Abstract: The information on what to do when the
electromagnetic flowmeter is unstable when it is returned to zero is provided by the excellent flowmeter and flowmeter manufacturers and quotation manufacturers. The electromagnetic flowmeter produced by Weinan and Shunda flowmeter manufacturers is not affected by the temperature, pressure, density, viscosity and other parameters of the liquid when measuring the volume flow of the liquid, so the electromagnetic flowmeter is widely used in chemical industry, petroleum metallurgy, chemical industry fiber,. More flowmeter manufacturers select models and price quotations. You are welcome to inquire. The following is the article details on how to deal with the instability of the electromagnetic flowmeter. The electromagnetic flowmeter produced by the flowmeter manufacturer is not affected by the temperature, pressure, density, viscosity and other parameters of the liquid when measuring the volume flow of the liquid, so the electromagnetic flowmeter is widely used in chemical industry, petroleum metallurgy, chemical fiber, cement Manufacturing and other industrial production sectors. The following technologies will introduce the reasons and solutions for the instability of the electromagnetic flowmeter when it encounters zeroing: 1. The process of checking the instability of the zero-point electromagnetic flowmeter. Check the flow of the zero point electromagnetic flowmeter for instability. First, make a preliminary inspection and judgment according to the overall thinking of the process, and then carefully inspect and try to eliminate the faults one by one. The order of inspection items listed in the process is the one that can be inspected or understood without major operations, that is, easy first and then difficult. According to the past on-site inspection experience, the one with higher frequency and higher probability may appear in the future. Check the sequential requests you need. If it is confirmed by preliminary inspection that it is the cause of the latter faults, a detailed inspection can also be made in advance. 2. The pipeline is not filled with liquid or the liquid contains air bubbles. It is objectively considered that there is no activity in the flow sensor, but there is actually a small amount of activity. The main reasons for this type of failure are the poor airtightness of the shut-off valve of the pipeline, the small leakage detected by the electromagnetic flowmeter, and the misunderstanding of zero-point variation or zero-point instability. 3. It is often encountered that the valve has been used for a long time or the liquid is dirty so that the valve is not fully sealed, especially for large valves. Another common reason is that the
flow meter has several branch pipes in addition to the main pipeline, and the valves of these branch pipes are forgotten or neglected to be closed. Sometimes, it is more difficult to confirm that there is no activity in the management system on the spot. At this point, you can press to see if there is any leakage. 4. The conductivity of the liquid varies or is uneven, the zero point will change when it is still, and the output will shake when it is active. Therefore, the location of the flow meter should be far away from the injection point or the downstream of the chemical reaction section of the pipeline, and the flow sensor should preferably be installed upstream of these places. If the liquid contains solid phase, or impurities accumulate on the inner wall of the flow metering tube, or scale on the inner wall of the flow metering tube, or the electrode is contaminated by grease, etc., there may be a zero-point change. 5. Due to the fact that the scale on the inner wall and the outer surface of the electrode and the contamination level of the electrode cannot be completely the same and symmetrical, the equilibrium of the initial zero adjustment setting is destroyed. The active measure is to remove the dirt and the accumulation of scale layer; if the zero position does not change much, you can try to re-zero. 6. Changes in the state of the electrical equipment near the flow sensor (such as increased leakage current) constitute a change in ground potential, which will also cause a change in the zero point of the electromagnetic flowmeter. The influence of external interference such as pipeline stray current mainly depends on the good grounding maintenance of the electromagnetic flowmeter. Generally, the grounding resistance is required to be less than 10, and the grounding should not be shared with other electrical appliances. Sometimes the environmental conditions are good, and the electromagnetic flowmeter can work normally without grounding, but once the good environment does not exist, the instrument will appear faulty, and it will bring a lot of trouble to check again at that time. 7. Check the flow chart. The insulation drop of the signal circuit will cause the zero point instability. The main reason for the insulation drop of the signal circuit is caused by the insulation drop of the electrode part, but the insulation drop or damage of the signal cable and its wiring terminals cannot be eliminated. Be careful, full of moisture acid mist or powder dust intrusion into the instrument junction box or cable protection layer, so that the insulation falls. 8. Check the insulation resistance of the signal loop and stop at the two parts of the cable side and the flow sensor respectively, and test with a megohmmeter. Since the signal cable is easy to detect, it can be done first. Filled with liquid electromagnetic flow measuring electrode surface contact resistance and empty pipe flow measuring electrode insulation resistance. Flowmeter manufacturers have been“Technology guarantees quality, innovation promotes development, and integrity weaves the future”, adhering to its own firm belief, and created a development path suitable for its own characteristics. Looking back, we firmly believe that,“factory”The future of our company is bound to be a sunny avenue full of flowers and smiling faces! The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our manufacturer. 'What should I do if the electromagnetic flow meter is unstable when returning to zero'
There are a wide variety of which are scientifically tested to have positive effects on the ability to customized level indicator. customized level indicator level gauge is one of them.
Interested in the that create such effect? Come to Kaidi level indicator to see some items.
Based on the level gauge, here are the top compliance challenges businesses face, and what you can do to make them easier on ourselves.
The first step toward KAIDI’s successful selling campaign is to understand your customers. What are their needs or desires? Why would they support your product? Even more importantly, why would they be passionate about your product?