1.Product Introduction
The company independently designed and developed a special magnetic liquid level gauge for gasification prevention for liquid gas, liquid ammonia, propylene, propane and other easily gasified measuring media. The main cavity of the liquid level gauge is designed with a bubble elimination mechanism, which is effective It eliminates the false liquid level display caused by the floating ball jumping up and down caused by bubbles, and can ensure that the normal up and down movement of the floating ball is not affected.
2.Technical Parameter
3.Selection table
Model | illustrate | |||
UZ | Subpeak Magnetic Level Gauge | |||
Type of installation | C | Side loading | D | Top loading |
Panel type | A1 | -40-80℃ normal temperature | Z1 | -190~-20℃ Vacuum |
A2 | 80-180℃ medium temperature | Z2 | -20-180℃ Vacuum | |
A3 | 180-350℃ high temperature | Z3 | Vacuum at 180-350℃ | |
A4 | 350-450℃ ultra high temperature | E | -40℃-450℃ magnetic sensitivity | |
Pressure Rating (MPa) | 1 | PN1.0 | 2 | CL150LB |
1.6 | PN1.6 | 5 | CL300LB | |
2.5 | PN2.5 | 11 | CL600LB | |
4 | PN4.0 | 15 | CL900LB | |
6.3 | PN6.3 | 26 | CL1500LB | |
10 | PN10.0 | 42 | CL2500LB | |
16 | PN16.0 | |||
Range-Density | Range mm-density g/cm³ | |||
Flange Material | P | 304 | PF | 304 lined with fluorine |
PL | 316L | C | Carbon steel | |
PP | PP | Ti | titanium | |
Flange Diameter | 15 | Side mounted DN15 | 50 | Top loading DN50 |
20 | Side mounted DN20 | 65 | Top loading DN65 | |
25 | Side mounted DN25 | 80 | Top loading DN80 | |
32 | Side mounted DN32 | 100 | Top loading DN100 | |
40 | Side mounted DN40 | 125 | Top loading DN125 | |
50 | Side mounted DN50 | 150 | Top loading DN150 | |
65 | Side mounted DN65 | 200 | Top loading DN200 | |
80 | Side mounted DN80 | 250 | Top loading DN250 | |
Flange sealing surface | Omit | Raised face | FM | Concave |
F | Convex | FF | Full plane | |
Tube material | P | 304 | P1 | 321 |
PL | 316L | P4 | 304L | |
PF | 304 lined with fluorine | Ti | titanium | |
PP | PP | |||
Insulation/anti-frost | Omit | No | ||
C | Type C insulation pipe (recommended) | |||
T1 | Set vacuum insulation | |||
T2 | Jacket insulation | |||
D1 | 40-90 constant temperature electric heating | |||
D2 | 120°C temperature control adjustable electric heating | |||
S1 | Anti-frost below -40°C | |||
S2 | -40~-20℃ anti-frost | |||
Accessories | Y | Remote transmission level gauge | ||
K | Alarm switch |
4.Dimensions
We are here to help you! If you close the chatbox, you will automatically receive a response from us via email. Please be sure to leave your contact details so that we can better assist