Kaidi Sensors  >  AI - Page Sitemap  >  high-quality magnetrol guided wave radar level transmitter company for industrial
high-quality magnetrol guided wave radar level transmitter company for industrial

high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial
  • high-quality magnetrol guided wave radar level transmitter company for industrial

high-quality magnetrol guided wave radar level transmitter company for industrial

A quality audit will be carried out o Kaidi Sensors magnetrol guided wave radar level transmitter strictly. All textile fibers, chemical reagents or additives are carefully checked to ensure that any harmful chemicals are removed. It helps ease stress and pain caused by flat foot, plantar fasciitis, bunions, arthritis, metatarsal, etc
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

PRODUCT OVERVIEW

6GHz intelligent series radar level meter is suitable for non-contact continuous measurement of the level of liquid slurry, particle material and block material, suitable for large temperature and pressure changes;

The microwave pulse measurement method is used in the presence of inert gas and volatiles, and can work normally in the range of industrial frequency band. The beam energy is low, and can be installed in various metal and non-metal containers or pipelines, which does no harm to human body and the environment.


high-quality magnetrol guided wave radar level transmitter company for industrial-1


THE PRODUCT PRINCIPLE

Antenna system to launch and microwave receiving energy is very low, very short pulse. Radar waves travel with the speed of light. The running time can be through the electronic components are converted into a signal. Measurement of this special time extension method can realize stable, accurate in a very short period of time.

Even if the condition is very complex, the presence of false echo, with the latest micro- processing technology and debugging software also can analyze the level echo accurately.

high-quality magnetrol guided wave radar level transmitter company for industrial-2

Microwave antenna to receive the reflected pulse and transmitted to the electronic circuit, a microprocessor to signal processing, to identify the micro pulse generated on the material surface echo. Echo recognition is completed by the pulse system, the accuracy can reach millimeter level. From the material surface distance between D and T pulse is proportional to the time travel: D=C×T/2 Where C is the speed of light Because of the air tank is a known distance E, L: L=E-D By setting the empty tank height E (= zero), the full height of F (= full scale) and some application parameters, application parameters automatically makes the instrument to measure the environment. 4 - 20mA with a corresponding output.

PROTECTION GRADE

This instrument meets the protection class IP66/67 requirements, please ensure the waterproof cable sealing head. The following diagram:

high-quality magnetrol guided wave radar level transmitter company for industrial-3

How to install to meet the requirements of IP67: 

Please make sure that the sealing head is not damaged. 

Please make sure that the cable is not damaged. 

Please make sure that the cable for use with electrical connection specification. 

Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the① 

Tighten the cable seal head, see the② 

Please electrical interface will not use blind plug tight, see the

PRODUCT SPECIFICATION


high-quality magnetrol guided wave radar level transmitter company for industrial-4


APPEARANCE OF SIZE


high-quality magnetrol guided wave radar level transmitter company for industrial-5

TECHNICAL PARAMETERS

high-quality magnetrol guided wave radar level transmitter company for industrial-6

high-quality magnetrol guided wave radar level transmitter company for industrial-7

high-quality magnetrol guided wave radar level transmitter company for industrial-8


high-quality magnetrol guided wave radar level transmitter company for industrial-9

INSTALLATION REQUIREMENTS


high-quality magnetrol guided wave radar level transmitter company for industrial-10

 The recommended position (2), the outer wall of tank wall to install pipe shall 

meet the following from the tank wall best distance to tank diameter of 1/4 or 1/6, 

the minimum distance from the installation of tank wall as the measurement range of 1/10. 


For example: liquid level of storage tank 10mand the tank wall install the minimum distance of 1m.


Cannot be installed above the feeding port (4). 


Cannot be installed in the central position (3), if installed in the central, yield multiple false echo, clutter echo will lead to real signal loss. 


If you can't keep the instrument and the tank wall of the tank wall distance, the medium will adhesion caused by false echo, when debugging instrument should be false echo storage.


The top conical tank level, can be installed at the top of the tank is intermediate, 

can guarantee the measurement to the conical bottom. 


high-quality magnetrol guided wave radar level transmitter company for industrial-11high-quality magnetrol guided wave radar level transmitter company for industrial-12

A feed antenna to the vertical alignment surface. If the surface is rough, stack angle must be used to adjust the angle of Universal joint flange of the antenna to the alignment surface. 


(Due to the solid surface tilt will cause the echo attenuation, even Loss of signal.)


high-quality magnetrol guided wave radar level transmitter company for industrial-13

Tank installation instructions:


In the signal beam, should avoid the following installation: 

Such as: (1) the limit switch, temperature sensor. 

Symmetric devices such as (2): vacuum ring, a heating coil , Baffle plate etc. 

If the tank (1) (2) interference object, should be guided wave tube measurement.


Best installation options: 


Antenna size: larger antenna, beam angle smaller, interfering echoes will be weaker. 

Antenna adjustment: the antenna to adjust to the best measurement position.

Guided wave radar take over: The installation of the wave guide is used to avoid disturbing the echo.


Kaidi Sensors magnetrol guided wave radar level transmitter has gone through quality testing in a compulsory manner that is required for furniture. It is tested with the right testing machines that are well-calibrated to ensure the most reliable testing result. Reduced friction of this product helps prevent blisters
Kaidi Sensors magnetrol guided wave radar level transmitter will be tested strictly according to requirements. Its body frame, engine, mechanical components, and other parts will be tested to meet the highest safety and efficiency standards. It won’t easily crack, peel or fade
The design of Kaidi Sensors magnetrol guided wave radar level transmitter requires many skills. Except for basic knowledge such as Kinematics and Mechanisms, they also include Technical Drawing and Computer-Aided Engineering (CAE). This product has good air permeability
The manufacturing process of Kaidi Sensors magnetrol guided wave radar level transmitter covers a range of steps, mainly including designing, fabric pre-treating (cleaning and shrinking), fabric cutting, sewing, size finalizing, ironing, and packing. Ergonomically designed, it is comfortable to wear
The design of Kaidi Sensors magnetrol guided wave radar level transmitter is the application of various disciplines. They include mathematics, kinematics, statics, dynamics, mechanical technology of metals and engineering drawing. Its size can be fine-tuned to meet required needs
The product is believed to function timelessly with improved reliability and is expected to serve users for a long time without any defects. Its materials are safe to the human body and environmentally friendly
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...