loading

Selection of installation classification structure of electromagnetic flow meter

by:Kaidi Sensors     2022-07-27
Abstract: The information on the installation, classification and structure selection of electromagnetic flowmeters is provided by excellent flowmeter and flowmeter manufacturers and quotation manufacturers. Installation of electromagnetic flowmeter The correct installation of electromagnetic flowmeter is extremely important to the normal operation of electromagnetic flowmeter. The installation of electromagnetic flowmeter and converter is mainly introduced here. 1. Electromagnetic flowmeter sensor installation Electromagnetic flowmeter sensor installation should pay attention to. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the installation, classification and structure selection of electromagnetic flowmeters. Installation of electromagnetic flowmeter The correct installation of electromagnetic flowmeter is extremely important to the normal operation of electromagnetic flowmeter. The installation of electromagnetic flowmeter and converter is mainly introduced here. 1. Electromagnetic flowmeter sensor installation Electromagnetic flowmeter sensor installation should pay attention to the following issues: (1) The shell protection level of the ordinary electromagnetic flow sensor in the installation site is IP65 (dust and splash-proof water level specified by GB4208), and the requirements for the installation site are : 1) When measuring mixed-phase fluid, choose a place that will not cause phase separation; 2) Choose a place where negative pressure will not appear in the measuring tube; 3) Avoid installing near strong electrical equipment such as motors and transformers to avoid electromagnetic field interference ; 4) Avoid installing in places with strong corrosive gases around; 5) The ambient temperature should generally be in the range of -25~60 °C, and avoid direct sunlight as much as possible; 6) Install in places without vibration or small vibration. If the vibration is too large, a fixed support should be added to the pipeline before and after the sensor. 7) The relative humidity of the environment should generally be in the range of 10%~90%; 8) Avoid installing in places that can be directly drenched by rain or submerged by water. The last two items are not required if the enclosure protection level of the sensor is IP67 (dust-proof and water-proof) or IP68 (dust-proof and submersible). (2) The length of the straight pipe section The electromagnetic flowmeter has relatively low requirements on the length of the straight pipe section in front of the meter. Generally, for 90°Flow resistance parts such as elbows, T-shaped tee, reducers, and fully open valves should have a straight pipe length of 3-5D from the centerline of the sensor electrode axis (not the sensor inlet end face); for valves with different openings, the A straight pipe length of 10D is required; generally, there should be a 2D straight pipe length behind the sensor. When the valve cannot be fully opened, if the valve shut-off direction is 45° from the sensor electrode axis°Installation can greatly reduce the additional error. (3) Installation position and flow direction The electromagnetic flow sensor can be installed horizontally, vertically or obliquely. When installed horizontally, the sensor electrode shaft must be placed horizontally. This prevents short-term insulation of the electrodes due to air bubbles entrained in the fluid; it also prevents the electrodes from being covered by deposits in the fluid. The sensor should not be installed at the highest point to avoid gas accumulation. It should be avoided if it is installed at the highest point of the piping system, which is a bad installation position. When installed vertically, the flow direction should be upward, so that when there is no flow or very little flow, the heavier solid particles entrained in the fluid sink, while the lighter fatty substances rise away from the sensor electrode area. When measuring liquid-solid two-phase flow such as mud and ore slurry, vertical installation can avoid solid phase precipitation and uneven wear of sensor lining. At the outlet of a down pipe, it is a poor installation position and should be avoided. The sensor installation place should have a certain back pressure, and the direct emptying of the sensor outlet will easily cause the liquid in the measuring tube to be not full, which is a bad installation position and should be avoided. To prevent negative pressure in the sensor, the sensor should be installed behind the pump, not in front of the pump. (4) Installation of bypass pipe In order to facilitate the inspection and adjustment of the zero point when the liquid flow is static, the bypass pipe should be installed as much as possible for small and medium pipe diameters. When measuring fluids containing sediment, consideration should be given to mounting the sensor for easy cleaning. (5) Grounding In order to make the measurement accurate and the electrode will not corrode, the electromagnetic flow sensor must be grounded separately, and the sensor and the fluid should be approximately at the same potential. In principle, the grounding of the separate electromagnetic flowmeter should be on the sensor side, and the grounding of the converter should be at the same grounding point. In most cases, the built-in reference electrode or metal tube of the sensor can ensure the allowable potential balance.
level gauge has become a standardized way of dealing with customized level indicator.
Make your customized level indicator customized level indicator. Invest in professional level gauge services. For more info, check out Kaidi level indicator.
Guangdong Kaidi Energy Technology Co., Ltd. will do this by managing our business with integrity and the highest ethical standards, while acting in a socially responsible manner with particular emphasis on the well-being of our teammates and the communities we serve.
Guangdong Kaidi Energy Technology Co., Ltd., which contributes itself on level gauge for creating more useful application.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...