Portable ultrasonic flow meter is suitable for on-line calibration and inspection measurement of liquid flow in various industrial sites. It has the characteristics of simple operation, high measurement accuracy, good consistency, on-line printing, long battery power supply and so on.
The ultrasonic wave carries information about the flow rate as it travels through a flowing fluid. Therefore, the flow rate of the fluid can be detected by receiving the ultrasonic wave, which is converted into flow. According to the detection methods, it can be divided into different types of ultrasonic flow meters, such as propagation velocity difference method, Doppler method, beam shift method, noise method and correlation method. Ultrasonic flow meter is a kind of flow meter which has been applied in recent years with the rapid development of integrated circuit technology
Non-contact instrument, suitable for measuring fluid and large pipe flow that is not easily accessible and observed. It can be linked with the water level meter to measure the flow of open water. The use of ultrasonic flow ratio does not need to install measuring elements in the fluid, so it will not change the flow state of the fluid, no additional resistance, the installation and maintenance of the instrument can not affect the operation of the production pipeline, so it is an ideal energy-saving flow meter.
Portable ultrasonic flow meter is suitable for on-line calibration and inspection measurement of liquid flow in various industrial sites. It has the characteristics of simple operation, high measurement accuracy, good consistency, on-line printing, long battery power supply and so on.
◓Measurement accuracy: better than 1%
◓Repeatability: better than 0.2%
◓Working power supply: 220VAC (standard), 110VAC (optional)
◓Measurement period: 500ms(2 times per second, 128 groups of data are collected per cycle)
◓Battery: built-in nickel metal hydride rechargeable battery can work continuously for 24 hours
◓Installation: external binding type installation
◓Display: 2*10 Chinese character backlight display (instantaneous flow, cumulative flow, signal status, etc.)
◓Signal output: isolated RS485
◓Communication protocol: MODBUS protocol, M-BUS protocol, FUJI extension protocol, and compatible with the communication protocol of similar products from other domestic manufacturers
◓Print output: built-in thermal integrated printer, real-time or timing printing
◓Data storage: optional built-in memory (SD card) can store time, instantaneous flow, cumulative flow, signal status, etc., and can import data into the computer (data storage and printing function can only choose one)
◓Heat function: optional PT100 external clip platinum resistor can realize heat measurement
◓Other functions: self-diagnosis, prompt the current working status is normal
◓Optional sensor: external clip type, plug plug type interface.
Ultrasonic flow meter is a device to measure the information of fluid velocity by detecting the effect of fluid flow on ultrasonic beam. According to the detection methods of signals, it can be divided into propagation velocity difference method, Doppler method, beam offset method, noise method and correlation method. Doppler method is to determine fluid flow by measuring ultrasonic Doppler frequency shift of scatterer in uneven fluid using acoustic Doppler principle. It is suitable for fluid flow measurement with suspended particles and bubbles. The beam migration method reflects the flow velocity by using the ultrasonic beam's propagation direction in the fluid as the flow velocity changes. At low flow velocity, the sensitivity is very low and the applicability is not great. At present is the most widely used is the "time difference method" measurement principle. Multi-pulse technology, digital information processing technology and signal processing circuit are combined to display the measured data in real time.
"Time difference method" is by sending the sensor to generate ultrasonic signal and send it out in the air flow, signal through the tube wall, fluid to the receiving sensor, at the same time, the receiving sensor diverges the same ultrasonic signal, signal through the tube wall, fluid to send the sensor. At this time, because the existence of the flow rate makes the time difference, the flow rate can be calculated according to the time difference, and then the flow rate.
Measurement accuracy | Better than 1% |
Repeatability | Better than 0.2% |
Power supply | 220VAC (standard), 110VAC (optional) |
Battery | Built-in nimH rechargeable battery can work continuously for 24 hours |
Installation | External binding type installation |
Display | 2*10 Chinese character backlight display (instantaneous flow, cumulative flow, signal status, etc.) |
Signal output | Isolated RS485 |
Communication protocol | MODBUS protocol, M-BUS protocol, FUJI extension protocol, and compatible with other domestic manufacturers of similar products of the communication protocol |
Printout | Built-in thermal integrated printer, real-time or timing printing |
Data storage | Optional built-in memory (SD card) can store time, instantaneous flow, cumulative flow, signal status, etc., and can import data into the computer (data storage or print function can only choose one) |
Heat function | Optional PT100 clamp platinum resistor can realize heat metering |
Other functions | Self-diagnosis, indicating whether the current working status is normal |
Optional sensor | External clip type, plug - in - pull type interface |
Measurement period | 500ms(2 times per second, 128 sets of data collected per cycle) |
Please Send Us your Application details
Measuring range , medium, Installation method (flange, thread), Pressure range, Remote transmitter, Level alarm switch
More Model available for all appication, different termperture and pressure!
We are here to help you! If you close the chatbox, you will automatically receive a response from us via email. Please be sure to leave your contact details so that we can better assist
Our technical team will check your specifications and make a best solution for you.