Kaidi Sensors  >  AI - Page Sitemap  >  custom radar level measurement for business for transportation
custom radar level measurement for business for transportation

Custom radar level measurement for business for transportation

Outer Covering:
5-10 days
Process connection:
TT, Paypal, Credit card, Western union
Process temperature:
1 SET
Payments:
TT, Paypal, Credit card, Western union
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Product Information of custom radar level measurement for business for transportation
Company Advantages
1. The time and energy into designing radar level measurement proves to be efficient for the fame of KAIDI. Its power ratings can be customized e based on requests
2. Professional packing ensures that radar level measurement does not get damaged during transportation. This product is easy to install and use
3. This product can resist heat. The stainless-steel material has excellent high-temperature resistance and will not easily deform even baked at high temperature for a long time. It works stably under strong impact and vibration conditions
4. The product is not prone to deformation. Made from elastomeric materials, it is specially formulated to endure the application stresses to which it is subjected. This product is notable for its strong overload capacity

Characteristics of water conservancy industry application:

Ø  Radar level meter adopts a recommended industry emission frequency of 26GHz, so it has beam angle is small, concentrated energy, has stronger anti-interference ability and greatly improves the precision and reliability of measurement.

Ø  Small antenna size, easy to install and dustproof cover antenna protection device.

Ø  Light weight about 1KG, easy to install.

Ø  The measurement range of up to 70 meters, covering a large reservoir water level measurement.

Ø  With a variety of output circuit interface and data acquisition system.

Ø  The pulse working mode, radar level meter transmit power is very low, no harm to human body and environment.

908 :

ApplicationRivers, Lakes, Shoal
Measuring   Range: 30 meters
Process   ConnectionThread G1½ A /Frame /Flange
Process  Temperature -40 ~ 100
Process   Pressure:Normal pressure
Accuracy ± 3mm
Protection   GradeIP67 / IP65
Frequency   Range:26 GHz
The signal   Output:  RS485 / Modbus  ( 6~24V  DC) 4~20mA / Hart  Two  wire ( 24V DC) 
Power Supply   : (6 - 24V)   DC  / Four-wire    24V DC / Two  wire
The Scene   DisplayOptional
Outer Covering   : Aluminum /Plastic   /Stainless steel 
Outer   Covering: Aluminum /   Plastic /Single chamber



909 :

ApplicationRivers, Lakes, Shoal
Measuring   Range: 70 meters
Process   ConnectionThread G1½ A /Frame /Flange
Process  Temperature -40 ~ 100
Process   Pressure:Normal pressure
Accuracy ± 10mm
Protection   GradeIP67 / IP65
Frequency   Range:26 GHz
The signal   Output:  RS485 / Modbus  ( 6~24V  DC) 4~20mA / Hart  Two  wire ( 24V DC) 
Power Supply   : (6 - 24V)   DC  / Four-wire    24V DC / Two  wire
The Scene   DisplayOptional
Outer Covering   : Aluminum /Plastic   /Stainless steel 
Outer   Covering: Aluminum /   Plastic /Single chamber

custom radar level measurement for business for transportation-1


1.   Installation

l  Preparation before installation:

Ø  Please pay attention to the following matters, to ensure that the instrument can be installed correctly:

Ø  Please reserve enough space for installation.

Ø  Please avoid installing occasions strong vibration.

l  Illustration and installation position

Note: Radar antenna microwave pulse, have a certain emission angle. From the lower end of the antenna to be measured between the surface of the medium, and a transmitter shall be no obstruction in the region of the microwave beam radiation. Therefore, the installation should be avoided as far as possible shelter facilities, shall be carried out "false echo study" when necessary. Also note that when installing devices: the highest level measured shall enter blind; instrument must be connected to the earth, increasing the lightning protection measures; outdoor shade should be taken, rain measures.custom radar level measurement for business for transportation-2

Note: Radar antenna microwave pulse, have a certain emission angle. From the lower end of the antenna to be measured between the surface of the medium, and a transmitter shall be no obstruction in the region of the microwave beam radiation. Therefore, the installation should be avoided as far as possible shelter facilities, shall be carried out "false echo study" when necessary. Also note that when installing devices: the highest level measured shall enter blind; instrument must be connected to the earth, increasing the lightning protection measures; outdoor shade should be taken, rain measures.


