Abstract: Electromagnetic
flow meter cleaning method information is provided by excellent flow meter and flow meter manufacturers and quotation manufacturers. The routine detection of
electromagnetic flowmeter usually includes five aspects: electrode contact resistance, electrode polarization voltage, signal cable interference, determination of ground potential and pipeline stray current flow. The following Weinan and Shunda flowmeter manufacturers and technicians will make it simple for you. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the article on cleaning methods for electromagnetic flowmeters. The routine detection of electromagnetic flowmeter usually includes five aspects: electrode contact resistance, electrode polarization voltage, signal cable interference, determination of ground potential and pipeline stray current flow. The following flowmeter manufacturers and technicians will give you a brief introduction: the commonly used methods of electrode cleaning are as follows: 1. Electrochemical method: the metal electrode has electrochemical phenomena in the electrolyte fluid. According to the principle of electrochemistry, there is an interfacial electric field between the electrode and the fluid, and the interface between the electrode and the fluid is caused by the electric double layer existing between the electrode/fluid phase. The study of the electric field at the interface between the electrode and the fluid found that the molecules, atoms or ions of the substance have enriched or poor adsorption at the interface, and found that most inorganic anions are surface active substances with a typical ion adsorption law, while the surface of inorganic cations activity is small. Therefore, electrochemical cleaning of electrodes only considers the case of anion adsorption. The adsorption of anions is closely related to the electrode potential, and the adsorption mainly occurs in the potential range that is more positive than the zero-charge potential, that is, the electrode surface with the opposite sign. On the electrode surface of the same charge, when the residual charge density is slightly larger, the electrostatic repulsion is greater than the adsorption force, and the anions are quickly desorbed, which is the principle of electrochemical cleaning. 2. Mechanical removal method: The mechanical removal method realizes electrode removal by installing a special mechanical structure on the electrode. There are currently two forms: one is to use a mechanical scraper. A scraper with a thin shaft is made of stainless steel, and a mechanical seal is used between the thin shaft and the hollow electrode to prevent the outflow of the medium, so a mechanical scraper is formed. When the thin shaft is rotated from the outside, it is rotated against the flat surface of the electrode end to scrape off the dirt. This scraper can be used manually or automatically with a motor-driven thin shaft. 3. Ultrasonic cleaning method: The ultrasonic voltage of 45~65kHz generated by the ultrasonic generator is applied to the electrode, so that the energy of the ultrasonic wave is concentrated on the contact surface between the electrode and the medium, so as to use the ability of the ultrasonic wave to crush the dirt and achieve the purpose of cleaning. . 4. Electric breakdown method: This method uses alternating high-voltage electricity to be regularly added between the electrode and the medium, generally 30~100V. Because the electrode is attached, its surface contact resistance becomes larger, and the applied voltage is almost concentrated on the attached object. The high voltage will break down the attached object and then be washed away by the fluid. For overall safety, the use of electric breakdown method must be to clean the AC high voltage directly on the sensor signal output terminal when the flowmeter is interrupted for measurement, the signal line between the sensor and the converter is disconnected, and the power is cut off. an asymmetric common-mode voltage. The asymmetric common-mode voltage becomes a differential-mode signal, resulting in a zero offset. As a professional R&D flowmeter manufacturer, the flowmeter manufacturer has been adhering to the production concept of creating a brand with quality and seeking development with a brand for several years. We provide products with reliable quality and meet the needs. At the same time, we have established long-term cooperative relations with many production enterprises. All colleagues look forward to sailing with you. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Electromagnetic flow meter cleaning method broadcast'
level gauge customized level indicator, as the name suggests, find extensive use in customized level indicator institutions. Since customized level indicator has become much dependent on technology in today's world, there is wide use of such level gauge.
If you would like a great tip on where you can get level gauge customized level indicator for a great price, check out Kaidi level indicator. Guangdong Kaidi Energy Technology Co., Ltd. is committed to serving globally recognized . Quality is guaranteed here. Make your wise decision.
We focus on operational procedure and manufacturing facilities of level gauge.
Advanced technology and manufacturing equipment has enhanced the core quality of level gauge.