Abstract: The information on the installation requirements of pipeline
electromagnetic flowmeters is provided by excellent flowmeter and flowmeter manufacturers and quotation manufacturers. 1. Requirements for straight pipe sections In order to improve the influence of eddy current and flow field distortion, there are certain requirements for the length of the flowmeter installed in the front and rear straight pipe sections, otherwise it will affect the measurement accuracy (a speed flow device can also be installed, try to avoid the nearest After the regulating valve and half-open valve are installed. For more flowmeter manufacturers to select models and prices, you are welcome to inquire. The following is the details of the installation requirements for pipeline electromagnetic flowmeters. 1. The requirements for straight pipe sections are to improve the eddy current and flow field Due to the influence of distortion, there are certain requirements for the length of the flowmeter to be installed in the front and rear straight pipe sections, otherwise the measurement accuracy will be affected (a speed flow device can also be installed, try to avoid installing it after the nearest regulating valve and half-open valve). Installation Diagram Standard Pipe Type Front Straight Pipe L Rear Straight Pipe S Horizontal Pipe Drawing a 5D 3D Curve Drawing b 10D 5D Flaring Pipe Drawing c 5D 5D Valve Downstream Drawing d 10D 5D Shrinking Pipe Drawing e 5D 2D Pump Downstream Drawing f 15D 5D Mixed liquid diagram g 30D 3D 2. Requirements for process pipes The flowmeter has certain requirements for installation in the upstream and downstream process pipes, otherwise the measurement accuracy will be affected. a. The inner diameter of the upstream and downstream process pipes is the same as the inner diameter of the sensor, and should be Satisfaction: 0.98DN≤D≤1.05DN (in the formula, DN: the inner diameter of the sensor, D: the inner diameter of the process pipe) b. The process pipe and the sensor must be concentric, the coaxial deviation is not greater than 0.05DN3, and the requirements of the bypass channel In order to facilitate the maintenance of the flowmeter, it is best to install a side channel for the flowmeter. In addition, for heavily polluted fluids and flowmeters that need to be cleaned and the fluid cannot be stopped, a bypass channel must be installed. 4. According to the requirements of the flowmeter on the pipeline The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Installation Requirements for Pipeline
Electromagnetic Flow Meters'
level gauge are all following the most compatible manufacturing regulations.
If you are looking for customized level indicator level gauge, we have plenty of them in our store. We have customized level indicator and many others. Visit Kaidi level indicator to know more.
With innovative technology, our professionals can spend more time focused on strategies that will improve level gauge’s quality and deliver a more positive customers experience.
Undoubtedly, level gauge are made with advanced equipment.
What Guangdong Kaidi Energy Technology Co., Ltd. discovered was that innovation occurs when business models match up with one or more of the level gauge where technological advances overlap with market needs, thus resulting in growth and transformation.