Kaidi KDSS86F Rotary Paddle Level Switch Standard flange type

MAIN TITLE
这里可以自定义设置
Kaidi KDSS86F Rotary Paddle Level Switch Standard flange type
B站不支持收货地址
B站不支持库存规格
Application:
Petrochemical industry, metallurgy, building materials, chemical industry, food
Process Connection:
DN65PN0.6
Contact capacity
SPDT 250VAC/ 10A
Power supply
110/220VAC/24VDC
Power
3W
Insulation V.
1500V in 1 minute
Specific gravity
>=0.5g/cm3
Torque
0.3~1Nm
MOQ
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
参数暂无数据
多属性暂无数据
B站不支持优惠卷

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障


Power source110/220VAC/24VDC
Power3W
Contact capacitySPDT 250VAC/ 10A
Speed1 rpm
Insulation V.1500V in 1 minute
Specific gravity>=0.5g/cm3
Torque0.3~1Nm



A unit is usually located through a bin wall at the top, middle or low level of a bin. During normal operation (no material present) a synchronous motor rotates the paddle at 1 RPM. When this paddle rotation is impeded by material, surrounding the paddle, motor will stall and cause the Micro switch to change state. (Indicating an alarm or control) 





The torque spring is applied to adjust the output torque of the shaft, which is set at “weak” position at factory, it is adjustable for target measuring material S.G.(special gravity), if the measured material with higher S.G., please try to release it to more stronger spring force position until you found the proper orientation.

The paddle sensitivity will be interacted by weaker, otherwise, the low S.G. material will release torque spring to the weakest position, which will cause the paddle performance to be more sensitive.

Note: the torque force should not be adjusted during test, avoiding the error check signal.

CAUTION

Make sure the supplying voltage is same as the specifications. Wrong voltage will damage the sensor.

WARNING

To avoid personal injury, DO NOT remove the housing cover after supplying the power. If you will touch any solder joints and terminals, you may receive an electric shock.



Please check that the shaft and the paddle is bended or is damaged; Please check the connect between the shaft and the paddle; Do cleaning the shaft and the paddle timely.



When do installing or maintenance, open the device only after the power source is off.

Please side mount the switch by inclined 15°~20° to decrease the material inflowing impact; The wiring entry face downward, avoid the rain permeate into housing body.

Side and top mounting: KDSS86/KDSS86F/KDSS86FT/KDSS11/KDSS86M/KDSS86MT


Top mounting only: KDSS20/KDSS86G/KDSS86GT



1ProblemNo output signal while the paddle rotates normally 
ReasonCheck the material gravity, the paddle size doesn’t fit for the material 
SolutionsReplace with suitable paddle 
2ProblemThe paddle is distortion or the shaft is bended
ReasonThe inflowing impact force of the material is too big 
SolutionsThe paddle and the shaft should be protected
3ProblemThe paddle doesn’t rotate 
Reason1the power source isn’t on 2the motor is S: damaged
Solutions1check the power wiring  2replace the motor



Please check and confirm the following data:

Voltage: 24 VDC, 110/220/250VAC, 50/60Hz.

Side or top mounting

Material specific gravity (S.G.)

Paddle size: suitable to enter into the flange inlet