About common pressure transmitter fault types and solutions

Regarding the types of faults that occur in our common pressure transmitters and how to solve the problems, here I have compiled some common fault descriptions. I hope you can effectively and quickly encounter them in the future. Solved, let's analyze the situation together: (1) The pressure display value is abnormal. Abnormal pressure value display is a common fault of pressure transmitters. In addition to common zero drift and range migration problems, the causes include damage to components, sensor faults, line faults, electromagnetic interference, pressure tube/ Capillary problems, etc., need to be checked item by item. (2) Components are damaged. It is necessary to consider whether there is a short circuit or open circuit caused by lightning strike, excessive voltage, wrong wiring or cable damage. If it is verified that the electronic components are indeed burned or physically damaged, the damaged components or cables should be replaced in time, and the instrument grounding system should be checked for problems and repaired and maintained in time. It is necessary to pay attention to whether there is water entering the instrument and causing corrosion of the internal electronic components. When the cable interface is not tightly sealed and the sealing ring of the transmitter is aging, it is easy to cause water to accumulate in the meter, resulting in damage to the internal components. At this time, the damaged components should be replaced, and the sealing treatment and inspection of the transmitter should be done well. In a certain project, due to the limited space on site, the cable entry position of the transmitter is installed upwards, resulting in the accumulation of water in the transmitter, which should be taken as a warning. (3) Sensor failure. The diaphragm of the diaphragm pressure transmitter will condense on the diaphragm due to the crystallization of the medium, or the medium contains block solids that impact the diaphragm for a long time, causing the diaphragm to deform and damage and affect the measurement. At this time, the diaphragm should be replaced in time, and according to the actual working conditions, consider adding purging or adding a filter screen at the front end. (4) Line failure. Line faults are generally internal wiring, which can be checked by measuring resistance and voltage with a multimeter. Perform wiring operations according to the transmitter instructions to ensure the correct connection of the lines. (5) Electromagnetic interference. This kind of fault is generally more difficult to troubleshoot, but the frequency of occurrence is very high. The signal cable of the instrument should not be placed in parallel with the electrical high-voltage signal cable, otherwise it is easy to cause signal interference, resulting in communication errors and inaccurate measurement values. Be sure to follow the standard requirements for distance control and shielding measures. The transmitter installation should also avoid locations with strong magnetic/electric fields or strong vibration sources. (6) The problem of pressure tube and capillary tube. The pressure pipe problem usually occurs due to the characteristics of the medium, non-clean medium, or medium with high viscosity, causing the blockage of the pressure pipe and the inability to feedback accurate pressure values. Or the pressure tube may leak due to long-term use, resulting in measurement inaccuracy. If this happens, replace the pressure tube in time, and do regular cleaning and maintenance work. The capillary will have problems due to the inaccurate selection of the pressure oil temperature resistance. In low temperature conditions, it is necessary to select the appropriate pressure guiding oil to avoid the phenomenon that the pressure guiding oil solidifies due to the low temperature. Similarly, when it is necessary to pay attention to the high temperature, the pressure guiding oil should be avoided to vaporize. From this topic, a case is drawn: in a project, because the medium is steam, the method of connecting the condensing ring to the transmitter is adopted, but it is ignored that the ambient temperature will reach below -30 °C in winter, which results in that although the medium is steam , but in winter, the liquid in the condensation ring is still frozen into ice, which makes the pressure transmitter unable to sense pressure. Therefore, it is reminded that when selecting and designing the instrument, it is not only necessary to consider the medium conditions, but also the actual use environment. I hope the above can bring you a sufficient solution and solve the problem smoothly for you. You can log in to our Kaidi official website at any time to inquire about more

To live up to our responsibilities to serve and enhance the communities in which Guangdong Kaidi Energy Technology Co., Ltd. works and lives and the society on which we depend.

Finding the best products has been made easier, at Guangdong Kaidi Energy Technology Co., Ltd.. Here you can see completed ranges of produced with advanced equipment and strict quality control. Go to Kaidi level indicator and send your enquiry if you have any question.

Latest technology and manufacturing equipment has improved the quality of level gauge.

GET IN TOUCH WITH Us
recommended articles
INFO CENTER FAQ NEWS
Introduction:

Tank operations in various industries require a high level of precision, efficiency, and safety.
For industries that rely on large storage tanks to store liquids or gases, monitoring the levels and conditions of these tanks is vital for operational efficiency and safety.
Conveyor Belt Safety Switches: Ensuring Worker Safety

Conveyor belts are an essential part of many industries, from manufacturing to logistics.
Gas grills have become an essential part of many households, providing a convenient way to enjoy delicious meals in the comfort of your backyard.
Flow transmitters are essential components in various industries, providing accurate measurements of fluid flow rates.
Level Instrumentation: The Future of Measurement Technology

Level instrumentation plays a crucial role in various industries, providing accurate measurements of liquids, solids, and gases in tanks, silos, and pipelines.
Level Instruments: Essential for Process Optimization

Level instruments play a crucial role in ensuring the smooth operation and efficiency of industrial processes.
Radar Level Meters: How They Enhance Measurement Accuracy

Radar level meters are advanced devices used to accurately measure levels of liquids and solids in various industrial applications.
3D Radar Level Scanners: Applications in Mining

Mining operations require precise and accurate monitoring of the levels of materials such as ore, coal, and other resources stored in silos, bunkers, and stockpiles.
Ultrasonic Level Meters: Benefits in Chemical Processing

Ultrasonic level meters have revolutionized the way chemical processing plants monitor and control liquid levels in various tanks and vessels.

CONTACT US

Attn: Mr. Joe Zou
Email:info86kd@gmail.com | info@kaidi86.com
Tel: +86 756 8652289
Fax: +86 756 8652290
Mob: +86 18198790863 (whatsapp/Wechat Same Number)
Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

BETTER TOUCH BETTER BUSINESS

Contact Sales at KAIDI level gauge manufacturer.

Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
Customer service
detect