loading
Kaidi Sensors  >  AI - Page Sitemap  >  Kaidi Sensors latest radar water level sensor suppliers for work
Kaidi Sensors latest radar water level sensor suppliers for work

Kaidi Sensors latest radar water level sensor suppliers for work
  • Kaidi Sensors latest radar water level sensor suppliers for work
  • Kaidi Sensors latest radar water level sensor suppliers for work
  • Kaidi Sensors latest radar water level sensor suppliers for work
  • Kaidi Sensors latest radar water level sensor suppliers for work
  • Kaidi Sensors latest radar water level sensor suppliers for work
  • Kaidi Sensors latest radar water level sensor suppliers for work

Kaidi Sensors latest radar water level sensor suppliers for work

Kaidi Sensors radar water level sensor is well manufactured. Every process such as chip producing, bulb manufacturing, and lampshade surface treatment are paid close attention. Its integrated body offers easy installation, thus, it helps to save much time
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

Application :

6GHz radar level gauge is suitable for liquid, paste, granule and block material level and non-contact measurement, suitable for changes in temperature, pressure big; there is an inert gas and volatile.

The measurement method of microwave pulse, can work normally in the industrial frequency band range. The beam energy is low, can be installed on all kinds of metal, non-metallic container or pipe, no harm to human body and environment


Suitable   for Medium:Liquid,   slightly corrosive liquid
Explosion-proof   Grade: Exia IIC T6 Ga/ Exd   IIC T6 Gb 
Measuring   Range: 20m 
Aerials: The Rod Antenna  ( PP /PTFE ) 
Frequency: 6 GHz
Temperature: (-40 ~ 130)
Measurement   Precision:  ±10mm 
Process   Pressure: (-0.1 ~ 0.3) Mpa
The signal   Output: (4 ~ 20) mA/HART 
The Scene   Display: Four LCD /Can be   programmed
Power   Source: Two-wire (DC24V) Four-wire (DC24V/AC220V) 
Repeatability: ± 1mm 
Outer   Covering : Aluminum /Plastic /   Stainless steel
Connection: Flange (optional) /   Thread


Kaidi Sensors latest radar water level sensor suppliers for work-1



Kaidi Sensors latest radar water level sensor suppliers for work-2

1.   Dimensions  of  Instruments

Kaidi Sensors latest radar water level sensor suppliers for work-3

 

2. The  Electrical  Connection

l  The power supply voltage: 

(4~20)mA/HART (Two wire system)       The power supply and   the output current signal sharing a two core shield cable. The supply voltage   range see technical data. For intrinsically safe type must be a safety   barrier between the power supply and the instrument.
(4~20)mA/HART(Four   wire system)      Separate   power supply and the current signal, respectively using a two-core shielded   cable. The supply voltage range see technical data.
RS485   / Modbus                                      Power supply and Modbus signal line are   separated, respectively using a two-core shielded cable, the power supply   voltage range see technical data.

Kaidi Sensors latest radar water level sensor suppliers for work-4

 l  Explosion Proof Connection

The intrinsic safety version sensors (Exia IIc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia IIc T6.

A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: Exia IIC, voltage of power supply: 24V DC±5%, short-circuit current: 135mA, operating current: 4...20mA.

All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor0.1μF/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used.

 Kaidi Sensors latest radar water level sensor suppliers for work-5


3.  Protection Grade :

 This instrument meets the protection class IP66/67 requirements, please ensure the waterproof cable sealing head. The following diagram:

 Kaidi Sensors latest radar water level sensor suppliers for work-6

 How to install to meet the requirements of IP67:

Please make sure that the sealing head is not damaged.

Please make sure that the cable is not damaged.

Please make sure that the cable for use with electrical connection specification.

Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the

Tighten the cable seal head, see the

Please electrical interface will not use blind plug tight, see the

 

4.  Technival Parameters:

1) General   data    
The outer shell /   Materials 
Antenna                                               PTFE, PP
Outer   Covering                                   Aluminum, Plastic,   Anti-static PP, Stainless steel 316
The seal   housing and the housing       Silicone Rubber 
Shell   window                                       Polycarbonate
Ground   terminal                                   Stainless steel
Process   connection  
801G1½A Thread & 1½NPT Thread / Flange (optional) 
802With PTFE plate   flange
Supply voltage  
Two-wire        
Standard                                       (1626)V DC
Intrinsically   Safe                           (21.626.4)V DC
Power   Consumption                      Max.22.5mA 
Allowable   ripple 
<100HzH47Uss < lV
- (100100K)Hz   Uss < l0mV
Flameproof
(22.8 ~ 26.4)   V DC       2-wire system
(198 ~242)V   AC   4-wire system / 110V AC    4-wire system 
Power   Consumption  Max.  1VA1W
2) Cable parameters      
Cable entry / plug                         1 M20xl.5 cable entry (cable diameter   5 ~ 9mm)
1 blind blocking M20xl.5
Spring   terminals                            For wire   cross-section 2.5mm²


3) Output   parameters      
The output signal                             (4~20)mA / HART
Resolution                                   1.6μA
Fault   signal                                     Current output   unchanged;20.5mA;22mA;3.9mA
Two-wire load   resistor                    See below
Four-wire   resistive load                  The maximum 500Ω
Integration   time                                (0 ~ 36) s,   adjustable

Kaidi Sensors latest radar water level sensor suppliers for work-7



The lampshade of Kaidi Sensors radar water level sensor has undergone several fabrication processes, including CNC machining, metal forming, welding, spray painting and drying, and stamping. It has been exported to Europe, America, Southeast Asia, and Africa
Kaidi Sensors radar water level sensor has passed various kinds of tests according to international lighting standards. In some cases, some even tougher standards such as vibration test are adopted to make sure that it is going to last. Treated by die-casting, Its structure is robust and firm
To guarantee the luminous efficiency of Kaidi Sensors radar water level sensor, its materials have undergone rigorous screening and only those that meet international lighting standards are selected. Its battery features fast charging and low discharge time
Kaidi Sensors [拓展关键词 is superior in raw materials. Inferior materials are totally rejected into the factory, which ensures the luminous efficiency. The product is certified under CE, ROHS, FCC, EMC, and LVD
Kaidi Sensors radar water level sensor strictly undergoes a series of compatible testing. For example, its color rendering, light uniformity, and brightness are checked carefully. Its anti-oxidation body guarantees its durability
Our radar water level sensor is able to undergo the strict tests thanks to radar water level sensor. Containing imported LED chips, this product has high CRI
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...