Maintenance and maintenance of electromagnetic flow meter in shutdown state

by:Kaidi Sensors     2022-08-15
Abstract: The maintenance and maintenance information of the electromagnetic flowmeter in the shutdown state is provided by the excellent flowmeter and flowmeter manufacturers and quotation manufacturers. When the electromagnetic flowmeter is not in use, we must take scientific and reasonable maintenance and maintenance methods for the electromagnetic flowmeter. When the technicians of Jiangsu Xudong Instrument Factory provide electromagnetic flowmeter technical services to users, they often encounter users purchasing electromagnetic flow. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the maintenance and maintenance articles of electromagnetic flowmeters in the state of shutdown. When the electromagnetic flowmeter is not in use, we must take scientific and reasonable maintenance and maintenance methods for the electromagnetic flowmeter. When the technicians of Xudong Instrument Factory provide users with electromagnetic flowmeter technical services, they often encounter that users find inaccurate measurement data after purchasing and using the electromagnetic flowmeter for a period of time. In fact, this is not the quality problem of the electromagnetic flowmeter itself. Because the user did not follow the after-use maintenance and maintenance methods in the manual. Below we analyze for you how to properly and effectively maintain and maintain the electromagnetic flowmeter when the electromagnetic flowmeter is not used. 1. Zero point inspection and adjustment of electromagnetic flowmeter maintenance: Before the electromagnetic flowmeter is put into operation, the zero point must be adjusted when the electromagnetic flow sensor is full of liquid and static after power-on. After being put into operation, it is also necessary to periodically stop the flow for zero-point inspection according to the conditions of use; especially for precipitation, easily polluted electrodes, and non-cleaning liquids containing solid phase, more inspections should be carried out in the early stage of operation to gain experience to determine the normal inspection cycle. Compared with the rectangular wave shock, the electromagnetic flowmeter of the AC excitation method is more prone to zero drift, so more attention should be paid to inspection and adjustment. Give two examples of application errors where the deposited layers fail. One is that in oil drilling and cementing engineering, the total flow of cement slurry is an important process parameter, and high-pressure electromagnetic flowmeters are often used. The instrument is used intermittently. After use, rinse the sensor measuring tube with clean water, and the remaining time is empty. Due to the incomplete cleaning, the residual cement slurry on the inner wall of the measuring tube solidified into a thin layer, which accumulated to form an insulating layer in the past two months, covering the entire electrode surface, resulting in abnormal operation and eventually unable to work. The other is the electrolytic cutting process test device. The electromagnetic flowmeter is used to control the flow of saturated brine. After a period of intermittent use, it is found that the flow signal gradually weakens, and the signal is zero after 2 months. The reason is that iron oxide deposits on the tube wall during the electrolytic cutting process, resulting in a short circuit. Clear the stratification and return to normal immediately. 2. Regularly check the electrical performance of the sensor for the maintenance of the electromagnetic flowmeter: First, roughly measure the resistance between the electrodes. Disconnect the signal connection between the sensor and the converter, fill the sensor with liquid, measure the resistance between the two electrodes and the ground terminal with a multimeter, whether it is within the range specified by the manufacturer, and the two measured values ​​are roughly the same. Record the resistance value of the first measurement, which is useful for later determining the cause of the sensor failure (such as whether the deposited layer is conductive or insulating). Next, empty the sensor of the liquid, wipe the inner wall, and measure the resistance between the two electrodes and the ground terminal with a megohmmeter after it is completely dry. Finally, check the insulation resistance of the excitation coil, remove the sensor excitation coil, wire the terminal to the converter, and measure the insulation resistance of the coil with a megohmmeter. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Maintenance and Maintenance of Electromagnetic Flow Meter in Shutdown State'
is a modern level gauge widely used in customized level indicator industry. It also enhances the quality customized level indicator value of the products.
Guangdong Kaidi Energy Technology Co., Ltd. are a market-focused, process-centered organization that develops and delivers innovative solutions to our customers, consistently outperforms our peers, produces predictable earnings for our customers, and provides a dynamic and challenging environment for our employees.
can be used in a wide variety of ways.
customized level indicator level gauge offer a wide range of customized level indicator and gave the user the choice of customized level indicator, customized level indicator and customized level indicator.
Rewards and discount programs give customers more reason to come back for level gauge again, especially in the competitive retail and services markets.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...