loading
Kaidi Sensors | Level gauge & level indicator manufacturer
KAIDI best intelligent radar level meter suppliers for detecting 1
KAIDI best intelligent radar level meter suppliers for detecting 2
KAIDI best intelligent radar level meter suppliers for detecting 3
KAIDI best intelligent radar level meter suppliers for detecting 4
KAIDI best intelligent radar level meter suppliers for detecting 5
KAIDI best intelligent radar level meter suppliers for detecting 1
KAIDI best intelligent radar level meter suppliers for detecting 2
KAIDI best intelligent radar level meter suppliers for detecting 3
KAIDI best intelligent radar level meter suppliers for detecting 4
KAIDI best intelligent radar level meter suppliers for detecting 5

KAIDI best intelligent radar level meter suppliers for detecting

Outer Covering::
5-10 days
Process temperature:
1 SET
Inquiry


Application:

6GHz radar level gauge is suitable for liquid, paste, granule and block material level and non-contact measurement, suitable for changes in temperature, pressure big; there is an inert gas and volatile.

The measurement method of microwave pulse, can work normally in the industrial frequency band range. The beam energy is low, can be installed on all kinds of metal, non-metallic container or pipe, no harm to human body and environment.

Suitable   for Medium:Liquid,   especially with pressure and Volatile Liquid
Explosion-proof   Grade:  Exia IIC T6 Ga/ Exd IIC T6 Gb
Measuring   Range: 35m 
Aerials: The Horn Antenna
Frequency: 6 GHz
Temperature: (-40 ~ 250)
Measurement   Precision:  ±10mm 
Process   Pressure: (-0.1 ~ 4) Mpa
The signal   Output: (4 ~ 20) mA/HART 
The Scene   Display: Four LCD /Can be   programmed
Power   Source: Two-wire (DC24V) Four-wire (DC24V/AC220V) 
Repeatability: ± 1mm 
Outer   Covering : Aluminum   /Plastic 
Connection: Flange (optional)

16116479757255.jpg

1.   Dimensions  of  Instruments

l  Horn antenna size (unit: mm)


1611648331(1).jpg

l  Horn size (unit: mm)

1611648531(1).jpg

l  Flange Selection (unit: mm)

1611648622(1).jpg

2.The  Electrical  Connection 

l  The power supply voltage:


(4~20)mA/HART   (Two wire system)       The power   supply and the output current signal sharing a two core shield cable. The   supply voltage range see technical data. For intrinsically safe type must be   a safety barrier between the power supply and the instrument.
(4~20)mA/HART(Four wire   system)      Separate power   supply and the current signal, respectively using a two-core shielded cable.   The supply voltage range see technical data.
   
RS485 /   ModbusPower   supply and Modbus signal line are separated, respectively using a two-core   shielded cable, the power supply voltage range see technical data.

l  Connection  mode:

Ø 
24V two wire wiring diagram as follows:

 1611649122(1).png

Ø 
220V four wire connection is as below:

 

 1611649185(1).png

Ø  24V RS485/Modbus wiring diagram as follows:

1611649236(1).png

3.   Programming and  Debugging

l  Display / Keyboard:

Please debug the instrumentation by four buttons on the display screen. There are three debug menu languages optional. After debugging is generally used only for display, through the glass window can read measured value very clearly.

Display / Keyboard :

803_14.jpg

l  PC debugging:

Connected to PC by HART:

1611649501(1).jpg

l  HART  handheld  programmer:

1611649588(1).jpg

4.   Technical   Parameters

General   data    
Materials 
Antenna                                               PTFE, PP
Outer   Covering                                   Aluminum, Plastic,   Anti-static PP, Stainless steel 316
The seal   housing and the housing       Silicone Rubber 
Shell   window                                       Polycarbonate
Ground   terminal                                   Stainless steel
Process   connection  
803Stainless Steel   Flanges
Supply voltage  
Two-wire        
Standard                                       (1626)V DC
Intrinsically   Safe                           (21.626.4)V DC
Power   Consumption                      Max.22.5mA 
Allowable   ripple 
<100HzH47Uss < lV
- (100100K)Hz   Uss < l0mV
Flameproof
(22.8 ~ 26.4)   V DC       2-wire system
(198 ~242)V   AC   4-wire system / 110V AC    4-wire system 
Power   Consumption  Max.  1VA1W


 Cable parameters      
Cable entry / plug                         1 M20xl.5 cable entry (cable diameter   5 ~ 9mm)
1 blind blocking M20xl.5
Spring   terminals                            For wire   cross-section 2.5mm²



Output   parameters      
The output signal                             (4~20)mA / HART
Resolution                                   1.6μA
Fault   signal                                     Current output   unchanged;20.5mA;22mA;3.9mA
Two-wire load   resistor                    See below
Four-wire   resistive load                  The maximum 500Ω
Integration   time                                (0 ~ 36) s,   adjustable

803_18.jpg


803_20.jpg












Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.

CONTACT US

Attn: Mr. Joe Zou
Email:info86kd@gmail.com | info@kaidi86.com
Tel: +86 756 8652289
Fax: +86 756 8652290
Mob: +86 18198790863 (whatsapp/Wechat Same Number)
Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

BETTER TOUCH BETTER BUSINESS

Contact Sales at KAIDI level gauge manufacturer.

Copyright © 2026 KAIDI | Sitemap | Privacy Policy
Customer service
detect