Aluminum Alloy Material Aluminum Alloy Material Stainless Steel Material
The flow profile of the flow sensor is similar to the profile of a Venturi tube. A set of spiral guide vanes are placed on the inlet side. When the fluid enters the flow sensor, the guide vanes force the fluid to produce a violent vortex flow. When the fluid enters the diffusion section, the vortex flow is affected by the backflow and starts to make a second rotation, forming a gyroscopic vortex precession phenomenon. The precession frequency is proportional to the flow rate and is not affected by the physical properties and density of the fluid. The second rotation precession frequency of the fluid measured by the detection element can obtain good linearity in a wide flow rate range. The signal is amplified by the preamplifier. Filtering and shaping are converted into pulse signals proportional to the flow rate, and then sent to the microprocessor together with the temperature, pressure and other detection signals for integration processing, and finally the measurement results (instantaneous flow rate, cumulative flow rate) are displayed on the LCD screen. And temperature and pressure data)
➯ No mechanical moving parts, not easy to corrode, stable and reliable, long life, no special maintenance for long-term operation;
➯ Using 16-bit computer chip, high integration, small size, good performance, and strong functions of the whole machine;
➯ Intelligent flow meter set flow probe. The microprocessor, pressure and temperature transmitter are integrated, and the built-in combination is adopted to make the structure more compact. It can directly measure the flow, pressure and temperature of the fluid, and automatically track compensation and compression factor correction in real time;
➯ Adopting Chinese character dot matrix display, with many display digits, intuitive and convenient reading, it can directly display the volume flow in working state, the volume flow in standard state, the total amount, and the parameters such as medium pressure and temperature;
➯ The display instrument can output frequency pulses, 4-20mA analog signals, and has an RS485 interface, which can be directly networked with a microcomputer, and the transmission distance can reach 1.2km;
Executive standard | GB3836.1-2000/GB3836.2-2000 |
Verification regulations | Velocity flow meter (JJG198-1994) |
Accuracy grade | 1:40 |
Instrument material | 1.5 grade/1.0 grade |
Withstand voltage grade | Aluminum body (1.6MPa)≤DN150(6.3MPa); stainless steel (4.0MPa)>DN150(4.0MPa) |
Instrument material | Body: 304 stainless steel or cast aluminum Impeller: high-quality aluminum alloy Converter: cast aluminum |
Protection grade | IP65 |
Power supply | 24V+ battery |
Whole machine power consumption | External power supply: <2w; Internal power supply: average power consumption 1mW, which can be applied continuously for more than two years |
Real-time recording | Daily record, monthly record, fixed time interval record |
Explosion-proof grade | Exia II CT4 |
Nominal diameter DN mm | Type | Flow range m³/h | Operating pressure MPa | Accuracy grade | Repeatability |
15 | 1.0-10 | 1.6 2.5 4.0 6.3 10 16 | 1.0 1.5 | Less than 1/3 of the basic error limit | |
20 | 1.5-15 | ||||
25 | 3.0-30 | ||||
32 | 6.0~60 | ||||
40 | 7.0~70 | ||||
50 | Type A | 12~150 | |||
Type B | 2.5~75 | ||||
80 | Type A | 40~400 | |||
Type B | 10~200 | ||||
100 | Type A | 80~900 | |||
Type B | 30~600 | ||||
150 | Type A | 150~1500 | |||
Type B | 40~900 | ||||
200 | 240~3600 | 1.6;2.5;4.0 |
Please Send Us your Application details
Measuring range , medium, Installation method (flange, thread), Pressure range, Remote transmitter, Level alarm switch
More Model available for all appication, different termperture and pressure!
We are here to help you! If you close the chatbox, you will automatically receive a response from us via email. Please be sure to leave your contact details so that we can better assist