctuations.

Ø The wave speed gathering effect is very good, with various types of antennas, it can meet 90% of the working conditions.




2. Product  Introduction 

905


Application:Solid particles, Powder

Measuring Range:Liquid 0~30m 

                                 /solid block 0~20m/ solid powder 0~15m

Process Connection:Thread,  Flange

Medium Temperature:-40℃~130℃(Standard type)

                                     -40℃~230℃(High temperature type)  

Process Pressure:-0.1~4.0MPa (Flat flange)

                                -0.1~0.3MPa (Universal Flange)

Accuracy:± 15mm   

Protection Grade:IP67

Frequency Range:26GHz

Display:Four-digit LCD programmable

Supply:2-wire(DC24V)/ 4-wire(DC24V /AC220V)

Signal Output:4... 20mA/HART(2-wire / 4-wire)

                            Modbus-RS485

Outer Covering:Aluminum / Plastic / Stainless steel

Explosion-proof Grade:ExiaⅡC T6 Ga/ Exd ⅡC T6 Gb


3. The  Installation Requirements

 Installation notes:

There should be no obstacles between the bottom of the antenna and the surface of the measured medium, and the installation in the tank should be avoided as much as possible, such as: human ladders, limit switches, heating equipment, brackets, etc. Also note that the microwave beam must not intersect the material flow.

When installing, pay attention to the maximum liquid level not to enter the blind area of the measurement; the instrument must be kept a certain distance from the tank wall; the installation of the instrument should make the antenna emission direction perpendicular to the surface of the measured medium as much as possible.

Instruments installed in explosion-proof areas must comply with the national installation regulations for explosion-proof hazardous areas. Explosion-proof instruments can be installed in places with explosion-proof requirements, and the instruments must be connected to the ground. The shell of the explosion-proof instrument is made of cast aluminum.


Installation location:

  • The instrument is installed at 1/4 or 1/6 of the diameter of the tank.  

          Note: The minimum distance from the tank wall should be 200mm.

                                                                                  ① datum           ②The container center or axis of symmetry

 

  • For conical tanks, the top is flat, and the meter needs to be installed in the middle of the tank top. It can be guaranteed to measure to the bottom of the cone.


                 

For storage tanks with accumulated material, the antenna should be vertically aligned with the material surface.If the material surface is uneven or the pile angle is large, use a universal flange to adjust the angle of the horn toward the material surface. 

(Due to the inclined solid surface, the echo will be attenuated and even the signal will be lost.)

  • Container takeover requirements: 

    Make sure that the antenna extends into the tank at least 10mm away.

  • Typical installation errors

Ø Conical tank

The instrument cannot be installed above the inlet. 

Note: Sun-shading and rain-proof measures should be taken during outdoor installation..              

                                                                                                                                          ①Correct  ②Error  

        

   


Ø The meter cannot be installed in the middle of the top of an arched or round tank. In addition to producing indirect echoes, it will also be affected by multiple echoes. Multiple echoes may be larger than the signal threshold of true echoes, because multiple echoes can be concentrated through the top, so they cannot be installed in the center.  

                                            ①Correct  ②Error

                      

Ø When there are obstacles in the tank that affect the measurement, it is necessary to install a reflector to measure normally.

                                                                                                                                      ①Correct                                     ②Error

4. The Electrical Connection  

  • The power supply voltage:

(4~20)mA/HART (Two wire system)

The power supply and the output current signal sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument.

(4~20)mA/HART(Four wire system)

Separate power supply and the current signal, respectively using a two-core shielded cable. The supply voltage range see technical data.

Modbus - RS485(Four wire system)

Power supply and Modbus signal line separated respectively using a two-core shielded cable, the power supply voltage range see technical data.


  • Cable Connection

General Introduction

Supply cable can use ordinary two-core cable,  the cable diameter should be (6~12) mm, to ensure that the cable entry seal. If electromagnetic interference exists, recommended to use shielded cable.

 (4~20) mA /HART(Two-wire)

Supply cable can use ordinary two-core cable.

 (4~20) mA /HART(Four-wire)

Supply cable should be used with a dedicated ground cable

Modbus-RS485(Four-wire)

Shielded cable should be used for the power supply cable.

Shielding and wiring

Both ends of the shielded cable should be grounded. Inside the sensor, the shield must be connected to the internal ground terminal. The external ground terminal on the enclosure must be connected to the ground.

If there is ground current, the shielded cable must be grounded through a ceramic capacitor (for example: 1nF/1500V) far away from the shielding end of the instrument side to block direct and bypass high-frequency interference signals.


  • Connection  mode

Ø  24V  two wire wiring diagram as follows:

 Ø  6~24V Modbus-RS485 wiring diagram as follows:

  • Explosion Proof Connection

The explosion-proof form of this product is intrinsically safe.The intrinsic safety version sensors (Exia Ⅱc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia Ⅱc T6.

A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: ExiaⅡc, voltage of power supply: 24V DC±5%, short-circuit current: 135mA, operating current: 4...20mA.

All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor≤0.1μF/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used.

 


 Safety  instructions:

Ø Please observe the local electrical code requirements!

Ø Please comply with local requirements for personnel health and safety regulations.

    All electrical components of instrument operation must be completed by the formal training of professionals.

