Kaidi Sensors  >  AI - Page Sitemap  >  Kaidi Sensors electromagnetic flow transducer for business for industrial
Kaidi Sensors electromagnetic flow transducer for business for industrial

Kaidi Sensors electromagnetic flow transducer for business for industrial
  • Kaidi Sensors electromagnetic flow transducer for business for industrial

Kaidi Sensors electromagnetic flow transducer for business for industrial

Brief IntroductionKFL-DG series electromagnetic flowmeters follow the...
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:
Company Advantages
1. The innovative design enrichs the overall look of Kaidi Sensors . This product features very low no-load losses
2. Whether it is R&D, production, quality control, business marketing or technical services, Kaidi Sensors insists on providing the best. This product has the ability to accurately convert a physical parameter into a signal
3. It is indicated that electromagnetic flow transducer has many advantages such as , and the practical application of is promoted effectively.
4. can be seen in this electromagnetic flow transducer which can . It is able to quickly and effectively detect and respond to some types of input
5. The leading features of electromagnetic flow transducer include and long service life. This product is not susceptible to cracks

Brief Introduction

KFL-DG series electromagnetic flowmeters follow the Faraday law of electromagnetic induction. They can be used to accurately measure the flow rate of liquids which are electrical conducting, caustic, and mixed with liquids and solids. They are widely used throughout industries of petroleum, chemical engineering, pharmacology, papermaking, electric power, environmental protection and so forth. Their antiknock level is ExdIIBT4.the feature of Kaflon High Quality& Accuracy Low Cost Electromagnetic Flow meter is 1- zero pressure losing; 2- High accuracy, Stable performance, high level of anti-vibration and anti-jamming, wide measuring dimensions. 3- Corrosion protection, abrasion resistant;4.life long time.

Features

1)No Moving Parts, Virtually No Pressure Loss;

2)Corrosion protection, abrasion resistant;

3)High accuracy, Stable performance;

4)High level of anti-vibration and anti-jamming, wide measuring dimensions.

5)Multi-Output Interface4~20mA, Pulse, Alarm Outputs, RS-485 and Modbus Communication

Operating Principle

Faradays Laws of Induction form the basis for the electromagnetic flowmeters. It states that a voltage is induced in a conductor as it moves through a magnetic field.

This principle is applied to a conductive fluid which flows through a magnetic field generated perpendicular to the flow direction (see Schematic).

The voltage induced in the fluid is measured at two electrodes, installed diametrically opposed. This signal voltage UE is proportional to the magnetic induction B, the electrode spacing D and the average flow velocity v. Noting that the magnetic induction B and the electrode spacing D are constants, a proportionality exists between the signal voltage UE and the average flow velocity v. The equation for the volume flow shows that the signal voltage UE is linear and proportional to the volume flowrate. The induced signal voltage is processed in the converter into scaled, analog and digital signals.

Specifications

- Size: DN10~DN600 (PTFE) ; DN40~DN1200 (NBR)

- Standard pressure: PN1.0MPa~40MPa;

- Accuracy: ±0.5%~±1.0%;

- Supply power: 85 to 250VAC (45 to 63Hz), 16 to 36VDC;

- Signal output: Current Output: 4~20mA;

- Frequency Output: 0~5000Hz with photoelectric isolation;

- Pulse Output: 0.001~1.000m3/cp, 0.001~1.000 Ltr/cp, 0.001~1.000USG/cp,0.001~1.000 UKG/cp;

- Alarm Output: Upper Alarm-ALMH, Lower Alarm-ALML with photoelectric isolation;

- Communications: RS-232 without galvanic isolation, RS-485 with Galvanic isolation;

- Ambient temperature: -10~60;

- Relative humidity: ≤85%RH;

- Atmospheric pressure: 86KPa~106KPa;

- Applicable Fluid: electrically conducting liquid;

- Fluid temperature:-25~ +65 and -25~ +180;

- Electrical conductivity: 5us/cm.



Company Features
1. Guangdong Kaidi Energy Technology Co., Ltd. is committed to the development, manufacture, sales and service of electromagnetic flow transducer . Except providing the best insertion electromagnetic flow meter , we also offer you the competitive price.
2. Guangdong Kaidi Energy Technology Co., Ltd. owns a large scale production base to ensure the bulk production.
3. Our technology ability is recognized not only by our global customers but also by authoritative institutions. We worked with customers, suppliers, and business partners to identify the sustainability areas that offer the greatest opportunity to deliver business value, those that help increase resiliency across our value chains.
Removal of the edge, or flash, from a Kaidi Sensors insertion electromagnetic flow meter can be accomplished in a number of ways including manual tear trimming, cryogenic processing, tumbling precision grinding. This product can repeat the same measurement many times
Kaidi Sensors electromagnetic flow transducer has achieved quality management system certification in accordance with both domestic and international standards in regards to porcelain manufacture. This product is notable for its strong overload capacity
During the designing stage of Kaidi Sensors electromagnetic flow transducer, sketches and CAD technique are used by the designers who strive to create a product with the function of foot orthopedic. There is little variation between its measuring values
Kaidi Sensors [拓展关键词 is superior in raw materials. Inferior materials are totally rejected into the factory, which ensures the luminous efficiency. This product has a high level of IP
In the manufacture of Kaidi Sensors insertion electromagnetic flow meter, a range of techniques have been used, from CAD design, 3D imaging, model manufacturing, to final assembly. With a simple structure, it is perfectly good for demanding industrial applications
Long service life absolutely manifests its superior performance. This product features very low no-load losses
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...