Kaidi Sensors  >  AI - Page Sitemap  >  high-quality radar type level transmitter manufacturers for work
high-quality radar type level transmitter manufacturers for work

high-quality radar type level transmitter manufacturers for work
  • high-quality radar type level transmitter manufacturers for work
  • high-quality radar type level transmitter manufacturers for work
  • high-quality radar type level transmitter manufacturers for work
  • high-quality radar type level transmitter manufacturers for work
  • high-quality radar type level transmitter manufacturers for work
  • high-quality radar type level transmitter manufacturers for work
  • high-quality radar type level transmitter manufacturers for work

high-quality radar type level transmitter manufacturers for work

Kaidi Sensors radar type level transmitter will be inspected in a strict manner. It's checked by a visual or technology approach to see whether it has untrimmed thread, shading variance, loose needle left in the garment, and other defections. This product can be used in many different industries such as food & beverage, water, energy, pharmaceutical, etc
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

Application:

6GHz radar level gauge is suitable for liquid, paste, granule and block material level and non-contact measurement, suitable for changes in temperature, pressure big; there is an inert gas and volatile.

The measurement method of microwave pulse, can work normally in the industrial frequency band range. The beam energy is low, can be installed on all kinds of metal, non-metallic container or pipe, no harm to human body and environment.


Suitable   for Medium: Liquid, especially for corrosive liquid
Explosion-proof   Grade:  Exia IIC T6 Ga/ Exd IIC T6 Gb
Measuring   Range: 20m 
Aerials: The Rod Antenna   (PTFE)
Frequency: 6 GHz
Temperature: -40~130
Measurement   Precision:  ±10mm 
Process   Pressure: (-0.1 ~ 1.6) Mpa
The signal   Output: (4 ~ 20) mA/HART 
The Scene   Display: Four LCD /Can be   programmed
Power   Source: Two-wire (DC24V) Four-wire (DC24V/AC220V) 
Repeatability: ± 1mm 
Outer   Covering : Aluminum /Plastic   /Stainless steel 
Connection:  With PTFE plate flange

high-quality radar type level transmitter manufacturers for work-1


high-quality radar type level transmitter manufacturers for work-2

1.   Dimensions  of  Instruments

l  The rod antenna radar size (unit: mm)

high-quality radar type level transmitter manufacturers for work-3

l 
The rod antenna radar size (unit: mm)

high-quality radar type level transmitter manufacturers for work-4

l  Horn antenna size (unit: mm)

high-quality radar type level transmitter manufacturers for work-5

l  Horn size (unit: mm)

high-quality radar type level transmitter manufacturers for work-6

l  Flange Selection (unit: mm)

high-quality radar type level transmitter manufacturers for work-7

2.   The  Electrical  Connection

l  The power supply voltage:


(4~20)mA/HART   (Two wire system)       The power supply and the output current signal sharing a two core   shield cable. The supply voltage range see technical data. For intrinsically   safe type must be a safety barrier between the power supply and the   instrument.
(4~20)mA/HART(Four wire   system)       Separate power supply and   the current signal, respectively using a two-core shielded cable. The supply   voltage range see technical data.
RS485 / ModbusPower   supply and Modbus signal line are separated, respectively using a two-core   shielded cable, the power supply voltage range see technical data.


l  Connection  mode:

Ø 
24V two wire wiring diagram as follows:

 

high-quality radar type level transmitter manufacturers for work-8


Ø 
220V four wire connection is as below:

 

high-quality radar type level transmitter manufacturers for work-9

Ø  24V RS485/Modbus wiring diagram as follows:


high-quality radar type level transmitter manufacturers for work-10

Explosion Proof Connection

The intrinsic safety version sensors (Exia IIc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia IIc T6.

A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: Exia IIC, voltage of power supply: 24V DC±5%, short-circuit current: 135mA, operating current: 4...20mA.

