The precise control of installation details for magnetic float level gauges is crucial to ensuring accurate measurement and stable operation. The following provides a detailed explanation of installation control specifics for magnetic float level gauges:I. Installation DetailsVertical Installation: The gauge must be installed in a vertical orientation to ensure smooth operation of the magnetic float. Non-vertical installation may cause float jamming or measurement inaccuracies.Installation Location: Position the gauge in an easily observable and accessible location, whilst avoiding environments subject to excessive vibration or significant temperature fluctuations.Ball Valve Installation: A ball valve should be fitted between the gauge and the vessel's connecting pipe to facilitate subsequent cleaning and maintenance.II. Magnetic Material ControlKeep away from magnetic substances: Any magnetic materials should be kept distant from the magnetic flip-plate level gauge to prevent interference with its normal operation.Prohibit wire fastening: When securing the magnetic flip-plate level gauge, magnetic materials such as iron wire must not be used. Instead, non-magnetic materials like stainless steel clamps should be employed.III. Medium RequirementsMedium cleanliness: The measured medium must be free of solid impurities and magnetic substances to prevent impact resistance on the float or interference with the flipping of the magnetic flip plates.Medium Temperature:Excessively high or low medium temperatures may affect the measurement accuracy of the magnetic flip plate level gauge and the service life of the float. Therefore, when selecting a magnetic flip plate level gauge, the medium's temperature range should be considered, and the corresponding insulated or high-temperature resistant type should be chosen.IV. Commissioning and MaintenanceMagnetic Calibration: Prior to operational use, the magnetic flip-plate level gauge must be calibrated using a magnet to ensure the display shows red below zero and white above zero.Commissioning Procedure: When commissioning the gauge, first open the upper connecting pipe valve. Then slowly open the lower valve to allow the medium to permeate steadily into the main gauge tube. After confirming correct flipping of the magnetic indicators, close the lower feed pipe valve and open the drain valve to lower the liquid level in the main pipe. Repeat this procedure three times. Once the display is accurate after each operation, the gauge may be put into actual operation.Periodic Inspection: Conduct regular inspections and maintenance of the magnetic flip-plate level gauge. This includes checking for float jamming, ensuring smooth flipping of the magnetic indicators, and verifying that all connections remain secure.V. Additional ConsiderationsRemote Transmitter Installation: When fitted with a reed switch remote transmitter, ensure it is tightly secured against the main gauge tube using stainless steel clamps. The sensing surface of the reed switch transmitter must face and be flush against the main tube, with its zero point aligned horizontally with the zero indication of the magnetic flip-plate level gauge.Cable Protection: The connection cable between the reed switch remote transmitter and the display instrument or industrial control computer should be laid through a separate protective conduit or using a shielded two-core cable to ensure stable signal transmission.In summary, the process control details for magnetic flip-plate level gauges encompass multiple aspects including installation, magnetic material control, medium requirements, commissioning and maintenance, and other considerations. Only by strictly adhering to these detailed requirements for control and operation can the accurate measurement and stable operation of the magnetic flip-plate level gauge be ensured.
Read More>>
All Products
- Quality PRODUCT Exporter
- PRODUCT Supplier
- Quality PRODUCT For sell
- Best PRODUCT
- Hot PRODUCT
-
Hot PRODUCT Wholesale
-
Hot Accessories
- Hot Temp & Press Instrument
-
Hot Conveyor Belt Safety Switches For sell
- Best Flow Instrument Company
-
Level Instrument Manufacturer
- Buy Radar Level Meter
- Buy 80GFM Radar Level Meter
- 26GHz Radar Level Meter Wholesale
- Top Magnetic Level Gauge
- Best Magnetic Level Gauge Bulk
- Quality Vibrating Fork Level Switch Warranty
- Hot Rotary Paddle Level Switch
- Float Level Switch Bulk
- Level Switch Warranty
- Certificated Ultrasonic Level Meter
- Radar Level Meter Exporter
-
Hot Accessories
- Customized PRODUCT Wholesale
- Certificated PRODUCT
-
PRODUCT Warranty
-
Best Vibrating Fork Level Switch Manufacturer
-
Electromagnetic Flow Meter Factory
-
Top Conveyor Belt Safety Switches
-
Tuning fork switch For sell
-
Certificated Rotary Paddle Level Switch
-
Customized Float Level Switch
-
Hot Ultrasonic Level Meter
-
Buy Radar Level Meter Supplier
-
Customized Level Switch
-
Top Flow Meter Wholesale
-
Customized Rotary Paddle Level Switch
-
Hot Level Switch Wholesale
-
Buy Flow Meter
-
Pressure transmitter Warranty
-
Hot Temperature transmitter
-
Radar Level Meter Wholesale
-
Certificated Magnetic Level Gauge Company
-
Level Ultrasonic Company
-
Radar Level Meter Manufacturer
-
Certificated Magnetic Level Gauge
-
Best Level Switch
-
Certificated Level Ultrasonic
-
Radar Level Meter Supplier
-
Certificated Radar Level Meter
-
Glass level indicator Bulk
-
Magnetic Level Gauge Bulk
-
Best Temperature transmitter
-
Certificated Level Switch
-
Customized Conveyor belt safety switches
-
Flow Meter Warranty
-
Hot Flow Meter
-
Quality Level Transmitter Manufacturer
-
Buy Pressure transmitter For sell
-
Customized Magnetic Level Gauge
-
Best Magnetic Level Gauge and parts
-
Best Magnetic Level Gauge and parts For sell
-
Best Vibrating Fork Level Switch Manufacturer
- Top PRODUCT Warranty
Hot products