Ø Please check the instrument nameplate to provide product specifications meet your requirements. Please make sure that the power supply voltage and instrument nameplate on the requirements.


 Protection  grade:

This meter fully meets the requirements of protection class IP66/IP67, please ensure the waterproof characteristics of the cable seal.  As shown below:

     How to install to meet the requirements of IP67:

     Please make sure that the sealing head is not damaged.

     Please make sure that the cable is not damaged.

     Please make sure that the cable for use with electrical connection specification.

     Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the①

     Tighten the cable seal head, see the②

     Please electrical interface will not use blind plug tight, see the③



5. Instrument Commissioning

Three kinds of debugging method:

1) Display / Button (With split display, you need to debug on the split)  

2) Debug through computer software   

3) HART Handheld programmer

 

Display / Button: 

Debug the meter through the 4 buttons on the display screen. The debugging menu has four languages to choose from. The measured value can be read very clearly through the glass window.

Display / Button    

① Liquid crystal display(LCD)   ② Adjust by button

       

 PC software debugging:

Connected to PC by HART

① USB interface      ②  Radar level meter    ③ HART converter    ④  250Ω resistor

     

   


 HART  handheld  programmer:

① HART handheld programmer    ②  Radar level meter    ③  250 Ω Resistor

    

   


6. Structure Size   (Unit: mm)

The outer shell

Ø Cast aluminum shell

Plastic shell

 

Product  size:

Ø Purge size  (when the dust is large and the purge is needed)

904size:

 Flange  type:

7. Technical Parameters

General data

Process Connection 

Thread G1½″A / Thread 1½″NPT / Flange

Antenna Material

Stainless steel

The outer shell material 

Cast aluminum, stainless steel, plastic 

The seal between the shell and cover

Silicone rubber

Casing window

Polycarbonate

The ground terminal 

Stainless steel


The power supply

Two wire system

24V DC

Four wire system


6~24V DC   ( Modbus-RS485 )

198 ~242 VAC  (Flameproof type /Double chamber)

110 VAC (Flameproof type /Double chamber)

Power dissipation

Max. 22.5mA / 1W

Allowable ripple

- <100Hz                                   Uss<lV

- (100~100K) Hz                      Uss<l0mV


The cable parameters

Cable entrance / plug

1  M20xl.5 cable entrance

1  Blind plug (M20×l.5)

Terminal

 The maximum usable wire is 2.5mm²


Output parameters

The output signal

(4 ~ 20) mA / Modbus-RS485

Resolution 

1.6μA

Fault signal

Constant current output; 20. 5mA;22mA;3.9mA

The integral time 

(0 ~ 36) s, adjustable

Two-wire load resistance

See below

Four-wire load resistance

 Max 500Ω


Characteristic Parameters
Blind area

the ends of the antenna

Maximum distance measuremen

30 meters

Microwave frequency

26GHz

Communication interface 

HART communication protocol

Modbus-RS485 communication protoco

The measurement interval

about 1 second (depending on the parameter settings)

Adjust the time

about 1 second (depending on the parameter settings)

Display resolution

1mm

Working storage and transportation temperature

 (-4080) 

Process temperature (the temperature of the antenna part)

 (-40~130)℃ Standard type/ (-40~230)℃  High temperature type

Relative humidit

˂ 95%

Pressure

Max.0.3MPa(Universal flange)

Shock resistance

Vibration frequency (10~150) Hz,

maximum vibration acceleration l0m/s²


8.   Meter  Linearity

905

The launch angle depends on the antenna size

-Φ76mm                          12°

-Φ96mm                           8°

-Φ121mm                         6°

Accuracy                          See below(±15mm)

9. Product  Model  Selection

905

License

P    Standard (Non-explosion-proof)

        I     Intrinsically safe (Exia C T6 Ga)

       G    Flameproof (Exd C T6 Gb)

Process Connection Material

G   Thread G1½″A / Stainless Steel 304

N   Thread 1½″ NPT / Stainless Steel 304

Y    Special Custom

Flange selection (specification / code / material) 

Specification

Stainless steel 304

Stainless steel 316L

Stainless steel 304+Universal joint

Stainless steel 316+Universal joint

DN80

G2

S2

V2

W2

DN100

G3

S3

V3

W3

DN125

G4

S4

V4

W4

DN150

G5

S5

V5

W5

 

Antenna Type / Material

Antenna selection  (specification / code / material) 

Specification

Standards

With purging

With dust cover

Φ76mm Horn antenna

B1

C1

D1

Φ96mm Horn antenna

B2

C2

D2

Φ121mm Horn antenna

B3

C3

D3

Y   Special Custom

                                             Seal Up / Process Temperature

V   Viton / (-40~130

K   Kalrez / (-40~230) 

The  Electronic Unit

3   (4~20) mA / 24V DC / HART two wire system

4   (4~20) mA / 220V AC / HART Four wire system

5   Modbus-RS485  / 6~24V / Four wire system

Shell / Protection  Grade

   Aluminum / Single chamber / IP67

H    Aluminum / Double chamber / IP67

G   Plastic / Single chamber / IP65

K   Stainless steel / Single chamber / IP67

Cable Line

M    M 20×1.5

N    ½″ NPT

Field Display/The Programmer

A   With

X   Without



Product Message