Abstract: What are the solutions for the unstable zero point of electromagnetic
flowmeters? The information is provided by excellent flowmeter and flowmeter manufacturers and quotation manufacturers. Check the flow of the electromagnetic flowmeter for an unstable zero point. First, make a preliminary inspection and judgment according to the overall thinking of the process, and then carefully inspect and try to eliminate the faults one by one. The criteria for the order of inspection items listed in the process is that they can be understood by inspection or interrogation without major operations. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the solutions for the unstable zero point of the electromagnetic flowmeter. Check the flow of electromagnetic flowmeter zero point instability. First, make a preliminary inspection and judgment according to the overall thinking of the process, and then carefully inspect and try to eliminate the faults one by one. The order of inspection items listed in the process is the one that can be inspected or understood without major operations, that is, easy first and then difficult. According to the past on-site inspection experience, the one with higher frequency and higher probability may appear in the future. Check the sequential requests you need. If it is confirmed by preliminary inspection that it is the cause of the latter faults, a detailed inspection can also be made in advance. 1. The pipeline is not filled with liquid or the liquid contains air bubbles, which means that there is no activity in the flow sensor, but there is actually a small amount of activity. The main reasons for this type of failure are the poor airtightness of the shut-off valve of the pipeline, the small leakage detected by the electromagnetic flowmeter, and the misunderstanding of zero-point variation or zero-point instability. 2. It is often encountered that the valve has been used for a long time or the liquid is dirty so that the valve is not fully sealed, especially for large valves. Another common reason is that the flow meter has several branch pipes in addition to the main pipeline, and the valves of these branch pipes are forgotten or neglected to be closed. Sometimes, it is more difficult to confirm that there is no activity in the management system on the spot. At this point, you can press to see if there is any leakage. 3. The liquid conductivity varies or is uneven, the zero point will change when it is still, and the output will shake when it is active. Therefore, the position of the flowmeter should be far away from the injection point or the downstream of the chemical reaction section of the pipeline, and the flow sensor should be installed upstream of these places as much as possible. If the liquid contains solid phase, or impurities accumulate on the inner wall of the flow metering tube, or scale on the inner wall of the flow metering tube, or the electrode is contaminated by grease, etc., there may be a zero-point change. 4. Due to the fact that the scale on the inner wall and the outer surface of the electrode and the contamination level of the electrode cannot be completely the same and symmetrical, the equilibrium of the initial zero adjustment setting is destroyed. The active measure is to remove the dirt and the accumulation of scale layer; if the zero position does not change much, you can try to re-zero. 5. Changes in the state of the electrical equipment near the flow sensor (such as increased leakage current) result in changes in ground potential, which will also cause changes in the zero point of the electromagnetic flowmeter. The influence of external interference such as pipeline stray current mainly depends on the good grounding maintenance of the electromagnetic flowmeter. Generally, the grounding resistance is required to be less than 10, and the grounding should not be shared with other electrical appliances. Sometimes the environmental conditions are good, and the electromagnetic flowmeter can work normally without grounding, but once the good environment does not exist, the instrument will appear faulty, and it will bring a lot of trouble to check again at that time. 6. Check the flowchart. The insulation drop of the signal circuit will cause the zero point instability. The main reason for the insulation drop of the signal circuit is caused by the insulation drop of the electrode part, but the insulation drop or damage of the signal cable and its wiring terminals cannot be eliminated. Be careful, full of moisture acid mist or powder dust intrusion into the instrument junction box or cable protection layer, so that the insulation falls. 7. Check the insulation resistance of the signal loop and stop at the two parts of the cable side and the flow sensor respectively, and test with a megohmmeter. Since the signal cable is easy to detect, it can be done first. Liquid-filled electromagnetic flow measuring electrode surface contact resistance and empty pipe flow measuring electrode insulation resistance. Haines Automation Instrumentation is a professional manufacturer of electromagnetic flowmeters, turbine flowmeters, vortex flowmeters, magnetic flap
level gauges, thermocouples, thermal resistances, bimetal thermometers and pressure gauges of various specifications, etc., as well as the production of various As a manufacturer of non-standard flowmeters, the company has advanced management level, modern professional production equipment, and accurate calibration devices. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'What are the solutions for the instability of the zero point of the electromagnetic flow meter'
The increasing consumption demand in key segments such as customized level indicator, customized level indicator and customized level indicator have been driving the sales of and its derivatives worldwide.
Growing revenue is a common goal for many businesses. We want to be sure KAIDI include leaders from the marketing, sales and production departments to help make certain that the goals we choose are appropriate and have strong support.
To find a qualified at reasonable price, contact Guangdong Kaidi Energy Technology Co., Ltd. at Kaidi level indicator, a professional provider and tell them what you envision for your level gauge.
The risk of customized level indicator is reduced by customized level indicator with the consumption of .