Application:
Liquid, especially for corrosive liquid
Measuring Range:
20m
Accuracy:
±10mm
Frequency:
6GHz
Process Pressure:
(-0.1~1.6)Mpa
Process Temperature:
-40℃~130℃
Explosion proof certification:
ExiaⅡCT6Ga/ExdⅡCT6Gb
Outer Covering:
Aluminum /Plastic /Stainless steel
Power supply
Two-wire (DC24V) 、Four-wire (DC24V/AC220V)
Signal output
4~20mA
MOQ
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Product Information of latest guided wave radar level transmitter manufacturers for work
Company Advantages
1. Different from common material, material for guided wave radar level transmitter gains the absolute advantage in characteristics of . This product is characterized by excellent temperature stability
2. Comfort could be a highlight when picking out this product. It can make people feel comfortable and let them stay for long. There is little variation between its measuring values
3. The product stands out for its low energy consumption. By adopting energy-saving technology, its ingenious circuit design can effectively minimize the loss of energy due to transient currents. This product can be used in many different industries such as food & beverage, water, energy, pharmaceutical, etc
4. The product has the advantage of scratch resistance. The scratch testing has been carried out to get an insight into materials to determine the resistance to abrasion and wear.
5. The product features safety and security. It has been thoroughly tested with various machines to make sure it is firm and robust enough. This product has a high level of insulation

Radar level meter working principle:

Radar level transmitters are electronic devices used to measure fluid levels. Radar technology is employed by these transmitters, taking advantage of the 10GHz electromagnetic waves of the microwave X-band bandwidth. Kaidi Sensors supply radar level meters which offer non-contact continuous monitoring of liquid, slurry, powder and solids. Radar sensors can remain accurate even when working temperatures and pressures fluctuate drastically. As these instruments emit low energy beams, they have no adverse effect on humans or the environment when installed in metal or non-metal tanks or pipes. Furthermore, radar level sensors feature a high signal to noise ratio for accurate (2mm) measurement despite rapidly changing levels; this is maintained by the narrow beam angle unaffected by angle of repose.

Radar level transmitters utilize top-down waveguides to send out microwave pulses directed into a containment vessel. Due to gas and vapor species' low dielectric constant, or relative permittivity (Er), these signals can propagate through the headspace. Upon hitting the abrupt change in dielectric between the headspace's reduced-dielectric medium and the elevated-dielectric liquid or solid surface, these pulses are reflected back to their source. An integrated timing system computes how much time is needed for these signales generated from the antennae to return, delivering exact digital precision level measurments based on the dielectric properties of the substance being monitored.


Advantages of radar level meter:

1. Interference echo can be suppressed

This function can be set in the radar transmitter, our radar level meter has digital display and easy operation buttons, users can set this function when needed.

2. The best part is that it can have solids level measurement which our SH series capacitance type level transmitters cannot achieve. It can measure ore level, and powder level in dusty environment.

3. Radar level meter can also be used in some high temperature and pressure conditions by choosing different kinds of precision digital level indicator.

4. Radar sensor can accurately measure level and be the measurement is continuous

This is mainly because the radar level meter signal wave is the electromagnetic wave, so it will not be affected by the environment and also the measurement can be non-contact.


Application:

6GHz radar level gauge is suitable for liquid, paste, granule and block material level and non-contact measurement, suitable for changes in temperature, pressure big; there is an inert gas and volatile.

The measurement method of microwave pulse, can work normally in the industrial frequency band range. The beam energy is low, can be installed on all kinds of metal, non-metallic container or pipe, no harm to human body and environment.


Suitable   for Medium: Liquid, especially for corrosive liquid
Explosion-proof   Grade:  Exia IIC T6 Ga/ Exd IIC T6 Gb
Measuring   Range: 20m 
Aerials: The Rod Antenna   (PTFE)
Frequency: 6 GHz
Temperature: -40~130
Measurement   Precision:  ±10mm 
Process   Pressure: (-0.1 ~ 1.6) Mpa
The signal   Output: (4 ~ 20) mA/HART 
The Scene   Display: Four LCD /Can be   programmed
Power   Source: Two-wire (DC24V) Four-wire (DC24V/AC220V) 
Repeatability: ± 1mm 
Outer   Covering : Aluminum /Plastic   /Stainless steel 
Connection:  With PTFE plate flange

latest guided wave radar level transmitter manufacturers for work-1


latest guided wave radar level transmitter manufacturers for work-2

1.   Dimensions  of  Instruments

l  The rod antenna radar size (unit: mm)

latest guided wave radar level transmitter manufacturers for work-3

l 
The rod antenna radar size (unit: mm)

latest guided wave radar level transmitter manufacturers for work-4

l  Horn antenna size (unit: mm)

latest guided wave radar level transmitter manufacturers for work-5

l  Horn size (unit: mm)

latest guided wave radar level transmitter manufacturers for work-6

l  Flange Selection (unit: mm)

latest guided wave radar level transmitter manufacturers for work-7

2.   The  Electrical  Connection

l  The power supply voltage:


