loading
Kaidi Sensors  >  AI - Page Sitemap  >  top vega radar level transmitter manual suppliers for work
top vega radar level transmitter manual suppliers for work

top vega radar level transmitter manual suppliers for work
  • top vega radar level transmitter manual suppliers for work
  • top vega radar level transmitter manual suppliers for work
  • top vega radar level transmitter manual suppliers for work
  • top vega radar level transmitter manual suppliers for work
  • top vega radar level transmitter manual suppliers for work
  • top vega radar level transmitter manual suppliers for work

top vega radar level transmitter manual suppliers for work

Our solid packing is suitable for long-distance transportation. Made of soft non-woven fabric, this product is extremely breathable
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

Application :

6GHz radar level gauge is suitable for liquid, paste, granule and block material level and non-contact measurement, suitable for changes in temperature, pressure big; there is an inert gas and volatile.

The measurement method of microwave pulse, can work normally in the industrial frequency band range. The beam energy is low, can be installed on all kinds of metal, non-metallic container or pipe, no harm to human body and environment


Suitable   for Medium:Liquid,   slightly corrosive liquid
Explosion-proof   Grade: Exia IIC T6 Ga/ Exd   IIC T6 Gb 
Measuring   Range: 20m 
Aerials: The Rod Antenna  ( PP /PTFE ) 
Frequency: 6 GHz
Temperature: (-40 ~ 130)
Measurement   Precision:  ±10mm 
Process   Pressure: (-0.1 ~ 0.3) Mpa
The signal   Output: (4 ~ 20) mA/HART 
The Scene   Display: Four LCD /Can be   programmed
Power   Source: Two-wire (DC24V) Four-wire (DC24V/AC220V) 
Repeatability: ± 1mm 
Outer   Covering : Aluminum /Plastic /   Stainless steel
Connection: Flange (optional) /   Thread


top vega radar level transmitter manual suppliers for work-1



top vega radar level transmitter manual suppliers for work-2

1.   Dimensions  of  Instruments

top vega radar level transmitter manual suppliers for work-3

 

2. The  Electrical  Connection

l  The power supply voltage: 

(4~20)mA/HART (Two wire system)       The power supply and   the output current signal sharing a two core shield cable. The supply voltage   range see technical data. For intrinsically safe type must be a safety   barrier between the power supply and the instrument.
(4~20)mA/HART(Four   wire system)      Separate   power supply and the current signal, respectively using a two-core shielded   cable. The supply voltage range see technical data.
RS485   / Modbus                                      Power supply and Modbus signal line are   separated, respectively using a two-core shielded cable, the power supply   voltage range see technical data.

top vega radar level transmitter manual suppliers for work-4

 l  Explosion Proof Connection

The intrinsic safety version sensors (Exia IIc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia IIc T6.

A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: Exia IIC, voltage of power supply: 24V DC±5%, short-circuit current: 135mA, operating current: 4...20mA.

All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor0.1μF/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used.

 top vega radar level transmitter manual suppliers for work-5


3.  Protection Grade :

 This instrument meets the protection class IP66/67 requirements, please ensure the waterproof cable sealing head. The following diagram:

 top vega radar level transmitter manual suppliers for work-6

 How to install to meet the requirements of IP67:

Please make sure that the sealing head is not damaged.

Please make sure that the cable is not damaged.

Please make sure that the cable for use with electrical connection specification.

Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the

Tighten the cable seal head, see the

Please electrical interface will not use blind plug tight, see the

 

4.  Technival Parameters:

1) General   data    
The outer shell /   Materials 
Antenna                                               PTFE, PP
Outer   Covering                                   Aluminum, Plastic,   Anti-static PP, Stainless steel 316
The seal   housing and the housing       Silicone Rubber 
Shell   window                                       Polycarbonate
Ground   terminal                                   Stainless steel
Process   connection  
801G1½A Thread & 1½NPT Thread / Flange (optional) 
802With PTFE plate   flange
Supply voltage  
Two-wire        
Standard                                       (1626)V DC
Intrinsically   Safe                           (21.626.4)V DC
Power   Consumption                      Max.22.5mA 
Allowable   ripple 
<100HzH47Uss < lV
- (100100K)Hz   Uss < l0mV
Flameproof
(22.8 ~ 26.4)   V DC       2-wire system
(198 ~242)V   AC   4-wire system / 110V AC    4-wire system 
Power   Consumption  Max.  1VA1W
2) Cable parameters      
Cable entry / plug                         1 M20xl.5 cable entry (cable diameter   5 ~ 9mm)
1 blind blocking M20xl.5
Spring   terminals                            For wire   cross-section 2.5mm²


3) Output   parameters      
The output signal                             (4~20)mA / HART
Resolution                                   1.6μA
Fault   signal                                     Current output   unchanged;20.5mA;22mA;3.9mA
Two-wire load   resistor                    See below
Four-wire   resistive load                  The maximum 500Ω
Integration   time                                (0 ~ 36) s,   adjustable

top vega radar level transmitter manual suppliers for work-7



vega radar level transmitter manual's structure is more compact and easy to be installed, so as to effectively reduce labor intensity and shorten operating time. This product is lightweight, which is easy to carry for travel
Guangdong Kaidi Energy Technology Co., Ltd. mainly assemble vega radar level transmitter manual whose materials including vega radar level transmitter manual. This product allows for a quick change
vega radar level transmitter manual is a new type of vega radar level transmitter manual made of advanced materials. This product is characterized by its leakproof property
vega radar level transmitter manual can not be competitive without the changing design of vega radar level transmitter manual. Its velcro design makes it easy to adjust
The results show that vega radar level transmitter manual with vega radar level transmitter manual material presents excellent performance. This product is able to keep the skin dry and healthy
vega radar level transmitter manual are the characteristics of vega radar level transmitter manual. The product has been certified under CE, SGS, and FDA
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...