Kaidi Sensors  >  AI - Page Sitemap  >  KAIDI best belt tear switch for business for transportation
KAIDI best belt tear switch for business for transportation

KAIDI best belt tear switch for business for transportation
  • KAIDI best belt tear switch for business for transportation

KAIDI best belt tear switch for business for transportation

Tasks that are too heavy or too delicate for human muscles to do can be done easily by this product. This product has a high level of IP
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:
Company Advantages
1. Relevant tests will be conducted once the KAIDI is produced. It will be tested on the dyeing quality and workmanship to meet the mandatory standard: Basic technical specifications for safety of textiles. With a simple structure, it is perfectly good for demanding industrial applications
2. Tasks that are too heavy or too delicate for human muscles to do can be done easily by this product. This product has a high level of IP
3. This product has outstanding characteristics of corrosion resistance and wear resistance, which can effectively reduce the wear rate of the ophthalmic lens. It works stably under strong impact and vibration conditions
4. This product is safe to use. It uses the appropriate safety devices, including emergency stop buttons and protective covers. This product can repeat the same measurement many times
5. This product is not affected by disinfectants. The metal materials used have been specially coated, which makes it stand up being cleaned under disinfection environments. This product is not susceptible to cracks


Product Description

High-quality stainless steel casting, high strength, never rust, IP67 protection rating, and good sealing. Pull Cord Switch is an emergency switch to stop the belt conveyor instantly when an accident happens. Since the Pull Cord Switch is so designed that it should be installed at the side of belt conveyor and the pull cord should be mounted along conveyor, the switch can be actuated at any position. Weatherproof type: IP67. The internal contact is the high performance micro switch from Japan, with high contact capacity. It can directly control high capacity contactor, with 2 normally open and 2 normally closed output. Additionally, we also produce pull cord switch with the internal contact close to the sensor .

 

WIRING DIAGRAM


KAIDI best belt tear switch for business for transportation-1

 

Drawings

 

a. Auto-reset

KAIDI best belt tear switch for business for transportation-2

 

   b. Manual reset


KAIDI best belt tear switch for business for transportation-3

 

ENVIRONMENTAL CONDITIONS

The Pull Cord Switch should be used in the following environmental conditions; especially made products should be used at the allowable conditions noted in the approved drawing or the final drawing.

l  Temperature 10°C~+50°C

Do not use the Pull Cord Switch in the place where there is danger of freezing.

l  Humidity less than 80%

l  Dust

If much dust adheres to the touch roller and it solidifies the Pull Cord Switch will not move normally.

To prevent dust from adhering to the touch roller, it should be cleaned at regular intervals.

l  Explosive and Corrosive Environment

The standard Pull Cord Switch should never be use under these conditions.

INSTALLATION

Fitting bolts

The fitting bolts should be prepared before installation, and should be fitted into the mounting holes according to the length.

Mounting Base

The mounting base fitted to the belt conveyor should be prepared before installation. When you are deciding the dimensions of the mounting base, refer to Product drawing.

Installation

Prepare the necessary installation frame according to the size of the belt conveyor frame

MAINTENANCE

Periodic Inspection

(1)Cleaning

Always clean when an excessive amount of dust accumulates on the touch roller.

(2)Action check

Check to see if the Pull Cord Switch is working normally by Pull the cord.

Lubrication

The Pull Cord Switch has no need to lubricate.

Tightening of Cover

When taking off the cover of Pull Cord Switch for the sake of writing, adjusting and checking, secure the screws of the cover after working, or the Pull Cord Switch may cause trouble due to water and dust entering from between the cover and casing.



Company Features
1. Guangdong Kaidi Energy Technology Co., Ltd. has built its reputation for manufacturing high quality , becoming one of the global manufacturers. Our professional equipment allows us to fabricate such .
2. We have a top R&D team to keep improving quality and design for our belt tear switch .
3. conveyor protection speed switch is assembled by our highly skilled professionals. Guangdong Kaidi Energy Technology Co., Ltd. deeply believes that customers are the source of long-term development for an enterprise. Please contact.
Kaidi Sensors conveyor protection speed switch is produced by our trained professionals using high-grade raw material according to industry norms.
Advanced production technology: belt tear switch is manufactured following the guidance of lean production method and completed by the combined efforts of advanced equipment and skilled workers.
The source of raw materials: before Kaidi Sensors belt tear switch comes out, it is processed from high quality raw materials. These materials are sourced from several different places within and out of the region.
Thanks to the team of diligent professionals, Kaidi Sensors conveyor protection speed switch is manufactured according to the requirement of lean production.
The improved design of Kaidi Sensors conveyor protection speed switch reduces quality problems from the source.
To ensure product quality, the product is produced under the supervision of our experienced quality assurance team.
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...