loading
Kaidi Sensors | Level gauge & level indicator manufacturer
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 1
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 2
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 3
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 4
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 5
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 1
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 2
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 3
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 4
Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 5

Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement

5.0
Application:
Corrosive liquid, steam, volatile liquid
Measuring Range::
0~20 meters
Protection Grade::
IP67
Accuracy::
±5mm
Frequency:
26GHz
Process Pressure::
-0.1~0.3MPa(PVDF)/-0.1~1.0MPa(PFA)
Process Temperature::
-40~110℃(standardtype)/-40~230℃(hightemperaturetype)
Process Connection::
Flange
Explosion proof certification:
Exia IIC T6 Ga / Exd ia IIC T6 Gb
Outer Covering::
Aluminum / Plastic / Stainless steel
Power supply:
Two-wire system(DC24V) Four-wire system(DC24V / AC220V)
MOQ:
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
design customization

    oops...!

    no product data.

    Go to homepage

    1.  Product  Principle

    High Frequency Radar Level Meter 902T adopted 26G high frequency radar sensor, the maximum measurement range can reach up to 20 meters. Antenna is optimized further processing, the new fast microprocessors have higher speed and efficiency can be done signal analysis, the instrumentation can be used for reactor, solid silo and very complex measurement environment.

    • Principle

    Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous).

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 6


          A    Range set

          B    Min.  adjustment

          C    Max. adjustment

          D    Blind area 




    Datum measurement:  Screw thread bottom or the sealing surface of the flange.

    Note: Make sure the radar level meter the highest level cannot enter the measuring blind area (Figure D shown below).


     The characteristics of 26G radar level meter:

    • Ø Small antenna size, easy to install; Non-contact radar, no wear, no pollution.

    • Ø Shorter wavelength, and there is better reflection on the solid surface.

    • Ø The measurement blind zone is smaller, and good results can be obtained for the measurement of small tanks.

    • Ø Hardly affected by corrosion and slight foam.

    • Ø Hardly affected by water vapor, temperature and pressure changes.

    • Ø Severe dust environment will not affect electromagnetic wave work.

    • Ø High signal-to-noise ratio, better performance can be obtained even with fluctuations.

    • Ø The wave speed gathering effect is very good, with various types of antennas, it can meet 90% of the working conditions.


    2. Product  Introduction 

    902T

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 7


    Application:Corrosive liquids, vapors,volatile liquid

    Measuring Range:0~20 meters

    Process Connection: Flange

    Process  Temperature: -40℃~110℃(Standard type)

                                            -40℃~230℃(High temperature type)  

    Process Pressure:-0.1~0.3MPa(PVDF)/ -0.1~1.0MPa(PFA)

    Accuracy: ±5mm   

    Protection Grade:IP67   

    Frequency Range: 26GHz  

    Display: Four-digit LCD programmable

    Supply:2-wire(DC24V)/ 4-wire(DC24V /AC220V ) 

    Signal Output:4... 20mA / HART (2-wire / 4-wire )

                             Modbus-RS485

    Outer Covering:Aluminum / Plastic / Stainless steel

    Explosion-proof Grade:Exia ⅡC T6 Ga / Exd ⅡC T6 Gb


    3. The  Installation Requirements

     Installation notes:

    There should be no obstacles between the bottom of the antenna and the surface of the measured medium, and the installation in the tank should be avoided as much as possible, such as: human ladders, limit switches, heating equipment, brackets, etc. Also note that the microwave beam must not intersect the material flow.

     

    When installing, pay attention to the maximum liquid level not to enter the blind area of the measurement; the instrument must be kept a certain distance from the tank wall; the installation of the instrument should make the antenna emission direction perpendicular to the surface of the measured medium as much as possible.

     

    Instruments installed in explosion-proof areas must comply with the national installation regulations for explosion-proof hazardous areas. Explosion-proof instruments can be installed in places with explosion-proof requirements, and the instruments must be connected to the ground. The shell of the explosion-proof instrument is made of cast aluminum.


    Installation location:

    This product used to measure corrosive liquids, vapors, volatile liquids and to prevent condensation during measurement.

    The instrument adopts flange connection and is installed at 1/4 or 1/6 of the diameter of the tank.   

    Note: The minimum distance from the tank wall should be 200mm.

    Note:  ① datum ②The container center or axis of symmetry

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 8


    • For the top of the flat conical tank, meter can be installed in the middle of the tank top to the bottom of the cone to ensure measurement.


    • Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 9


    • Installation takeover height:  

    Antenna extends into the tank at least 20mm distance.

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 10


    Typical installation errors

    Ø Conical tank

    The instrument cannot be installed above the inlet. 

    Note: Sun-shading and rain-proof measures should be taken during outdoor installation..                      

             ①Correct  ②Error  rainproof measures

               

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 11

    Ø The meter cannot be installed in the middle of the top of an arched or round tank. In addition to producing indirect echoes, it will also be affected by multiple echoes. Multiple echoes may be larger than the signal threshold of true echoes, because multiple echoes can be concentrated through the top, so they cannot be installed in the center.

                                                                                                                                            ①Correct                         ②Error

                          

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 12

    Ø When there are obstacles in the tank that affect the measurement, it is necessary to install a reflector to measure normally

                                                                                                                                            ①Correct                              ②Error

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 13

    4. The Electrical Connection  

    • The power supply voltage:

    (4~20)mA/HART (Two wire system)

    The power supply and the output current signal sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument.

    (4~20)mA/HART(Four wire system)

    Separate power supply and the current signal, respectively using a two-core shielded cable. The supply voltage range see technical data

    RS485 / Modbus(Four wire system)

    Power supply and Modbus signal line separated respectively using a two-core shielded cable, the power supply voltage range see technical data.


    • Cable Connection

    General Introduction 

    Supply cable can use ordinary two-core cable,  the cable diameter should be (6~12) mm, to ensure that the cable entry seal. If electromagnetic interference exists, recommended to use shielded cable.

     (4~20) mA/HART(Two-wire)

    Supply cable can use ordinary two-core cable.

     (4~20) mA/HART(Four-wire)

    Supply cable should be used with a dedicated ground cable.

    Modbus-RS485

    Shielded cable should be used for the power supply cable.

    Shielding and wiring

    Both ends of the shielded cable should be grounded. Inside the sensor, the shield must be connected to the internal ground terminal. The external ground terminal on the enclosure must be connected to the ground.

    If there is ground current, the shielded cable must be grounded through a ceramic capacitor (for example: 1nF/1500V) far away from the shielding end of the instrument side to block direct and bypass high-frequency interference signals.

    • Connection  mode

     Ø 24V  2-wire wiring diagram as follows:


    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 14

    Ø 6~24V Modbus-RS485 wiring diagram as follows:

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 15


    Explosion Proof Connection 

    The explosion-proof form of this product is intrinsically safe.The intrinsic safety version sensors (Exia Ⅱc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia Ⅱc T6.

    A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: ExiaⅡc, voltage of power supply: 24V DC±5%, short-circuit current: 135mA, operating current: 4...20mA.

    All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor≤0.1μF/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used.

     

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 16

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 17



    Safety  instructions:

    Ø Please observe the local electrical code requirements!

    Ø Please comply with local requirements for personnel health and safety regulations.

        All electrical components of instrument operation must be completed by the formal training of professionals.

    Ø Please check the instrument nameplate to provide product specifications meet your requirements. Please make sure that the power supply voltage and instrument nameplate on the requirements.


     Protection  grade:

    This instrument meets the protection class IP66/67 requirements, please ensure the waterproof cable sealing head. The following diagram:

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 18

         How to install to meet the requirements of IP67:

         Please make sure that the sealing head is not damaged.

         Please make sure that the cable is not damaged.

         Please make sure that the cable for use with electrical connection specification.

         Bend the cable down to ensure that water does not flow into the housing, see the①

         Tighten the cable seal head, see the②

         Please electrical interface will not use blind plug tight, see the③






    5. Instrument Commissioning

    Three kinds of debugging method:

    1) Display / Button  (With split display, you need to debug on the split)  

    2) Debug through computer software   

    3) HART Handheld programmer 

      

    Display /  Button: 

    Debug the meter through the 4 buttons on the display screen. The debugging menu has four languages to choose from. The measured value can be read very clearly through the glass window.

