When many friends need to use a flow meter on site, they usually think of a flow meter as an electromagnetic flow meter, which is the most frequently used flow meter among the flow meters. So many people will also wonder what electromagnetic flowmeter 150 represents? In fact, 150 of electromagnetic flowmeter 150 represents the caliber. Let's take everyone into the world of electromagnetic flowmeter 150. Electromagnetic flowmeters have their own caliber requirements during use. Under certain working conditions, the electromagnetic flowmeter 150 is still used a lot. In the production process of the electromagnetic flowmeter 150, the requirements for the overall strength of the manufacturer will be relatively high. From the composition of the electromagnetic flowmeter, the material of the electromagnetic flowmeter, the lining requirements of the electromagnetic flowmeter, the requirements for the electrode of the electromagnetic flowmeter, etc. It is a barrier to test the strength of a manufacturer. The electromagnetic flowmeter DN150 has this specific requirement for the electromagnetic flowmeter itself during use. 1. Electrode contact resistance. Measuring the liquid contact resistance of the electrode spoon can indirectly evaluate the general condition of the electrode and the lining surface without removing the flow
sensor from the pipeline, which is helpful to analyze the cause of the failure. 2. Polarization voltage of the electrode. Measuring the polarization voltage between the electrode and the liquid will help determine whether the zero point instability or the output shaking failure is caused by the electrode being contaminated or covered. Use the 2V DC gear of the digital multimeter to measure the polarization voltage between the two electrodes and the ground (the electromagnetic flowmeter can be measured without or without power failure). If the two measured values u200bu200bare nearly equal, the electrode is not contaminated or covered. The polarization voltage is determined by the 'electrode potential' of the electrode material and the properties of the liquid, and the measured value may be between several mV to several hundred mV. In fact, the contamination of the two electrodes during operation cannot be completely symmetrical, so the voltage on the two electrodes forms an asymmetric common-mode voltage. The asymmetric common-mode voltage becomes a differential-mode signal, causing a zero offset. 3. Judging the direction of pipeline stray current flow. Sometimes to find the source of stray interference in the pipeline is upstream or downstream of the flow sensor, in order to narrow the search range and try to reduce or eliminate the influence of stray current interference. 4. Measurement of signal cable interference. The signal cable is subject to external electrostatic induction and electromagnetic induction interference, which will cause the zero point of the electromagnetic flowmeter to change. In order to judge whether the zero point change is affected by the signal cable interference potential, it is necessary to determine the general range of the interference and the degree of influence on the electromagnetic flowmeter. 5. Measure the presence or absence of ground potential. During the normal use of the electromagnetic flowmeter, if the state of the motor (force) near the sensor changes (such as leakage), the ground potential will change and cause the zero point to change. To check whether there is any influence in this respect, short-circuit the working grounding terminal C of the converter and the protective grounding terminal, and judge whether there is a grounding potential by the change of the zero point (or the indicated value). The electromagnetic flowmeter is simply composed of a flow sensor transmitter. The installation requirement of the electromagnetic flowmeter is that it must be installed at the lowest point of the pipeline or the vertical section of the pipeline, but it must be in the case of full pipe. The straight pipe section requires the first 5D and then 3D, so as to ensure the electromagnetic flowmeter. Use and accuracy requirements. At present, there are many manufacturers of electromagnetic flowmeter 150 in China, so the editor will also introduce to you one, Kaidi electromagnetic flowmeter 150 caliber, from the materials used in production, environment, personnel, and the calibration system and aging in the calibration process. On the installation, it is also more attentive. Moreover, Kaidi has more than 20 offices across the country, which can solve technical problems for you around the clock, so you have no worries!
Guangdong Kaidi Energy Technology Co., Ltd. have now make a decision to enlarge our company in other countries.
KAIDI provides supreme quality and ultimate using experience.To know in detail about the prices please visit Kaidi level indicator.
Offering a loyalty program not only makes customers feel valued, but it allows Guangdong Kaidi Energy Technology Co., Ltd. to easily collect important information about customers.
There have been conclusive evidence on 's role in customized level indicator and customized level indicator.