loading
Kaidi Sensors | Level gauge & level indicator manufacturer

What are the technical requirements for electromagnetic flow meter selection?

Abstract: What are the technical requirements for electromagnetic flow meter selection? The information is provided to you by the excellent manufacturers of flowmeters and flowmeters. According to the main types and performance of typical mainstream products of electromagnetic flowmeters, the selection has the following requirements: (1) The medium to be measured, measuring fluids Electromagnetic flowmeters can only measure conductive liquids, but cannot measure gases, oils and organic chemicals, etc. Non-conductive fluid. Usually electric. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. What are the technical requirements for electromagnetic flowmeter selection? Article details. According to the main types and performance of typical mainstream products of electromagnetic flowmeters, the selection has the following requirements: (1) The medium to be measured, measuring fluids Electromagnetic flowmeters can only measure conductive liquids, but cannot measure gases, oils and organic chemicals, etc. Non-conductive fluid. Usually the conductivity is 5µFor fluids above S/cm, general instruments can be selected. For conductivity 0.01µFor liquids above S/cm, and for slurry fluids containing solid particles and fibers, capacitive electromagnetic flowmeters can be used. (2) Products with nominal diameter DN (3'''-'3OOO) mm are available. (3) Excitation modes include rectangular wave excitation (two-way pulse, ternary wave, dual frequency), power frequency sine wave, and high frequency excitation mode. (4) The measurement range is converted to flow velocity: 0'''-'0.3m/s to 0'''-'12m/s are available. (5) Measurement accuracy The measurement error is±(0.2'''-'1)%FS, optional. (6) Structure The combination of the sensor and the converter is optional. (7) Wetted material: ①The lining is made of PTFE, rubber, polyurethane rubber, high-purity alumina, and ceramics. ② Electrodes include 316L stainless steel containing symplectic mesh, Hastelloy B, Hamin alloy C, aluminum, iron, conductive ceramics, uranium alloy, etc. ③Wetted parts 1Crl8Ni9Ti, 316L stainless steel with symplectic mesh, Hastelloy B, Hastelloy C, indium, iron, conductive ceramics, lead-based alloys, etc. Aluminum-bulk sintered type. (9) Medium temperature Fluoroplastic: one 10'''-'120°C (integrated type, split type 190°C). Rubber and Polyaminase: A 10'''-'60°C. High Purity Alumina:-10'''-'160°ce is related to ambient temperature and working pressure). (10) Connection methods: Flange connection, clamping type, quick connector, clamp type. (11) Power supply: AC: 85-----265yea.c.); There are two frequencies: 50Hz and 60Hz. DC: 16-----36V(d.c.)(12) Output signal: DC: 4r-....-20mA; Frequency: 0r-....-5kHz. (13) There are three types of installation forms: DN50 pipe column installation, wall installation and panel installation. (14) Select the flowmeter according to the application: ①Continuous immersion protection grade IP68: Water supply and drainage, sewage treatment installations are mostly in the wells of underground pipelines, rainwater and underground seepage often make the flowmeter immersed in water, or dew in winter, reducing The dielectric strength of terminals and coils affects product performance and shortens the service life of the flowmeter. ②Submersible type: It is used for open channel flow measurement, replacing the traditional Kanban flowmeter. ③Explosion-proof type: used in the environment with explosive gas, such as chemical industry, coal mine, oil field. ④Hygienic type: It is easy to disassemble, rinse and sterilize, and can be installed quickly. It is suitable for use in food and medicine departments. ⑤High pressure type: for drilling circulating mud in petrochemical industry, cementing mud, high pressure water injection in oil production process, etc. ⑥ General type: suitable for general purposes other than those mentioned above. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'What are the technical requirements for electromagnetic flow meter selection? 》

For the study, researchers defined KAIDI as strategies to foster some social good, including programs that benefit community engagement, diversity, the environment, human rights and employee relations.

Guangdong Kaidi Energy Technology Co., Ltd. intends to make enough profit to generate a fair return for our investors and to finance continued growth and development in level gauge.

There are multiple advantages of having a customized level indicator level gauge from responsible drilling machine exporters such as Guangdong Kaidi Energy Technology Co., Ltd., as they adhere to all the quality standards as you can list and supply all customized level indicator essential for the operation of the device without any difficulty.

GET IN TOUCH WITH Us
recommended articles
INFO CENTER FAQ NEWS
Introduction:

Tank operations in various industries require a high level of precision, efficiency, and safety.
For industries that rely on large storage tanks to store liquids or gases, monitoring the levels and conditions of these tanks is vital for operational efficiency and safety.
Conveyor Belt Safety Switches: Ensuring Worker Safety

Conveyor belts are an essential part of many industries, from manufacturing to logistics.
Gas grills have become an essential part of many households, providing a convenient way to enjoy delicious meals in the comfort of your backyard.
Flow transmitters are essential components in various industries, providing accurate measurements of fluid flow rates.
Level Instrumentation: The Future of Measurement Technology

Level instrumentation plays a crucial role in various industries, providing accurate measurements of liquids, solids, and gases in tanks, silos, and pipelines.
Level Instruments: Essential for Process Optimization

Level instruments play a crucial role in ensuring the smooth operation and efficiency of industrial processes.
Radar Level Meters: How They Enhance Measurement Accuracy

Radar level meters are advanced devices used to accurately measure levels of liquids and solids in various industrial applications.
3D Radar Level Scanners: Applications in Mining

Mining operations require precise and accurate monitoring of the levels of materials such as ore, coal, and other resources stored in silos, bunkers, and stockpiles.
Ultrasonic Level Meters: Benefits in Chemical Processing

Ultrasonic level meters have revolutionized the way chemical processing plants monitor and control liquid levels in various tanks and vessels.

CONTACT US

Attn: Mr. Joe Zou
Email:info86kd@gmail.com | info@kaidi86.com
Tel: +86 756 8652289
Fax: +86 756 8652290
Mob: +86 18198790863 (whatsapp/Wechat Same Number)
Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

BETTER TOUCH BETTER BUSINESS

Contact Sales at KAIDI level gauge manufacturer.

Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
Customer service
detect