Kaidi Sensors  >  AI - Page Sitemap  >  custom intelligent radar level meter suppliers for industrial
custom intelligent radar level meter suppliers for industrial

Custom intelligent radar level meter suppliers for industrial

Application:
Charge level measurement of high furnace
Measuring Range:
Measurement of solids, especially media at high temperatures
Accuracy:
The Horn Antenna
Frequency:
6 GHz
Explosion proof certification:
Exia IIC T6 GA/Exd IIC T6 GB
Outer Covering:
15m
Process temperature:
(-40 ~ 130)℃
MOQ
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Product Information of custom intelligent radar level meter suppliers for industrial
Company Advantages
1. The fashionable design of intelligent radar level meter allows customers to enjoy the aesthetics. Since it is maintenance-free, this product significantly helps save operation costs
2. Paying more attention to the quality of intelligent radar level meter will contribute to the brand image establishment of KAIDI. The function of this product can be customized to meet the needs of liquids, granules, slurries, solids, and powder
3. Our intelligent radar level meter boasts its fabulous properties of . This product can repeat the same measurement many times

PRODUCT OVERVIEW

6GHz intelligent series radar level meter is suitable for non-contact continuous measurement of the level of liquid slurry, particle material and block material, suitable for large temperature and pressure changes;

The microwave pulse measurement method is used in the presence of inert gas and volatiles, and can work normally in the range of industrial frequency band. The beam energy is low, and can be installed in various metal and non-metal containers or pipelines, which does no harm to human body and the environment.


custom intelligent radar level meter suppliers for industrial-1


THE PRODUCT PRINCIPLE

Antenna system to launch and microwave receiving energy is very low, very short pulse. Radar waves travel with the speed of light. The running time can be through the electronic components are converted into a signal. Measurement of this special time extension method can realize stable, accurate in a very short period of time.

Even if the condition is very complex, the presence of false echo, with the latest micro- processing technology and debugging software also can analyze the level echo accurately.

custom intelligent radar level meter suppliers for industrial-2

Microwave antenna to receive the reflected pulse and transmitted to the electronic circuit, a microprocessor to signal processing, to identify the micro pulse generated on the material surface echo. Echo recognition is completed by the pulse system, the accuracy can reach millimeter level. From the material surface distance between D and T pulse is proportional to the time travel: D=C×T/2 Where C is the speed of light Because of the air tank is a known distance E, L: L=E-D By setting the empty tank height E (= zero), the full height of F (= full scale) and some application parameters, application parameters automatically makes the instrument to measure the environment. 4 - 20mA with a corresponding output.

PROTECTION GRADE

This instrument meets the protection class IP66/67 requirements, please ensure the waterproof cable sealing head. The following diagram:

custom intelligent radar level meter suppliers for industrial-3

How to install to meet the requirements of IP67: 

Please make sure that the sealing head is not damaged. 

Please make sure that the cable is not damaged. 

Please make sure that the cable for use with electrical connection specification. 

Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the① 

Tighten the cable seal head, see the② 

Please electrical interface will not use blind plug tight, see the

PRODUCT SPECIFICATION


custom intelligent radar level meter suppliers for industrial-4


APPEARANCE OF SIZE


custom intelligent radar level meter suppliers for industrial-5

TECHNICAL PARAMETERS

custom intelligent radar level meter suppliers for industrial-6

custom intelligent radar level meter suppliers for industrial-7

custom intelligent radar level meter suppliers for industrial-8


custom intelligent radar level meter suppliers for industrial-9

INSTALLATION REQUIREMENTS


custom intelligent radar level meter suppliers for industrial-10

 The recommended position (2), the outer wall of tank wall to install pipe shall 

meet the following from the tank wall best distance to tank diameter of 1/4 or 1/6, 

the minimum distance from the installation of tank wall as the measurement range of 1/10. 


For example: liquid level of storage tank 10mand the tank wall install the minimum distance of 1m.


Cannot be installed above the feeding port (4). 


Cannot be installed in the central position (3), if installed in the central, yield multiple false echo, clutter echo will lead to real signal loss. 


If you can't keep the instrument and the tank wall of the tank wall distance, the medium will adhesion caused by false echo, when debugging instrument should be false echo storage.


The top conical tank level, can be installed at the top of the tank is intermediate, 

can guarantee the measurement to the conical bottom. 


custom intelligent radar level meter suppliers for industrial-11custom intelligent radar level meter suppliers for industrial-12

A feed antenna to the vertical alignment surface. If the surface is rough, stack angle must be used to adjust the angle of Universal joint flange of the antenna to the alignment surface. 


(Due to the solid surface tilt will cause the echo attenuation, even Loss of signal.)


custom intelligent radar level meter suppliers for industrial-13

Tank installation instructions:


In the signal beam, should avoid the following installation: 

Such as: (1) the limit switch, temperature sensor. 

Symmetric devices such as (2): vacuum ring, a heating coil , Baffle plate etc. 

If the tank (1) (2) interference object, should be guided wave tube measurement.


Best installation options: 


Antenna size: larger antenna, beam angle smaller, interfering echoes will be weaker. 

Antenna adjustment: the antenna to adjust to the best measurement position.

Guided wave radar take over: The installation of the wave guide is used to avoid disturbing the echo.


Company Features
1. Guangdong Kaidi Energy Technology Co., Ltd. is one of the industry-leading manufacturers in China. We provide quality intelligent radar level meter based on extensive experience and in-depth product knowledge.
2. Our factory has been equipped with a wide range of advanced production facilities. This gives us a powerful capacity that automates tasks, streamlines workflow, and helps us quickly define and validate the form, fit, and function of our product.
3. Our goal is to improve the work environment for our people by promoting a safe and healthy workplace, reducing risks, preventing diseases and fostering their physical and psychological well-being.
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...