    Display / Button  

    ① Liquid crystal display(LCD)

    ② Adjust by button

           

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 19

     PC software debugging:

    Connected to PC by HART

    ① USB interface   ②  Radar level meter    ③  HART converter    ④  250 Ω Resistor

            

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 20

     HART  handheld  programmer:

    ① HART handheld programmer    ②  Radar level meter    ③  250 Ω Resistor

           

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 21


    6. Structure Size   (Unit: mm)

    The Outer Covering:

    Cast aluminum shell

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 22

     

    Plastic shell

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 23

    Product  size:


                                                          Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 24

     

    Flange  type:

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 25

    7. Technical Parameters

    General data

    Process connection

    Thread G1½″A / Thread 1½″NPT /  Flange

    Antenna Material

    PVDF / PFA

    The outer shell material

    Cast aluminum, plastic, stainless steel

    The seal between the shell and the shell cover 

    Silicone rubber

    Casing window 

    Polycarbonate

    The ground termina

    Stainless steel

    The power supply voltage

    Four wire system

    6~24V DC ( Modbus-RS485 )  / 198 ~242 VAC(Flameproof type /Double chamber)  / 110 VAC(Flameproof type /Double chamber)

    Two wire system

     DC 24V

    Power dissipatio

    Max. 22.5mA / 1W 

    Allowable ripple


    - <100Hz                                  Uss

    - (100~100K) Hz                     Uss


    The cable parameters


    Cable entrance / plug

    1  M20xl.5 cable entrance

    1  Blind plug (M20×l.5)

    Terminal

    The maximum usable wire is 2.5mm² 


    Output parameters


    The output signal

    (4 ~ 20) mA / Modbus-RS485

    Resolution 

    1.6μA

    Fault signal

    Constant current output; 20. 5mA;22mA;3.9mA

    Two-wire load resistance

     See below

    Four-wire load resistanc

    Max 500Ω

    The integral time 

    (0 ~ 36) s, adjustable

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 26

    Blind area

    the ends of the antenna

    The maximum distance measuremen

    20 meters

    Microwave frequency

    26GHz

    Communication interface

     HART communication protocol

    Modbus-RS485 communication protoco

    The measurement interval

    about 1 second (depending on the parameter settings)

    Adjust the time

    about 1 second (depending on the parameter settings)

    Display resolution

    1 mm

    Working storage and transportation temperature

     (-4080) 

    Process temperature (the temperature of the antenna part)

    Standard type (40~130)℃ / High temperature type (40~230)℃

    Relative humidit

    ˂ 95%

    Pressure

     Max. 1.0MPa

    Seismi

    Vibration frequency (10~150) Hz,

    maximum vibration acceleration l0m/s²


    8.   Meter  Linearity

    902T

    The launch angle depends on the antenna size

    -Φ63mm                         14°

    Accuracy                         See below(±5mm)

    Kaidi KD-902T High Frequency Non Contact Radar Level Meter Liquid Level Sensor Indicator Measurement 27

    9. Product  Model  Selection

    902F

    License

    P    Standard (Non-explosion-proof)

    I     Intrinsically safe (Exia ⅡC T6 Ga)

    G    Flameproof (Exd C T6 Gb)

    Process Connection Material

               

    Flange selection (specification / code / material)

    Specification

    Stainless steel 304+PVDF

    Stainless steel 304+PFA

    Stainless steel 316L+PVDF

    Stainless steel 316L+PFA

    DN80

    G1

    S1

    Q1

    R1

    DN100

    G2

    S2

    Q2

    R2

    DN125

    G3

    S3

    Q3

    R3

    Y    Special Custom

    Antenna Type / Material

    A   Horn antenna plus protective cover   PVDF /200mm(standard)

    B   Horn antenna plus protective cover   PFA /200mm(standard)

    C   Horn antenna plus protective cover   PVDF /284mm(lengthen)

    D   Horn antenna plus protective cover   PFA  /284mm(lengthen)

    Seal Up / Process Temperature

    V   Viton / (-40~130

    K   Kalrez / (-40~230) ℃

    The  Electronic Unit

    3   (4~20) mA / 24V DC / HART 2-wire system

    4   (4~20) mA / 220V AC / HART 4-wire system

    5   Modbus-RS485 / 6~24V/ 4-wire system

    Outer Covering / Protection  Grade

       Aluminum / Single chamber / IP67

    H    Aluminum / Double chamber / IP67

    G   Plastic / Single chamber / IP65

    K   Stainless steel / Single chamber / IP67

    Cable Line

    M    M 20 ×1.5

       ½″ NPT

    Field Display /The Programmer

    A   With

    X   Without



    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs.
    Related Products

    CONTACT US

    Attn: Mr. Joe Zou
    Email:info86kd@gmail.com | info@kaidi86.com
    Tel: +86 756 8652289
    Fax: +86 756 8652290
    Mob: +86 18198790863 (whatsapp/Wechat Same Number)
    Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

    BETTER TOUCH BETTER BUSINESS

    Contact Sales at KAIDI level gauge manufacturer.

    Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
    Customer service
    detect