I. Introduction to the principle of magnetic flap level meterLiquid level measurement is a crucial aspect in the industrial field. As an intuitive and reliable level measurement tool, magnetic flap level gauges are widely used in a variety of tanks and vessels. However, in some complex application scenarios, it may be necessary to match other types of level meters to provide more comprehensive and accurate measurement data. Magnetic Flip Flop Level Gauges are designed to visually display the liquid level height in red and white color boundaries by moving the magnetic float up and down in response to changes in the liquid level, thus driving the magnetic flip flop on the panel to flip. This kind of liquid level meter has the advantages of simple structure, intuitive observation, easy installation and so on.Magnetic Flip Plate Level Gauges are used in a wide range of applications for level measurement of various media, e.g. oils, acids and alkalis, emulsions, sewage etc.II. Common Types of Matching Level Meters1. Float Level Gauge: Float Level Gauge measures the liquid level by moving the float with the liquid level change, thus changing the resistance or inductance value in the circuit. Compared with magnetic flap level meter, float level meter is more suitable for long-distance transmission and automatic control system.2. ultrasonic level meter: ultrasonic level meter utilizes the propagation time of ultrasonic waves in the liquid to measure the liquid level. It has the advantages of non-contact measurement, high precision and fast response speed. Used in conjunction with magnetic flap level meter, it can provide accurate liquid level data in harsh environments.III. Whether it needs to be equipped with an additional level transmitterAlthough the magnetic flip-flop level meter can directly output the switching signal, but in the practical application, if you need to realize the continuous liquid level change monitoring, you need to use the magnetic flip-flop level meter with the liquid level transmitter.Level transmitter is a physical quantity can be converted into a standard signal output transmitter, through the transmitter can be obtained by the magnetic flip-flop level meter signal into a standard current or voltage signal, and according to the need for inversion, filtration, amplification and other processing, the output of 4-20mA or 0-5V signals, so as to achieve the purpose of real-time monitoring of liquid level changes.Therefore, usually, the use of magnetic flap level meter needs to be equipped with level transmitter.IV. Selection principle of liquid level transmitterLevel transmitter selection needs to be based on the actual application requirements, generally need to consider the following aspects:(1) Measuring range: Generally, there should be a margin to grasp the upper and lower limits of the liquid level;(2) precision requirements: such as the requirements of high precision, level transmitter precision should also be adapted to improve;(3) Installation: including the location of the installation, connection, etc., need to be consistent with the actual application requirements;(4) Environmental adaptability: such as the medium temperature, pressure, corrosivity and other effects on the use of level transmitters, the need to choose to adapt to the model;(5) maintenance and repair needs: level transmitter use for a period of time also need to maintain and repair, should consider product quality and manufacturers of after-sales service and other factors.V. Selecting the right level meter combinationWhen choosing magnetic flap level meter and its matching level meter, the following factors need to be considered:1. Measurement accuracy: select the level meter combination with appropriate accuracy according to the actual demand.2. Environmental conditions: Consider the working environment of the level meter, such as temperature, pressure, corrosiveness and other factors, and choose the level meter that can adapt to these conditions.3. Installation and maintenance: Select a level meter combination that is easy to install and has low maintenance costs to reduce operating costs.4. Budget: under the premise of meeting the measurement needs, choose a cost-effective level meter combination.In summary, magnetic flap level meter and its matching level meter play an important role in industrial liquid level measurement. Selecting a suitable level meter combination is crucial to ensure the smooth progress of industrial production. By comprehensively considering factors such as measurement accuracy, environmental conditions, installation and maintenance costs and budget, you can choose the most suitable level measurement program for your enterprise.VI. SummaryMagnetic flap level meter and level transmitter used in conjunction, can realize the continuous monitoring of liquid level changes, widely used in industrial fields of liquid level measurement and process control. In the purchase of level transmitter, need to be based on the actual application requirements for a detailed understanding and comparison, in order to ensure product performance and quality at the same time, improve the application of benefits.
Read More>>