2. The Electrical  Connection

Power Supply voltage


RS485 /   Modbuspower supply   and Modbus signal lines separated respectively using a shielded cable, the   power supply voltage range of see technical data.
(4~20)mA/HART   (Two wire system)       The   power supply and the output current signal sharing a two core shield cable.   The supply voltage range see technical data. For intrinsically safe type must   be a safety barrier between the power supply and the instrument.



Connection mode

l  The RS485/Modbus wiring diagram as follows:

custom radar level measurement for business for transportation-3

l  24V two wire wiring diagram as follows:

custom radar level measurement for business for transportation-4

Protection grade

This instrument meets the protection grade IP66/67 requirements,  please ensure the waterproof cable sealing head.

custom radar level measurement for business for transportation-5


How to install to meet the requirements of IP67:

Please make sure that the sealing head is not damaged.

Please make sure that the cable is not damaged.

Please make sure that the cable for use with electrical connection specification.

Cable into the electrical interface before its curved downward, ensure that the water will not flow into the shell, see the

Tighten the cable seal head, see the

Please electrical interface will not use blind plug tight, see the


3.   Structure  Size  (Unit: mm)

lThe Outer Covering:

custom radar level measurement for business for transportation-6

l  Appearance  size:

908 : 

custom radar level measurement for business for transportation-7

909 :

custom radar level measurement for business for transportation-8

 Connection 

²  Standard bracket

²  With rain cover bracket

²  Thread G1½ "A connection

²  G1½ mounting base connection

custom radar level measurement for business for transportation-9

4.   Technical   Parameters

The outer shell  
The seal between the shell and the shell cover                 Silicone rubber
Casing   window                                                                   Polycarbonate
The ground   terminal                                                           Stainless steel
The power supply voltage
Four wire   system(624) V DC / RS485    Modbus  / Power dissipation   90mW
Two wire   systemDC 24V /  4~20mA     / Power dissipation  0.75W
The cable parameters 
Cable entrance   / plug           1    M20xl.5 cable entrance

 1    blind plug
Terminal                               Conductor cross section1.0mm²  
Output parameters
The output signal                              RS485  Modbus    (6~24V  DC)
4~20mA /   Hart  Two  wire ( 24V DC)
Communication   protocol                  Modbus  control / HART
Resolution                                        1.6μA
Fault   signal                                       Constant current   output; 20. 5mA

22mA 

3.9mA
The integral   time                              (0 ~ 36) s,   adjustable
Blind   area                                 the ends of the   antenna
The maximum distance measurement      
90830 meters  
90970 meters  
 Microwave frequency                                              26GHz
The   measurement interval       about 1 second   (depending on the parameter settings)
Adjust the   time                         about 1 second   (depending on the parameter settings)
Display   resolution                   1 mm
Working storage and transportation temperature                          (-4070) 
Process temperature (the temperature of the antenna part   (-40100)
Pressure                                    Normal atmospheric   pressure
Seismic                                       Mechanical vibration   l0m/s², (10 ~ 150) Hz

Meter  Linearity

908 :


Emission angle                 Depending on the size of the antenna

-76mm                          12°

-96mm                          18°

Precision                          See chart


custom radar level measurement for business for transportation-10

909 :


Emission angle                 Depending on the size of the antenna

-76mm                          12°

-96mm                          18°

-121mm                         6°

Precision                          See chart

custom radar level measurement for business for transportation-11


Company Features
1. KAIDI still continues to make rapid progress in the radar level measurement industry.
2. Guangdong Kaidi Energy Technology Co., Ltd. has introduced sizable set of guided wave radar level manufacturing machines.
3. With our superb digital radar level meter , Guangdong Kaidi Energy Technology Co., Ltd. hopes to build relationships with you in the near future. Get quote!
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...