loading
Kaidi Sensors  >  AI - Page Sitemap  >  Kaidi Sensors digital radar level meter factory for detecting
Kaidi Sensors digital radar level meter factory for detecting

Kaidi Sensors digital radar level meter factory for detecting
  • Kaidi Sensors digital radar level meter factory for detecting
  • Kaidi Sensors digital radar level meter factory for detecting
  • Kaidi Sensors digital radar level meter factory for detecting
  • Kaidi Sensors digital radar level meter factory for detecting
  • Kaidi Sensors digital radar level meter factory for detecting

Kaidi Sensors digital radar level meter factory for detecting

6 GHz Intelligent Radar Level Meter
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:


Application:

6GHz radar level gauge is suitable for liquid, paste, granule and block material level and non-contact measurement, suitable for changes in temperature, pressure big; there is an inert gas and volatile.

The measurement method of microwave pulse, can work normally in the industrial frequency band range. The beam energy is low, can be installed on all kinds of metal, non-metallic container or pipe, no harm to human body and environment.

Suitable   for Medium:Liquid,   especially with pressure and Volatile Liquid
Explosion-proof   Grade:  Exia IIC T6 Ga/ Exd IIC T6 Gb
Measuring   Range: 35m 
Aerials: The Horn Antenna
Frequency: 6 GHz
Temperature: (-40 ~ 250)
Measurement   Precision:  ±10mm 
Process   Pressure: (-0.1 ~ 4) Mpa
The signal   Output: (4 ~ 20) mA/HART 
The Scene   Display: Four LCD /Can be   programmed
Power   Source: Two-wire (DC24V) Four-wire (DC24V/AC220V) 
Repeatability: ± 1mm 
Outer   Covering : Aluminum   /Plastic 
Connection: Flange (optional)

Kaidi Sensors digital radar level meter factory for detecting-1

1.   Dimensions  of  Instruments

l  Horn antenna size (unit: mm)


Kaidi Sensors digital radar level meter factory for detecting-2

l  Horn size (unit: mm)

Kaidi Sensors digital radar level meter factory for detecting-3

l  Flange Selection (unit: mm)

Kaidi Sensors digital radar level meter factory for detecting-4

2.The  Electrical  Connection 

l  The power supply voltage:


(4~20)mA/HART   (Two wire system)       The power   supply and the output current signal sharing a two core shield cable. The   supply voltage range see technical data. For intrinsically safe type must be   a safety barrier between the power supply and the instrument.
(4~20)mA/HART(Four wire   system)      Separate power   supply and the current signal, respectively using a two-core shielded cable.   The supply voltage range see technical data.
   
RS485 /   ModbusPower   supply and Modbus signal line are separated, respectively using a two-core   shielded cable, the power supply voltage range see technical data.

l  Connection  mode:

Ø 
24V two wire wiring diagram as follows:

 Kaidi Sensors digital radar level meter factory for detecting-5

Ø 
220V four wire connection is as below:

 

 Kaidi Sensors digital radar level meter factory for detecting-6

Ø  24V RS485/Modbus wiring diagram as follows:

Kaidi Sensors digital radar level meter factory for detecting-7

3.   Programming and  Debugging

l  Display / Keyboard:

Please debug the instrumentation by four buttons on the display screen. There are three debug menu languages optional. After debugging is generally used only for display, through the glass window can read measured value very clearly.

Display / Keyboard :

Kaidi Sensors digital radar level meter factory for detecting-8

l  PC debugging:

Connected to PC by HART:

Kaidi Sensors digital radar level meter factory for detecting-9

l  HART  handheld  programmer:

Kaidi Sensors digital radar level meter factory for detecting-10

4.   Technical   Parameters

General   data    
Materials 
Antenna                                               PTFE, PP
Outer   Covering                                   Aluminum, Plastic,   Anti-static PP, Stainless steel 316
The seal   housing and the housing       Silicone Rubber 
Shell   window                                       Polycarbonate
Ground   terminal                                   Stainless steel
Process   connection  
803Stainless Steel   Flanges
Supply voltage  
Two-wire        
Standard                                       (1626)V DC
Intrinsically   Safe                           (21.626.4)V DC
Power   Consumption                      Max.22.5mA 
Allowable   ripple 
<100HzH47Uss < lV
- (100100K)Hz   Uss < l0mV
Flameproof
(22.8 ~ 26.4)   V DC       2-wire system
(198 ~242)V   AC   4-wire system / 110V AC    4-wire system 
Power   Consumption  Max.  1VA1W


 Cable parameters      
Cable entry / plug                         1 M20xl.5 cable entry (cable diameter   5 ~ 9mm)
1 blind blocking M20xl.5
Spring   terminals                            For wire   cross-section 2.5mm²



Output   parameters      
The output signal                             (4~20)mA / HART
Resolution                                   1.6μA
Fault   signal                                     Current output   unchanged;20.5mA;22mA;3.9mA
Two-wire load   resistor                    See below
Four-wire   resistive load                  The maximum 500Ω
Integration   time                                (0 ~ 36) s,   adjustable

Kaidi Sensors digital radar level meter factory for detecting-11


Kaidi Sensors digital radar level meter factory for detecting-12












digital radar level meter High-quality materials are used, combined with advanced technology for processing, so that all aspects such as quality and performance can reach national standards.
Guangdong Kaidi Energy Technology Co., Ltd. The pursuit of excellence, adhere to the use of advanced concepts, high-quality materials and exquisite craftsmanship digital radar level meter, effectively guarantee the rationality of the structure digital radar level meter and the stability of performance, the quality is trustworthy.
We not only have an independent production workshop, advanced production equipment, professional production personnel and multiple automated production lines, but also have established a set of scientific and rigorous quality control system to ensure that the digital radar level meter produced are of high quality.
Guangdong Kaidi Energy Technology Co., Ltd. Actively study and introduce world-class management theories, establish a comprehensive quality management system, and implement the concept of product quality control throughout the entire process of product design, production, inspection, and use, and carry out quality control with full participation, It is better to ensure that the digital radar level meter produced is always of consistent quality and excellent quality.
Guangdong Kaidi Energy Technology Co., Ltd.The production strength is strong, the management system is perfect, and the digital radar level meter produced are all selected high-quality materials, which are manufactured by advanced technology and fine processing, with excellent workmanship and high quality, which are both beautiful and practical.
Its certified quality is a highlight. It is produced following the rules of the international quality certification system and has passed related quality certification. It can be designed with different skin color to cater to the clothing styles
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...