loading
Kaidi Sensors  >  AI - Page Sitemap  >  KAIDI radar level sensors manufacturers for industrial
KAIDI radar level sensors manufacturers for industrial

KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial
  • KAIDI radar level sensors manufacturers for industrial

KAIDI radar level sensors manufacturers for industrial

PRODUCT OVERVIEW
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

PRODUCT OVERVIEW

As a result of advanced microprocessor and unique choDiscovery echo processing technology, guided wave radar level meter can be used in a variety of complex conditions.

Because of the type of process connections and detection components, making 70X Series Guided Wave Radar Level Meter is suitable for a variety of complex conditions and applications. Such as: high temperature, high pressure and low dielectric constant media.

Pulsed work, guided wave radar level instruments transmit power is very low, can be installed in a variety of metals, non-metallic container, no harm to humans and the environment.


KAIDI radar level sensors manufacturers for industrial-1


THE PRODUCT PRINCIPLE

High-frequency microwave pulses issued by the guided wave radar propagate along detection components (steel cable or steel rod), met the media to be measured, since the dielectric constant of the mutation, cause reflections, a portion of the pulse energy is reflected back. Transmit pulse and the reflected pulse is proportional to the distance and the time interval measured media.

KAIDI radar level sensors manufacturers for industrial-2


Note: In order to ensure the accuracy of level measurement, the material should be located between the top and bottom of the blind the blind.

PROTECTION GFEATURES

KAIDI radar level sensors manufacturers for industrial-3

Ø Small antenna size, easy to install; Non-contact radar, no wear, no pollution.

Ø Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure

changes.

Ø Serious dust environment on the high level meter work has little effect.

Ø A shorter wavelength, the reflection of solid surface inclination is better.

Ø Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.

Ø The measuring range is smaller, for a measurement will yield good results.

Ø High signal-to-noise ratio, the level fluctuation state can obtain better performance.

Ø High frequency, measurement of solid and low dielectric constant of the best choice.


PRODUCT SPECIFICATION


KAIDI radar level sensors manufacturers for industrial-4

APPEARANCE OF SIZE


KAIDI radar level sensors manufacturers for industrial-5


TECHNICAL PARAMETERS

KAIDI radar level sensors manufacturers for industrial-6

KAIDI radar level sensors manufacturers for industrial-7



KAIDI radar level sensors manufacturers for industrial-8

 









KAIDI radar level sensors manufacturers for industrial-9

KAIDI radar level sensors manufacturers for industrial-10


KAIDI radar level sensors manufacturers for industrial-11


INSTALLATION REQUIREMENTS

Within the measurement range, determined not to come into contact with the cable or rod internal obstacles, Therefore, the installation should be avoided as far as possible the tank facilities, such as: human ladder, limit switches, heating devices, stand etc. Also note that the cable or rod may not intersect with the material during feeding.

Also note that when installing the meter:Highest Level measurement can not enter into the blind; Must be maintained between the instrument and the tank wall a certain distance; When the meter is installed, try to stick with cable or perpendicular to the surface of the measured medium. Meter installation in hazardous areas must comply with state regulations explosion hazardous installation area. Intrinsically safe instrument requires the use of shell with aluminum. Intrinsically safe instrument can be installed in explosion-proof requirements of the occasion, the instrument must be connected to the earth.


KAIDI radar level sensors manufacturers for industrial-12


 The following guidelines apply to the installation of the cable and the rod radar level measuring solid powder or liquid.

 KAIDI radar level sensors manufacturers for industrial-13

KAIDI radar level sensors manufacturers for industrial-14

KAIDI radar level sensors manufacturers for industrial-15




Kaidi Sensors radar level sensors meets the requirements of some necessary certifications. They include CCA Certification, CB Certification, IEC International Safety Standards, etc.
The manufacturing processes of Kaidi Sensors radar level sensors cover several stages. They may include the fabrication and solder of the circuit board, surface treatment, insulation testing, assembly, and commissioning.
The manufacturing of Kaidi Sensors radar level sensors is sophisticated and requires much workmanship. The processes mainly include: raw materials inspection, sizing formula, ball milling, glaze treating, and sintering.
Kaidi Sensors radar level sensors will be carefully packaged before shipping. It will be inserted by hand or by automated machinery into protective plastic or paper covers. Additional information about the warranty, safety, and care of the product is also included in the packaging.
The design of Kaidi Sensors radar level sensors adopts various technologies. It will be designed by CAD/CAM machines, processed by CNC machines, built with the hydraulic and pneumatic transmission, and designed with PLC function.
The product has fine physical properties which are determined by the composition and the strength of the chemical bonds in its ordered internal structure.
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...