loading
Kaidi Sensors | Level gauge & level indicator manufacturer
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 1
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 2
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 3
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 4
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 5
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 1
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 2
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 3
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 4
Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 5

Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy ±0.5% for liquids

5.0
Application:
liquids,powders,largesolidblocksandcorrosiveobjects
Protection Grade::
IP65
Accuracy::
±0.5%
Process Pressure::
525bar
Process Temperature::
-184 to 260°C
Explosion proof certification:
Non-explosion proof
Outer Covering::
2-wire loop power supply 4-20, 20-4mA measuring signal
MOQ:
1 SET
Payments:
TT, Paypal, Credit card, Western union
Shipping ways:
Express(DHL,Fedex,TNT,EMS,UPS)/Air/Sea
design customization

    oops...!

    no product data.

    Go to homepage
    PRODUCT INTRODUCTION


    The electronic circuit of YH2631 product adopts an anti-adhesion circuit, which can eliminate the influence of adhering and false level signals hanging around the probe while detecting the real level. It is an excellent level transmitter for measuring liquid, solid, interface and foam. It can work under extreme process conditions, and its temperature ranges from -184 to 260°C and pressure vacuum (FV) to 525 bar. It has excellent performance and a wide range of applications.

    WORKING PRINCIPLE


    The electronic circuit of YH2631 product adopts an anti-adhesion circuit, which can eliminate the influence of adhering and false level signals hanging around the probe while detecting the real level. It is an excellent level transmitter for measuring liquid, solid, interface and foam. It can work under extreme process conditions, and its temperature ranges from -184 to 260°C and pressure vacuum (FV) to 525 bar. It has excellent performance and a wide range of applications.


    FEATURES


     Patented effective shielding technology;

     

     Simple button adjustment;

     

     Frequency inversion technology provides higher resolution;

     

     2-wire loop power supply 4-20, 20-4mA measuring signal;

     

     High temperature and high pressure resistance;

     

     The product can detect any process materials, such as: refined oil, gasoline, conductive mud, etc.;

     

    This product is matched with LC86X type sensing probe. LC863 is a general-purpose probe, LC890 is a flat probe, and a steel rope probe is also available. It has a Teflon and stainless steel structure. It can be used in high temperature, high pressure environments, liquids, powders, large solid blocks and corrosive objects.


    Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 6

    TECHNICAL PARAMETER


     Power supply: 24VDC

     Maximum working current: MAX100mA

     420mA output impedance: MAX750Ω

     Delay time: 030" seconds continuously adjustable

    Accuracy: ±0.5%

     Material temperature: -184℃260℃

     RS485 communication port/high and low position/digital display: yes

     Adjustment method: button (digital adjustment)

     Thread size of outlet hole (waterproof connector for cable): M20*1.5 (diameter 812mm)

     Circuit temperature resistance: -40℃80℃

     Sensitivity: 0.5pf

     Power failure protection: high and low mode, adjustable on site

     Housing: IP65, heavy cast aluminum housing

    SELECTION TABLE


    ModelYH2631
    Connection method
    FFlange connection
    SThreaded connection
    Material
    4304SUS
    6316SUS
    L316LSUS
    TAnti-corrosion coating
    Probe length
    Customized by the user, the longest rod probe is 2.5m
    Customized by the user, the cable probe is up to 30m long
    Probe model
    LCP601Single probe
    LCW609Flexible single probe
    LCP607LCP607 Steel Shaft Probe
    LCP627Flange type double probe
    LCP628Flange type double probe
    LCW616Flexible dual probe (all Teflon)
    LCW615Flexible dual probe
    LCW613Flexible dual probe
    Explosion proof
    PNon-explosion proof
    IExplosion-proof type on-site display
    Live display
    YYES
    NNO


    PROBE MODEL


    LCP601: Single probe

    Used in metal containers, can detect most liquids, the probe is Teflon Coating, anti-corrosion. It is recommended to detect conductive liquids.

    Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 7

     LCW609: Flexible single probe

    The use occasions are the same as above. It is recommended to be used in applications with a length of more than 4 meters. If there is agitation, it is recommended to fix the bottom.


    Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 8


     LCP607: Steel shaft probe

    Detect low-viscosity liquids. Such as gasoline. (Recommended for mixing occasions)


    Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 9


     LCP627: Flange type double probe

    Applicable to various containers, and can detect non-corrosive liquids and powders to 316 stainless steel.


    Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 10


     LCP628: flange type double probe

    It is especially recommended for the detection of strong acids and bases. All contact surfaces are Teflon surfaces.


    Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 11


     LCW616: Flexible dual probe (all Teflon)

    It is recommended to detect strong acids and strong bases. Length greater than 3.5m 


    Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 12


    LCW615: Flexible dual probe

    It is recommended that the length exceeds 3.5m, which can be used to detect coal or cement.


    Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 13


    LCW613: Flexible dual probe

    Suitable for various occasions, it is recommended to detect pure water, industrial wastewater, etc. or pure water water-based solutions.


    Kaidi KD YH2631 RF Admittance Continuous Level Meter Accuracy  ±0.5% for  liquids 14

    Please Send Us your Application details

    Measuring range , medium, Installation method (flange, thread), Pressure range, Remote transmitter, Level alarm switch

    Our technical team will check your specifications and make a best solution for you.

    More Model available for all appication, different termperture and pressure!

    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs.
    Related Products

    CONTACT US

    Attn: Mr. Joe Zou
    Email:info86kd@gmail.com | info@kaidi86.com
    Tel: +86 756 8652289
    Fax: +86 756 8652290
    Mob: +86 18198790863 (whatsapp/Wechat Same Number)
    Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

    BETTER TOUCH BETTER BUSINESS

    Contact Sales at KAIDI level gauge manufacturer.

    Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
    Customer service
    detect