All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor0.1μF/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used.


high-quality radar type level transmitter manufacturers for work-11

l  Protection  grade:


This instrument meets the protection class IP66/67 requirements, please ensure the waterproof cable sealing head. The following diagram:

high-quality radar type level transmitter manufacturers for work-12

3.   Programming and  Debugging


l  There are three kinds of debugging method:

1)     Display / Keyboard  

2)     Host debugging  

             3)    HART handheld programmer

      l  Display / Keyboard:

Please debug the instrumentation by four buttons on the display screen. There are three debug menu languages optional. After debugging is generally used only for display, through the glass window can read measured value very clearly.

Display / Keyboard

high-quality radar type level transmitter manufacturers for work-13

l  PC debugging:

        Connected to PC by HART

high-quality radar type level transmitter manufacturers for work-14

l  HART  handheld  programmer:

high-quality radar type level transmitter manufacturers for work-15


4.   Technical   Parameters


General   data    
Materials 
Antenna                                               PTFE, PP
Outer   Covering                                   Aluminum, Plastic,   Anti-static PP, Stainless steel 316
The seal   housing and the housing       Silicone Rubber 
Shell   window                                       Polycarbonate
Ground   terminal                                   Stainless steel
Process   connection  
801G1½A Thread & 1½NPT Thread / Flange (optional) 
802With PTFE plate   flange
803Stainless Steel   Flanges
804Stainless Steel   Flanges
805Stainless Steel   Flanges
806Stainless Steel   Flanges
Supply voltage  
Two-wire        
Standard                                       (1626)V DC
Intrinsically   Safe                           (21.626.4)V DC
Power   Consumption                      Max.22.5mA 
Allowable   ripple 
<100HzH47Uss < lV
- (100100K)Hz   Uss < l0mV
Flameproof
(22.8 ~ 26.4)   V DC       2-wire system
(198 ~242)V   AC   4-wire system / 110V AC    4-wire system 
Power   Consumption  Max.  1VA1W

 Cable parameters      
Cable entry / plug                         1 M20xl.5 cable entry (cable diameter   5 ~ 9mm)
1 blind blocking M20xl.5
Spring   terminals                            For wire   cross-section 2.5mm²



Output   parameters      
The output signal                             (4~20)mA / HART
Resolution                                   1.6μA
Fault   signal                                     Current output   unchanged;20.5mA;22mA;3.9mA
Two-wire load   resistor                    See below
Four-wire   resistive load                  The maximum 500Ω
Integration   time                                (0 ~ 36) s,   adjustable

high-quality radar type level transmitter manufacturers for work-16


high-quality radar type level transmitter manufacturers for work-17














 

 







Kaidi Sensors radar type level transmitter is manufactured complying with the strictest quality regulations for garments. These requirements mainly include National Basic Safety Technical Specifications for Textile Products (GB18401-2010) and Instruction Use for Textiles and Garments (GB5296.4-1998). This product can repeat the same measurement many times
Kaidi Sensors radar type level transmitter undergoes a series of quality tests. They include symmetry check of fabrics, colorfastness, adhesive check (logos, tag, care labeling), stitch damage check, etc. With a simple structure, it is perfectly good for demanding industrial applications
Kaidi Sensors radar type level transmitter is verified by on-site tests. These tests include fitting testing, dry & wet crocking testing, seam strength testing, and fatigue testing. This product is characterized by excellent temperature stability
Kaidi Sensors radar type level transmitter is designed from the perspectives of structural and decorative levels. Structural design includes elements of shape, color, and lines, while decorative design concerns the aesthetics, such as printing. This product can be used in many different industries such as food & beverage, water, energy, pharmaceutical, etc
The production processes of Kaidi Sensors radar type level transmitter are as followed. They are fabric cutting, printing, sewing, thread trimming, washing, ironing, folding, and packing. This product is not susceptible to cracks
radar type level transmitter has the characteristic of radar type level transmitter, it has an extensive application prospect. Its power ratings can be customized e based on requests
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...