(4~20)mA/HART   (Two wire system)       The power supply and the output current signal sharing a two core   shield cable. The supply voltage range see technical data. For intrinsically   safe type must be a safety barrier between the power supply and the   instrument.
(4~20)mA/HART(Four wire   system)       Separate power supply and   the current signal, respectively using a two-core shielded cable. The supply   voltage range see technical data.
RS485 / ModbusPower   supply and Modbus signal line are separated, respectively using a two-core   shielded cable, the power supply voltage range see technical data.


l  Connection  mode:

Ø 
24V two wire wiring diagram as follows:

 

latest guided wave radar level transmitter manufacturers for work-8


Ø 
220V four wire connection is as below:

 

latest guided wave radar level transmitter manufacturers for work-9

Ø  24V RS485/Modbus wiring diagram as follows:


latest guided wave radar level transmitter manufacturers for work-10

Explosion Proof Connection

The intrinsic safety version sensors (Exia IIc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia IIc T6.

A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: Exia IIC, voltage of power supply: 24V DC±5%, short-circuit current: 135mA, operating current: 4...20mA.

All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor0.1μF/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used.


latest guided wave radar level transmitter manufacturers for work-11

l  Protection  grade:


This instrument meets the protection class IP66/67 requirements, please ensure the waterproof cable sealing head. The following diagram:

latest guided wave radar level transmitter manufacturers for work-12

3.   Programming and  Debugging


l  There are three kinds of debugging method:

1)     Display / Keyboard  

2)     Host debugging  

             3)    HART handheld programmer

      l  Display / Keyboard:

Please debug the instrumentation by four buttons on the display screen. There are three debug menu languages optional. After debugging is generally used only for display, through the glass window can read measured value very clearly.

Display / Keyboard

latest guided wave radar level transmitter manufacturers for work-13

l  PC debugging:

        Connected to PC by HART

latest guided wave radar level transmitter manufacturers for work-14

l  HART  handheld  programmer:

latest guided wave radar level transmitter manufacturers for work-15


4.   Technical   Parameters


General   data    
Materials 
Antenna                                               PTFE, PP
Outer   Covering                                   Aluminum, Plastic,   Anti-static PP, Stainless steel 316
The seal   housing and the housing       Silicone Rubber 
Shell   window                                       Polycarbonate
Ground   terminal                                   Stainless steel
Process   connection  
801G1½A Thread & 1½NPT Thread / Flange (optional) 
802With PTFE plate   flange
803Stainless Steel   Flanges
804Stainless Steel   Flanges
805Stainless Steel   Flanges
806Stainless Steel   Flanges
Supply voltage  
Two-wire        
Standard                                       (1626)V DC
Intrinsically   Safe                           (21.626.4)V DC
Power   Consumption                      Max.22.5mA 
Allowable   ripple 
<100HzH47Uss < lV
- (100100K)Hz   Uss < l0mV
Flameproof
(22.8 ~ 26.4)   V DC       2-wire system
(198 ~242)V   AC   4-wire system / 110V AC    4-wire system 
Power   Consumption  Max.  1VA1W

 Cable parameters      
Cable entry / plug                         1 M20xl.5 cable entry (cable diameter   5 ~ 9mm)
1 blind blocking M20xl.5
Spring   terminals                            For wire   cross-section 2.5mm²



Output   parameters      
The output signal                             (4~20)mA / HART
Resolution                                   1.6μA
Fault   signal                                     Current output   unchanged;20.5mA;22mA;3.9mA
Two-wire load   resistor                    See below
Four-wire   resistive load                  The maximum 500Ω
Integration   time                                (0 ~ 36) s,   adjustable

latest guided wave radar level transmitter manufacturers for work-16


latest guided wave radar level transmitter manufacturers for work-17














 

 







Company Features
1. Guangdong Kaidi Energy Technology Co., Ltd. owns many production lines to meet customer's demands. We have a plant that is in compliance with internationally recognized standards of good manufacturing practices. It ensures that every product has the attributes of quality.
2. The comprehensive quality and ability level of our employees are high. They are well-educated about the domain-relevant know-how and profound and comprehensive understanding of our products. This advantage helps us better serve clients with targeted products.
3. Our engineers are among the best in the industry. They boast a broad range of skills and technical capabilities to solve challenges at any stage of the product lifecycle. We conduct business while aligning with the interests of individuals, companies, and society to strengthen the national economy and discourage fraud and mismanagement.
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...