Electrode routine maintenance of electromagnetic gauge

by:Kaidi Sensors     2022-07-17
Abstract: The daily maintenance information of the electrode of the electromagnetic meter is provided by the excellent flowmeter and flowmeter manufacturers. Electromagnetic flowmeter, electromagnetic flowmeter electrode should be cleaned regularly and cleaning method If the electromagnetic flowmeter measured medium is dirty for a long time, then after the electromagnetic flowmeter works for a period of time, the electrode will be fouled. When the conductivity of fouling substances. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the daily maintenance of the electrodes of the electromagnetic meter. Electromagnetic flowmeter, electromagnetic flowmeter electrodes should be cleaned regularly and cleaning method If the electromagnetic flowmeter measured medium is dirty for a long time, then after the electromagnetic flowmeter works for a period of time, there will be scaling on the electrode. When the conductivity of the fouling substance is different from the conductivity of the measured medium, it will bring measurement error. The adhesion of sludge and oil to the electrodes will also cause the output of the instrument to swing and drift. Therefore, in this case, we need to regularly maintain and clean the electromagnetic flowmeter electrodes. Let us introduce several methods for cleaning the electrodes of electromagnetic flowmeters for your reference. The commonly used methods for electrode cleaning are as follows: 1. Electrochemical methods Electrochemical phenomena exist in metal electrodes in electrolyte fluids. According to the principle of electrochemistry, there is an interfacial electric field between the electrode and the fluid, and the interface between the electrode and the fluid is caused by the electric double layer existing between the electrode/fluid phase. The study of the electric field at the interface between the electrode and the fluid found that the molecules, atoms or ions of the substance have enriched or poor adsorption at the interface, and found that most inorganic anions are surface active substances with a typical ion adsorption law, while the surface of inorganic cations activity is small. Therefore, electrochemical cleaning of electrodes only considers the case of anion adsorption. The adsorption of anions is closely related to the electrode potential, and the adsorption mainly occurs in the potential range that is more positive than the zero-charge potential, that is, the electrode surface with the opposite sign. On the electrode surface of the same charge, when the residual charge density is slightly larger, the electrostatic repulsion is greater than the adsorption force, and the anions are quickly desorbed, which is the principle of electrochemical cleaning. 2. Mechanical removal method The mechanical removal method realizes electrode removal by installing a special mechanical structure on the electrode. There are currently two forms: one is to use a mechanical scraper. A scraper with a thin shaft is made of stainless steel, and the scraper is drawn out through a hollow electrode. A mechanical seal is used between the thin shaft and the hollow electrode to prevent the outflow of the medium, so a mechanical scraper is formed. When the thin shaft is rotated from the outside, the scraper rotates against the plane of the electrode end to scrape off the dirt. This scraper can be used manually or automatically with a motor-driven thin shaft. Among the domestic electromagnetic flowmeters, the scraper-type electromagnetic flowmeter of Xi'an Yunyi has such performance, and the performance is stable and the operation is convenient. The other is in the tubular electrode, which is equipped with a wire brush for removing dirt, and the shaft is wrapped in a sealed“O”ring to prevent fluid leakage. This kind of cleaning device requires someone to frequently pull the wire brush to clean the electrode, which is not very convenient to operate. It is not as convenient as the scraper-type electromagnetic flowmeter of Xi'an Yunyi. 3. Cleaning method The ultrasonic voltage of 45~65kHz generated by the ultrasonic generator is applied to the electrode, so that the energy of the ultrasonic wave is concentrated on the contact surface between the electrode and the medium, so as to use the ability of ultrasonic wave to crush the dirt to achieve the purpose of cleaning. 4. Electric breakdown method This method uses alternating high-voltage electricity to be regularly added between the electrode and the medium, generally 30~100V. Because the electrode is attached, its surface contact resistance becomes larger, and the applied voltage is almost concentrated on the attached object. The high voltage will break down the attached object and then be washed away by the fluid. For overall safety, the use of electric breakdown method must be to clean the AC high voltage directly on the sensor signal output terminal when the flowmeter is interrupted for measurement, the signal line between the sensor and the converter is disconnected, and the power is cut off. The maintenance and cleaning methods of several electromagnetic flowmeter electrodes have been introduced above. In fact, if we can fully consider that the measuring medium will pollute the electrodes in the future, then we should choose a scraper type electromagnetic flowmeter, which can be very convenient. The maintenance and cleaning of the electrode can save a lot of trouble. Xi'an Yunyi scraper electromagnetic flowmeter is composed of display instrument, shell, upper coil, lower coil, electrode assembly, etc. The electrode assembly is a detachable scraper electrode structure. This structure is to put the signal electrode on the belt. On the scraper rod of the scraper, the signal electrode and the scraper rod are fixed in the electrode cup by the compression nut, the electrode cup is welded on the inner body, and the signal electrode is separated from the inner body, the electrode cup and the compression nut by insulating materials. Open; when the signal electrode needs to be maintained and maintained, just open the cover, turn the handle by hand, and drive the scraper rod to rotate, so that the scraper close to the signal electrode scrapes off the dirt on the surface of the signal electrode, and after cleaning, turn the scraper in the direction of rotation. To the direction of fluid flow (there is a direction mark on the knob), the operation is very convenient.
customized level indicator are required in the manufacture of almost every product and customized level indicator level gauge is one of the most common machines.
With all the pros and cons of different in mind, click Kaidi level indicator to learn more about and decide which level gauge option is best for your case.
The key to level gauge is understanding where there is a problem or need in certain markets and knowing how to solve it.
is something that has been around for a few decades now, enjoying it's heyday back in the customized level indicator.
Guangdong Kaidi Energy Technology Co., Ltd. harnesses science and technology to create products that support safer and healthier living and that enhance the overall quality of life.