The main method of cleaning the electrode of the electromagnetic flowmeter ingeniously

by:Kaidi Sensors     2022-09-05
Abstract: The information on the main methods of cleverly cleaning the electrodes of the electromagnetic flowmeter meter is provided by the excellent flowmeter and flowmeter manufacturers and quotation manufacturers. If the medium measured by the electromagnetic flowmeter is relatively dirty for a long time, after the electromagnetic flowmeter works for a period of time, scaling will occur on the electrodes. When the conductivity of the fouling substance is different from the conductivity of the measured medium, it will bring measurement error. Sludge, oil. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is an introduction to the main methods of ingeniously cleaning the electrodes of electromagnetic flowmeters. If the medium measured by the electromagnetic flowmeter is relatively dirty for a long time, after the electromagnetic flowmeter works for a period of time, scaling will occur on the electrodes. When the conductivity of the fouling substance is different from the conductivity of the measured medium, it will bring measurement error. The adhesion of sludge and oil to the electrodes will also cause the output of the instrument to swing and drift. Therefore, in this case, we need to regularly maintain and clean the electromagnetic flowmeter electrodes. 1. For inorganic pollution, the electrode can be immersed in 0.1mol/L dilute hydrochloric acid for 30 minutes, washed with pure water, and then immersed in 3.5MOL/L potassium chloride solution for 6 hours before use. 2. Immerse in 4% hydrogen fluoride solution for 3~5s, take out and rinse with distilled water, then soak in 0.1mol/L hydrochloric acid solution for several hours, rinse with distilled water, and calibrate. 3. The surface of platinum is seriously polluted and an oxide film is formed. The platinum or gold surface can be polished with toothpaste, then washed with pure water, and then immersed in 3.5MOL/L potassium chloride solution for 6 hours before use. 4. For organic oil pollution and oil film pollution, the platinum or gold surface can be cleaned with detergent, then washed with pure water, and then immersed in 3.5MOL/L potassium chloride solution for 6 hours before use. Electromagnetic flowmeter electrode cleaning methods are as follows: 1. Electrochemical method Electrochemical phenomenon exists in the metal electrode in the electrolyte fluid. According to the principle of electrochemistry, there is an interfacial electric field between the electrode and the fluid, and the interface between the electrode and the fluid is caused by the electric double layer existing between the electrode/fluid phase. The study of the electric field at the interface between the electrode and the fluid found that the molecules, atoms or ions of the substance have enriched or poor adsorption at the interface, and found that most inorganic anions are surface active substances with a typical ion adsorption law, while the surface of inorganic cations activity is small. Therefore, electrochemical cleaning of electrodes only considers the case of anion adsorption. The adsorption of anions is closely related to the electrode potential, and the adsorption mainly occurs in the potential range that is more positive than the zero-charge potential, that is, the electrode surface with the opposite sign. On the electrode surface of the same charge, when the residual charge density is slightly larger, the electrostatic repulsion is greater than the adsorption force, and the anions are quickly desorbed, which is the principle of electrochemical cleaning. 2. Mechanical removal method The mechanical removal method is to realize electrode removal by installing a special mechanical structure on the electrode of the electromagnetic flowmeter. There are currently two forms: one is to use a mechanical scraper. A scraper with a thin shaft is made of stainless steel, and the scraper is drawn out through a hollow electrode. A mechanical seal is used between the thin shaft and the hollow electrode to prevent the outflow of the medium, so a mechanical scraper is formed. When the thin shaft is rotated from the outside, the scraper rotates against the plane of the electrode end to scrape off the dirt. This scraper can be used manually or automatically with a motor-driven thin shaft. Among the domestic electromagnetic flowmeters, the scraper-type electromagnetic flowmeter of Xi'an Yunyi has such performance, and the performance is stable and the operation is convenient. The other is in the tubular electrode, which is equipped with a wire brush for removing dirt, and the shaft is wrapped in a sealed“O”ring to prevent fluid leakage. This kind of cleaning device requires someone to frequently pull the wire brush to clean the electrode, which is not very convenient to operate. It is not as convenient as the scraper-type electromagnetic flowmeter of Xi'an Yunyi. 3. The ultrasonic cleaning method applies the ultrasonic voltage of 45~65kHz generated by the ultrasonic generator to the electrode, so that the energy of the ultrasonic wave is concentrated on the contact surface between the electrode and the medium, so as to use the ability of the ultrasonic wave to crush the dirt to achieve the purpose of cleaning. 4. Electric breakdown method This method uses alternating high-voltage electricity to be regularly added between the electrode and the medium, generally 30~100V. Because the electrode is attached, its surface contact resistance becomes larger, and the applied voltage is almost concentrated on the attached object. The high voltage will break down the attached object and then be washed away by the fluid. For overall safety, the use of electric breakdown method must be to clean the AC high voltage directly on the sensor signal output terminal when the flowmeter is interrupted for measurement, the signal line between the sensor and the converter is disconnected, and the power is cut off. The maintenance and cleaning methods of several electromagnetic flowmeter electrodes have been introduced above. In fact, if we can fully consider that the measuring medium will pollute the electrodes in the future, then we should choose a scraper type electromagnetic flowmeter, which can be very convenient. The maintenance and cleaning of the electrode can save a lot of trouble. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Introduction to the main methods of cleverly cleaning the electrodes of electromagnetic flowmeters'
KAIDI saves time and increases productivity because it's one of the most complete sources of business and contact information.
Guangdong Kaidi Energy Technology Co., Ltd. offers the best products, high-quality services and innovative technology.
There are ample scientific evidence of reducing the risk of customized level indicator.
We attach a great importance to domestic market and knows the importance factors of manufacturing level gauge, such as producing methods, etc.
Although the core manufacturing factor of level gauge is high technology, smart customers know that we need to enhance our material quality and producing standard.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...